Prostate brachytherapy treatment using permanent implantation of low-energy (LE) low-dose rate (LDR) sources is successfully and widely applied in Europe. In addition, seeds are used in other tumour sites, such as ophthalmic tumours, implanted temporarily. The calibration issues for LE-LDR photon emitting sources are specific and different from other sources used in brachytherapy.
View Article and Find Full Text PDFPurpose: To evaluate in a multicenter setting the ability of centers to perform pre-implant permanent prostate brachytherapy planning, fulfilling dosimetric goals and constraints based on the Groupe de Curiethérapie-European Society for Radiotherapy and Oncology guidelines in the setting of implantation after prior prostate transurethral resection (TURP).
Material And Methods: A reference transrectal ultrasound image set of the prostate gland from a patient who had undergone TURP was used. Contouring of the prostate, clinical target volume and organs at risk was performed by the coordinating center.
Purpose: To compare the uncertainties in CT- and MRI-based seed reconstruction in postimplant evaluation after prostate seed brachytherapy in terms of interobserver variability and quantify the impact of seed detection variability on a selection of dosimetric parameters for three postplan techniques: (1) CT, (2) MRI-T1 weighted fused with MRI-T2 weighted, and (3) CT fused with MRI-T2 weighted.
Methods And Materials: Seven physicists reconstructed the seed positions on postimplant CT and MRI-T1 images of three patients. For each patient and imaging modality, the interobserver variability was calculated with respect to a reference seed set.
Introduction: In 2007 ESTRO proposed a revision and harmonisation of the core curricula for radiation oncologists, medical physicists and RTTs to encourage harmonised education programmes for the professional disciplines, to facilitate mobility between EU member states, to reflect the rapid development of the professions and to secure the best evidence-based education across Europe.
Material And Methods: Working parties for each core curriculum were established and included a broad representation with geographic spread and different experience with education from the ESTRO Educational Committee, local representatives appointed by the National Societies and support from ESTRO staff.
Results: The revised curricula have been presented for the ESTRO community and endorsement is ongoing.
The aim of this paper is to supplement the GEC/ESTRO/EAU recommendations for permanent seed implantations in prostate cancer to develop consistency in target and volume definition for permanent seed prostate brachytherapy. Recommendations on target and organ at risk (OAR) definitions and dosimetry parameters to be reported on post implant planning are given.
View Article and Find Full Text PDFBackground And Purpose: Brachytherapy is applied in 39 radiotherapy institutions in The Netherlands and Belgium. Each institution has its own quality control (QC) programme to ensure safe and accurate dose delivery to the patient. The main goal of this work is to gain insight into the current practice of QC of brachytherapy in The Netherlands and Belgium and to reduce possible variations in test frequencies and tolerances by formulating a set of minimum QC-requirements.
View Article and Find Full Text PDF