Int J Cardiovasc Imaging
December 2024
To evaluate dual-layer dual-energy computed tomography (dlDECT)-based characterization of thrombus composition for differentiation of acute pulmonary embolism (PE) and chronic thromboembolic pulmonary hypertension (CTEPH). This retrospective single center cohort study included 49 patients with acute PE and 33 patients with CTEPH who underwent CT pulmonary angiography on a dlDECT from 06/2016 to 06/2022. Conventional images), material specific images (virtual non-contrast [VNC], iodine density overlay [IDO], electron density [ED]), and virtual monoenergetic images (VMI) were analyzed.
View Article and Find Full Text PDFObjectives: Coronary CT angiography (CCTA) is becoming increasingly important in the workup of coronary artery disease. Imaging of stents and in-stent stenoses remains a challenge. This work investigates the assessability of in-stent stenoses in photon counting CT (PCCT) using ultra-high-resolution (UHR) imaging and optimized reconstruction kernels.
View Article and Find Full Text PDFPurpose: Augmented reality navigation in liver surgery still faces technical challenges like insufficient registration accuracy. This study compared registration accuracy between local and external virtual 3D liver models (vir3DLivers) generated with different rendering techniques and the use of the left vs right main portal vein branch (LPV vs RPV) for landmark setting. The study should further examine how registration accuracy behaves with increasing distance from the ROI.
View Article and Find Full Text PDFAims: Non-ischaemic cardiomyopathy (NICMP), an incurable disease terminating in systolic heart failure (heart failure with reduced ejection fraction [HFrEF]), causes immune activation, however anti-inflammatory treatment strategies so far have failed to alter the course of this disease. Myeloperoxidase (MPO), the principal enzyme in neutrophils, has cytotoxic, pro-fibrotic and nitric oxide oxidizing effects. Whether MPO inhibition ameliorates the phenotype in NICMP remains elusive.
View Article and Find Full Text PDFBackground: Diagnosing myocarditis relies on multimodal data, including cardiovascular magnetic resonance (CMR), clinical symptoms, and blood values. The correct interpretation and integration of CMR findings require radiological expertise and knowledge. We aimed to investigate the performance of Generative Pre-trained Transformer 4 (GPT-4), a large language model, for report-based medical decision-making in the context of cardiac MRI for suspected myocarditis.
View Article and Find Full Text PDFBackground Errors in radiology reports may occur because of resident-to-attending discrepancies, speech recognition inaccuracies, and large workload. Large language models, such as GPT-4 (ChatGPT; OpenAI), may assist in generating reports. Purpose To assess effectiveness of GPT-4 in identifying common errors in radiology reports, focusing on performance, time, and cost-efficiency.
View Article and Find Full Text PDFFront Cardiovasc Med
November 2023
Aim: The purpose of this study was to investigate the clinical application of Compressed SENSE accelerated single-breath-hold LGE with 3D isotropic resolution compared to conventional LGE imaging acquired in multiple breath-holds.
Material & Methods: This was a retrospective, single-center study including 105 examinations of 101 patients (48.2 ± 16.
Objectives: To evaluate dual-layer dual-energy computed tomography (dlDECT)-derived pulmonary perfusion maps for differentiation between acute pulmonary embolism (PE) and chronic thromboembolic pulmonary hypertension (CTEPH).
Methods: This retrospective study included 131 patients (57 patients with acute PE, 52 CTEPH, 22 controls), who underwent CT pulmonary angiography on a dlDECT. Normal and malperfused areas of lung parenchyma were semiautomatically contoured using iodine density overlay (IDO) maps.
Background: While computed tomography pulmonary angiography (CTPA) is an integral part of the work-up in patients with suspected pulmonary hypertension (PH), there is no established CTPA-derived prognostic marker. We aimed to assess whether quantitative readouts of lung vessel morphology correlate with established prognostic indicators in PH.
Methods: We applied a fully-automatic in-house developed algorithm for segmentation of arteries and veins to determine lung vessel morphology in patients with precapillary PH who underwent right heart catheterization and CTPA between May 2016 and May 2019.
Objective: To compare the measurement of aortic diameters using a novel flow-independent MR-Angiography (3D modified Relaxation-Enhanced Angiography without Contrast and Triggering (modified REACT)) and transthoracic echocardiography (TTE) in Marfan syndrome (MFS) patients.
Material And Methods: This retrospective, single-center analysis included 46 examinations of 32 MFS patients (mean age 37.5 ± 11.
Purpose: Imaging stents and in-stent stenosis remains a challenge in coronary computed tomography angiography (CCTA). In comparison to conventional Computed Tomography, Photon Counting CT (PCCT) provides decisive clinical advantages, among other things by providing low dose ultra-high resolution imaging of coronary arteries. This work investigates the image quality in CCTA using clinically established kernels and those optimized for the imaging of cardiac stents in PCCT, both for in-vitro stent imaging in 400 μm standard resolution mode (SRM) and 200 μm Ultra High Resolution Mode (UHR).
View Article and Find Full Text PDFBackground: Left atrial outpouching structures such as left atrial diverticula (LADs) and left-sided septal pouches (LSSPs) might be a source of cryptogenic stroke. This imaging study evaluates the association between pouch morphology, patient comorbidities and ischemic brain lesions (IBLs).
Methods: This is a retrospective single-center analysis of 195 patients who received both a cardiac CT and a cerebral MRI.
Objectives: To compare the incidence of persistent air leak (PAL) following cryoablation vs MWA of lung tumors when the ablation zone includes the pleura.
Methods: This bi-institutional retrospective cohort study evaluated consecutive peripheral lung tumors treated with cryoablation or MWA from 2006 to 2021. PAL was defined as an air leak for more than 24 h after chest tube placement or an enlarging postprocedural pneumothorax requiring chest tube placement.
Purpose: The purpose of the study was to evaluate the midterm and long-term outcomes of patients who underwent thoracic endovascular aortic repair (TEVAR) procedure to treat an uncomplicated acute and subacute type B aortic dissection (uATBAD) with high risk for subsequent aortic complications compared with the group of patients who received a conservative treatment protocol during the same period.
Materials And Methods: Between 2008 and 2019, 35 patients who had TEVAR due to uATBAD and those with conservative procedure (n=18) were included in a retrospective analysis and follow-up study. The primary endpoints were false lumen thrombosis/perfusion, true lumen diameter, and aortic dilatation.
Background: Structured reporting allows a high grade of standardization and thus a safe and unequivocal report communication. In the past years, the radiological societies have started several initiatives to base radiological reports on structured reporting rather than free text reporting.
Methods: Upon invitation of the working group for Cardiovascular Imaging of the German Society of Radiology, in 2018 an interdisciplinary group of Radiologists, Cardiologists, Pediatric Cardiologists and Cardiothoracic surgeons -all experts on the field of cardiovascular MR and CT imaging- met for interdisciplinary consensus meetings at the University Hospital Cologne.
Background: Chronic thromboembolic pulmonary hypertension (CTEPH) is considered a complication of pulmonary embolism (PE). However, signs of CTEPH may exist in patients with a first symptomatic PE.
Research Question: Which radiologic findings on CT pulmonary angiography (CTPA) at the time of acute PE could indicate the presence of preexisting CTEPH?
Study Design And Methods: This study included unselected patients with acute PE who were prospectively followed up for 2 years with a structured visit schedule.
Introduction: Recombinant adenoviral vector vaccines against severe acute respiratory syndrome coronavirus 2 have been observed to be associated with vaccine-induced immune thrombotic thrombocytopenia. Though vaccine-induced immune thrombotic thrombocytopenia is a rare complication after vaccination with recombinant adenoviral vector vaccines, it can lead to severe complications. In vaccine-induced immune thrombotic thrombocytopenia, the vector vaccine induces heparin-independent production of platelet factor 4 autoantibodies, resulting in platelet activation and aggregation.
View Article and Find Full Text PDFObjective: Due to reversal blood flow in the diastolic phase, outpouchings at the aortic isthmus may carry the risk of thrombus formation and subsequent thromboembolism. The objective was to evaluate the association between aortic ductus diverticula (ADDs) and ischemic brain alterations in cerebral magnetic resonance imaging.
Methods: A retrospective analysis of 218 patients who received both a dedicated computed tomography angiography of the thoracic aorta and a brain magnetic resonance imaging was performed.
Front Cardiovasc Med
February 2022
Objectives: To evaluate the usefulness of spectral detector CT (SDCT)-derived pulmonary perfusion maps and pulmonary parenchyma characteristics for the semiautomated classification of pulmonary hypertension (PH).
Methods: A total of 162 consecutive patients with right heart catheter (RHC)-proven PH of different aetiologies as defined by the current ESC/ERS guidelines who underwent CT pulmonary angiography (CTPA) on SDCT and 20 patients with an invasive rule-out of PH were included in this retrospective study. Semiautomatic lung segmentation into normal and malperfused areas based on iodine density (ID) as well as automatic, virtual non-contrast-based emphysema quantification were performed.
Background: To evaluate whether volumetric iodine quantification of the lung allows for the automatic identification of patients with chronic thromboembolic pulmonary hypertension (CTEPH) and whether the extent of pulmonary malperfusion correlates with invasive hemodynamic parameters.
Methods: Retrospective data base search identified 30 consecutive patients with CTEPH who underwent CT pulmonary angiography (CTPA) on a spectral-detector CT scanner. Thirty consecutive patients who underwent an identical CT examination for evaluation of suspected acute pulmonary embolism and had no signs of pulmonary embolism or PH, served as control cohort.
Background: 4D flow imaging can be used to evaluate vortex formation in the pulmonary artery seen in patients with pulmonary hypertension. We evaluated if a k-t accelerated multi-VENC (velocity encoding) 4D flow acquisition improves image quality, inter-reader agreement and correlation with hemodynamic parameters.
Methods: A total of 14 patients with pulmonary hypertension (5 females, 9 males; mean age 61 ± 16 years) underwent 4D flow MRI (magnetic resonance imaging) and right heart catheterization.
Objective: Liver cancer is one of the most commonly diagnosed cancer, and energy-based tumor ablation is a widely accepted treatment. Automatic and robust segmentation of liver tumors and ablation zones would facilitate the evaluation of treatment success. The purpose of this study was to develop and evaluate an automatic deep learning based method for (1) segmentation of liver and liver tumors in both arterial and portal venous phase for pre-treatment CT, and (2) segmentation of liver and ablation zones in both arterial and portal venous phase for after ablation treatment.
View Article and Find Full Text PDFBackground: Phase contrast magnetic resonance imaging, PC MRI, is a valuable tool allowing for non-invasive quantification of CSF dynamics, but has lacked adoption in clinical practice for Chiari malformation diagnostics. To improve these diagnostic practices, a better understanding of PC MRI based measurement agreement, repeatability, and reproducibility of CSF dynamics is needed.
Methods: An anatomically realistic in vitro subject specific model of a Chiari malformation patient was scanned three times at five different scanning centers using 2D PC MRI and 4D Flow techniques to quantify intra-scanner repeatability, inter-scanner reproducibility, and agreement between imaging modalities.