Publications by authors named "Alexander Hyhlik-Duerr"

Purpose: The PowerGlide Pro™ Midline Catheter is a peripheral venous access device with a length of 8-10 cm, allowing the tip to reach far into the venous system. The aim of this study was to evaluate the dwell time of the catheter. Secondary endpoints included suitability for specific medications (e.

View Article and Find Full Text PDF

Background: Beyond a certain threshold diameter, abdominal aortic aneurysms (AAA) are to be treated by open surgical or endovascular aortic aneurysm repair (EVAR). In a quarter of patients who undergo EVAR, inversion of blood flow in the inferior mesenteric artery or lumbar arteries may lead to type II endoleak (T2EL), which is associated with complications (e.g.

View Article and Find Full Text PDF

Purpose: Aim of this study was to analyze hospitalizations due to ruptured and non-ruptured abdominal aortic aneurysms (rAAA, nrAAA) in Germany between 2005 and 2021 to determine long-term trends in treatment and the impact of the SARS-CoV-2 pandemic.

Materials And Methods: Fully anonymized data were available from the research data center (RDC) of the German Federal Statistical Office (Destatis). All German hospitalizations with the ICD-10 code "I71.

View Article and Find Full Text PDF

Background: To evaluate longer-term results of a cohort treated with primary chimney endovascular aneurysm sealing (ChEVAS) for complex abdominal aortic aneurysms or secondary ChEVAS after failed endovascular aneurysm repair/endovascular aneurysm sealing.

Methods: A single-center study was conducted of 47 consecutive patients (mean age 72 ± 8 years, range 50-91; 38 men) treated with ChEVAS from February 2014 to November 2016 and followed through December 2021. The main outcome measures were all-cause mortality (ACM), aneurysm-related mortality, occurrence of secondary complications and conversion to open surgery.

View Article and Find Full Text PDF

Objectives: An aberrant right subclavian artery (ARSA) is one of the most common anatomic variants of the aortic arch. The combination of an ARSA and a transection is naturally rare.

Methods: This case report describes the treatment of a transection in the presence of an ARSA and the follow-up of two years.

View Article and Find Full Text PDF

Background: The risk of thromboembolic events is increased for coronavirus disease (COVID)-19 inpatients. For severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-infected outpatients, only few data are available so far.

Methods: In our prospective single-center study, 461 SARS-CoV-2-infected outpatients were screened for the presence of deep vein thrombosis.

View Article and Find Full Text PDF

In this article, we present a method to determine the influence of meteorology and air pollutants on ruptured aortic aneurysm (rAA). In contrast to previous studies, our work takes into account highly resolved seasonal relationships, a time-lagged effect relationship of up to two weeks, and furthermore, potential confounding influences between the meteorological and air-hygienic variables are considered and eliminated using a cross-over procedure. We demonstrate the application of the method using the cities of Augsburg and Munich in southern Germany as examples, where a total of 152 rAA can be analyzed for the years 2010-2019.

View Article and Find Full Text PDF

Purpose: Intraoperative injury to the popliteal artery is a rare complication of orthopedic surgery, however, it can have serious consequences, including major amputation. Recommendations for a standard approach are lacking. The aim of this study was to develop an interdisciplinary therapeutic algorithm to assist in complication management.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess how the COVID-19 pandemic affected urgent and elective thoracic and abdominal aortic surgeries between January-May 2020 and the same period in 2019.
  • Researchers found no significant change in the number of urgent procedures, but there was a notable 35% drop in elective surgeries during the pandemic, especially in countries like Italy.
  • Patients with acute conditions still sought treatment, indicating that while elective cases decreased, emergency cases were managed as per the guidelines, warranting further investigation into the long-term effects of delayed elective surgeries.
View Article and Find Full Text PDF

Purpose: To evaluate the technical features and clinical results after open conversion for complications following endovascular aneurysm sealing (EVAS).

Materials And Methods: From July 2013 to February 2020, 44 patients (mean age 72±8 years; 36 men) underwent an open conversion due to EVAS complications in a single center. Data were collected on patient characteristics, reasons for conversion, characteristics and duration of the procedure, condition of the polymer, blood loss, time in the intensive care unit (ICU), and intra/postoperative complications.

View Article and Find Full Text PDF

Background: The 1-year results of the use of the Nellix (Endologix Inc, Irvine, Calif) endovascular aneurysm sealing (EVAS) device were initially promising. However, midterm complications including migration and aneurysm growth occurred more frequently than expected, which provided an incentive to refine the instructions for use. Strategies for the management of complications arising after endovascular aneurysm repair are often not applicable for EVAS, given the unique configuration of the Nellix device, and new techniques are needed.

View Article and Find Full Text PDF