Magnesium batteries have attracted great attention as an alternative to Li-ion batteries but still suffer from limited choice of positive electrode materials. VO exhibits high theoretical capacities, but previous studies have been mostly limited to α-VO. Herein, we report on the β-VO polymorph as a Mg intercalation electrode.
View Article and Find Full Text PDFObjectives: The aim of this study is to assess the course and management of poorly differentiated bladder urothelial carcinoma (UC), including plasmacytoid UC (PUC), in our local area. Although bladder cancer is relatively common, PUC is a rare and aggressive subtype with a poor prognosis that is still poorly understood.
Materials And Methods: A retrospective assessment of all poorly differentiated high-grade UC over the last 15 years (2005-2020) in the Hunter New England area was completed.
Vascular access is the lifeline for hemodialysis patients and the single most important component of the hemodialysis procedure. Arteriovenous fistula (AVF) is the preferred vascular access for hemodialysis patients, but nearly 60% of AVFs created fail to successfully mature due to early intimal hyperplasia development and poor outward remodeling. There are currently no therapies available to prevent AVF maturation failure.
View Article and Find Full Text PDFLayered 2D (PbI ) (BiI ) materials exhibit a nonlinear dependence in structural and charge transport properties unanticipated from the combination of PbI and BiI . Within (PbI ) (BiI ) crystals, phase integration yields deceptive structural features, while phase boundary separation leads to new conductance switching behavior observed as large peaks in current during current-voltage (I-V) measurements (±100 V). Temperature- and time-dependent electrical measurements demonstrate that the behavior is attributed to ionic transport perpendicular to the layers.
View Article and Find Full Text PDFHemorrhagic blood loss from traumatic injury is the leading cause of death in severe accidents and combat injuries. Treating and stopping blood loss in a timely and effective manner is essential for the survival of the patient. Currently, QuikClot and dry fibrin sealant dressing are well-known approaches for hemostatic treatment.
View Article and Find Full Text PDFInserting a graft into vessels with different diameters frequently causes severe damage to the host vessels. Poor flow patency is an unresolved issue in grafts, particularly those with diameters less than 6 mm, because of vessel occlusion caused by disturbed blood flow following fast clotting. Herein, successful patency in the deployment of an ≈2 mm diameter graft into a porcine vessel is reported.
View Article and Find Full Text PDFObjectives: To compare the quality of electroencephalography (EEG) signals recorded with a rapid response EEG system and the signals recorded with conventional clinical EEG recordings.
Methods: We studied the differences between EEG recordings taken with a rapid response EEG system (Ceribell) compared to conventional EEG through two separate set of studies. First, we conducted simultaneous recording on a healthy subject in an experimental laboratory setting where the rapid response EEG and two conventional EEG recording systems (Nihon Kohden and Natus) were used at the same time on the same subject using separate but adjacently placed electrodes.
IEEE Trans Radiat Plasma Med Sci
September 2018
Hybrid positron emission tomography (PET)/magnetic resonance imaging (MRI) has risen to the cutting edge of medical imaging technology as it allows simultaneous acquisition of structural, functional and molecular information of the patient. A PET insert that can be installed into existing MR systems can in principle reduce the cost barriers for an existing MR site to achieve simultaneous PET/MRI compared to procuring an integrated PET+MRI system. The PET insert systems developed so far for PET/MRI require the RF transmitter coil to reside inside the PET ring as those PET inserts block the RF fields from the MRI system.
View Article and Find Full Text PDFCardiovascular disease is the number one cause of death in the U.S and results in the loss of approximately one million lives and more than 400 billion U.S.
View Article and Find Full Text PDFTo date, bone tissue regeneration strategies lack an approach that effectively provides an osteogenic and angiogenic environment conducive to bone growth. In the current study, we evaluated the osteogenic and angiogenic response of human mesenchymal stem cells (hMSCs) and green fluorescent protein-expressing human umbilical vein endothelial cells (GFP-HUVECs) cocultured on a self-assembled, peptide amphiphile nanomatrix functionalized with the cell adhesive ligand RGDS (PA-RGDS). Analysis of alkaline phosphatase activity, von Kossa staining, Alizarin Red quantification, and osteogenic gene expression, indicates a significant synergistic effect between the PA-RGDS nanomatrix and coculture that promoted hMSC osteogenesis.
View Article and Find Full Text PDFBackground: The Accident and Emergency Department (A&E) is a busy environment that requires time- and resource-efficient teaching. Managing cervical spine (c-spine) trauma is often an unfamiliar skill for new doctors starting work in A&E. This study investigated the efficacy of brief teaching interventions in changing clinician behaviour within A&E.
View Article and Find Full Text PDFDespite the great promise of integrated positron emission tomography (PET)/magnetic resonance (MR) imaging to add molecular information to anatomical and functional MR, its potential impact in medicine is diminished by a very high cost, limiting its dissemination. An RF-penetrable PET ring that can be inserted into any existing MR system has been developed to address this issue. Employing optical signal transmission along with battery power enables the PET ring insert to electrically float with respect to the MR system.
View Article and Find Full Text PDFThe unusual Au ternary halide AuPbI has been isolated from reactions of AuI, PbI, and I. AuPbI crystallizes in the triclinic P1̅ space group as micron-scale needles with cell dimensions a = 4.5170(3) Å, b = 7.
View Article and Find Full Text PDFOpioid-induced constipation has a negative impact on quality of life for patients with chronic pain and can affect more than a third of patients. A related but separate entity is postoperative ileus, which is an abnormal pattern of gastrointestinal motility after surgery. Nonselective μ-opioid receptor antagonists reverse constipation and opioid-induced ileus but cross the blood-brain barrier and may reverse analgesia.
View Article and Find Full Text PDFBackground: Multimodal analgesia featuring peripheral nerve blocks decreases postoperative pain for patients undergoing primary total knee arthroplasty (TKA). Many anesthesiologists and surgeons advocate for the use of adductor canal blocks (ACBs) for analgesia, which result in less weakness compared to femoral nerve blocks. Few data exist to guide analgesic management in total knee revision (TKR), considered to be more painful than primary TKA.
View Article and Find Full Text PDFPurpose: A brain sized radio frequency (RF)-penetrable PET insert has been designed for simultaneous operation with MRI systems. This system takes advantage of electro-optical coupling and battery power to electrically float the PET insert relative to the MRI ground, permitting RF signals to be transmitted through small gaps between the modules that form the PET ring. This design facilitates the use of the built-in body coil for RF transmission and thus could be inserted into any existing MR site wishing to achieve simultaneous PET/MR imaging.
View Article and Find Full Text PDFBackground: Chronic rhinosinusitis (CRS) is often associated with persistent bacterial infection despite the use of systemic antibiotics. Topically administered antibiotics are an alternative strategy, but require effective local concentrations, prolonged mucosal contact time, minor systemic absorption, and minimal depletion. The objectives of the current study were to analyze the in vitro release rate and in vivo drug delivery tolerance and pharmacokinetics of a ciprofloxacin-coated sinus stent (CSS).
View Article and Find Full Text PDFUnlabelled: For three-dimensional tissue engineering scaffolds, the major challenges of hydrogels are poor mechanical integrity and difficulty in handling during implantation. In contrast, electrospun scaffolds provide tunable mechanical properties and high porosity; but, are limited in cell encapsulation. To overcome these limitations, we developed a "hybrid nanosack" by combination of a peptide amphiphile (PA) nanomatrix gel and an electrospun poly (ε-caprolactone) (ePCL) nanofiber sheet with porous crater-like structures.
View Article and Find Full Text PDFPurpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study.
View Article and Find Full Text PDFInflammatory responses play a critical role in tissue-implant interactions, often limiting current implant utility. This is particularly true for cardiovascular devices. Existing stent technology does little to avoid or mitigate inflammation or to influence the vasomotion of the artery after implantation.
View Article and Find Full Text PDF