Publications by authors named "Alexander M Kress"

Purpose: Bone loss around uncemented femoral components is suspected to precede implant loosening and contribute to problems in revision surgery. Short-stemmed cementless femoral components are designed to preserve proximal femoral bone stock and ultimately the longevity of the prosthesis.

Methods: With quantitative computed tomography-assisted osteodensitometry, we prospectively analyzed femoral cortical and cancellous bone density (BD) and contact area changes of an uncemented collum femoris preserving stem (n = 38) 10 days, 1, 3 and 7 years post-operatively.

View Article and Find Full Text PDF

The impact of total hip arthroplasty on strain adaptive bone remodeling has been extensively analyzed by dual-energy x-ray absorptiometry. In this study, we present a prospective computed tomography-assisted study of periacetabular cortical and cancellous bone mineral density (in milligrams of calcium hydroxyapatite [CaHA] per milliliter, or mgCaHA/mL) changes 10 days and 1, 3, and 7 years after press-fit cup implantation for 38 hips in vivo. Cancellous bone mineral density decreased by Ø -63% ventral and Ø -85% dorsal to the cup; cortical bone mineral density, by Ø -22% ventral and Ø -18% dorsal to the cup.

View Article and Find Full Text PDF

Background: As a follow-up of a previously reported three-year study, we analyzed the periprosthetic acetabular cortical and cancellous bone density changes at ten years after implantation of a press-fit cup.

Methods: Prospective clinical, radiographic, and quantitative computed tomography examinations were performed within ten days and at mean periods of one, three, and ten years after total hip arthroplasty with a press-fit cup, a femoral stem with a tapered design, and alumina-alumina pairing. Periacetabular cortical and cancellous bone density (mg CaHA/mL) in the cranial, ventral, and dorsal regions about the cup were measured for twenty-four hips in vivo.

View Article and Find Full Text PDF

Ceramic-on-ceramic coupling is thought to be a durable alternative to metal- or alumina-on-polyethylene pairing. No evidence exists suggesting superior clinical and radiological results for hydroxyapatite-coated stems versus uncoated stems. The aim of this study is to report the performance of an alumina-on-alumina bearing cementless total hip arthroplasty and to compare stems with a tapered design with and without hydroxyapatite coating.

View Article and Find Full Text PDF

Aim: Tissue sparing hip prostheses are becoming more and more popular especially for the treatment of younger patients. The objective of this study was to evaluate the clinical and radiological results after insertion of a tissue sparing hip prosthesis.

Method: In 47 consecutive non-selected patients (50 hips), the clinical and radiographic results of cementless total hip arthroplasty using a collum femoris preserving stem, a pressfit cup and an alumina-polyethylene pairing were prospectively evaluated.

View Article and Find Full Text PDF