Joint acoustic emissions (JAEs) have been used as a non-invasive sensing modality of joint health for different conditions such as acute injuries, osteoarthritis (OA), and rheumatoid arthritis (RA). Recent hardware improvements for sensing JAEs have made at-home sensing to supplement clinical visits a possibility. To complement these advances, models must be improved for JAEs to function as generalizable predictors of joint health.
View Article and Find Full Text PDFImportance: Multimodal generative artificial intelligence (AI) methodologies have the potential to optimize emergency department care by producing draft radiology reports from input images.
Objective: To evaluate the accuracy and quality of AI-generated chest radiograph interpretations in the emergency department setting.
Design, Setting, And Participants: This was a retrospective diagnostic study of 500 randomly sampled emergency department encounters at a tertiary care institution including chest radiographs interpreted by both a teleradiology service and on-site attending radiologist from January 2022 to January 2023.
Objective: Tracking changes in hemodynamic congestion and the consequent proactive readjustment of treatment has shown efficacy in reducing hospitalizations for patients with heart failure (HF). However, the cost-prohibitive nature of these invasive sensing systems precludes their usage in the large patient population affected by HF. The objective of this research is to estimate the changes in pulmonary artery mean pressure (PAM) and pulmonary capillary wedge pressure (PCWP) following vasodilator infusion during right heart catheterization (RHC), using changes in simultaneously recorded wearable seismocardiogram (SCG) signals captured with a small wearable patch.
View Article and Find Full Text PDFBiosensors (Basel)
December 2021
In light of the recent Coronavirus disease (COVID-19) pandemic, peripheral oxygen saturation (SpO) has shown to be amongst the vital signs most indicative of deterioration in persons with COVID-19. To allow for the continuous monitoring of SpO, we attempted to demonstrate accurate SpO estimation using our custom chest-based wearable patch biosensor, capable of measuring electrocardiogram (ECG) and photoplethysmogram (PPG) signals with high fidelity. Through a breath-hold protocol, we collected physiological data with a wide dynamic range of SpO from 20 subjects.
View Article and Find Full Text PDFStorage of full-length endoscopic procedures is becoming increasingly popular. To facilitate large-scale machine learning (ML) focused on clinical outcomes, these videos must be merged with the patient-level data in the electronic health record (EHR). Our aim was to present a method of accurately linking patient-level EHR data with cloud stored colonoscopy videos.
View Article and Find Full Text PDFObjective: Optimizing peri-operative fluid management has been shown to improve patient outcomes and the use of stroke volume (SV) measurement has become an accepted tool to guide fluid therapy. The Transesophageal Doppler (TED) is a validated, minimally invasive device that allows clinical assessment of SV. Unfortunately, the use of the TED is restricted to the intra-operative setting in anesthetized patients and requires constant supervision and periodic adjustment for accurate signal quality.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2020
Advances in cancer therapeutics have dramatically improved the survival rate and quality of life in patients affected by various cancers, but have been accompanied by treatment-related cardiotoxicity, e.g. left ventricular (LV) dysfunction and/or overt heart failure (HF).
View Article and Find Full Text PDFIEEE J Biomed Health Inform
June 2021
Objective: We developed a wearable watch-based device to provide noninvasive, cuff-less blood pressure (BP) estimation in an at-home setting.
Methods: The watch measures single-lead electrocardiogram (ECG), tri-axial seismocardiogram (SCG), and multi-wavelength photoplethysmogram (PPG) signals to compute the pulse transit time (PTT), allowing for BP estimation. We sent our custom watch device and an oscillometric BP cuff home with 21 healthy subjects, and captured the natural variability in BP over the course of a 24-hour period.
Background: To estimate oxygen uptake (VO) from cardiopulmonary exercise testing (CPX) using simultaneously recorded seismocardiogram (SCG) and electrocardiogram (ECG) signals captured with a small wearable patch. CPX is an important risk stratification tool for patients with heart failure (HF) owing to the prognostic value of the features derived from the gas exchange variables such as VO. However, CPX requires specialized equipment, as well as trained professionals to conduct the study.
View Article and Find Full Text PDFCardiac MRI (CMR) techniques offer non-invasive visualizations of cardiac morphology and function. However, imaging can be time-consuming and complex. Seismocardiography (SCG) measures physical vibrations transmitted through the chest from the beating heart and pulsatile blood flow.
View Article and Find Full Text PDFBackground: Remote monitoring of patients with heart failure (HF) using wearable devices can allow patient-specific adjustments to treatments and thereby potentially reduce hospitalizations. We aimed to assess HF state using wearable measurements of electrical and mechanical aspects of cardiac function in the context of exercise.
Methods And Results: Patients with compensated (outpatient) and decompensated (hospitalized) HF were fitted with a wearable ECG and seismocardiogram sensing patch.
Biomed Instrum Technol
January 2017
A battery-operated active cooling/heating device was developed to maintain thermoregulation of trauma victims in austere environments while awaiting evacuation to a hospital for further treatment. The use of a thermal manikin was adopted for this study in order to simulate load testing and evaluate the performance of this novel portable active cooling/heating device for both continuous (external power source) and battery power. The performance of the portable body temperature conditioner (PBTC) was evaluated through cooling/heating fraction tests to analyze the heat transfer between a thermal manikin and circulating water blanket to show consistent performance while operating under battery power.
View Article and Find Full Text PDFGoal: Our objective is to provide a framework for extracting signals of interest from the wearable seismocardiogram (SCG) measured during walking at normal (subject's preferred pace) and moderately fast (1.34-1.45 m/s) speeds.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
April 2016
We present a low power multi-modal patch designed for measuring activity, altitude (based on high-resolution barometric pressure), a single-lead electrocardiogram, and a tri-axial seismocardiogram (SCG). Enabled by a novel embedded systems design methodology, this patch offers a powerful means of monitoring the physiology for both patients with chronic cardiovascular diseases, and the general population interested in personal health and fitness measures. Specifically, to the best of our knowledge, this patch represents the first demonstration of combined activity, environmental context, and hemodynamics monitoring, all on the same hardware, capable of operating for longer than 48 hours at a time with continuous recording.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2016
Heart failure (HF) is an escalating public health problem, with few effective methods for home monitoring. In HF management, the important clinical factors to monitor include symptoms, fluid status, cardiac output, and blood pressure--based on these factors, inotrope and diuretic dosages are adjusted day-by-day to control the disorder and improve the patient's status towards a successful discharge. Previously, the ballistocardiogram (BCG) measured on a weighing scale has been shown to be capable of detecting changes in cardiac output and contractility for healthy subjects.
View Article and Find Full Text PDFBackground: The purpose of this study was to investigate the utility and limitations of various imaging modalities in the noninvasive assessment of a novel compact hemodialyzer under development for renal replacement therapy, with specific aim towards monitoring its functional performance.
Methods: The prototype is a 4×3×6 cm aluminum cartridge housing "blood" and "dialysate" flow paths arranged in parallel. A sheet of semipermeable silicon nanopore membranes forms the blood-dialysate interface, allowing passage of small molecules.
Biologically inert elastomers such as silicone are favorable materials for medical device fabrication, but forming and curing these elastomers using traditional liquid injection molding processes can be an expensive process due to tooling and equipment costs. As a result, it has traditionally been impractical to use liquid injection molding for low-cost, rapid prototyping applications. We have devised a method for rapid and low-cost production of liquid elastomer injection molded devices that utilizes fused deposition modeling 3D printers for mold design and a modified desiccator as an injection system.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2015
Preterm birth is the leading cause of worldwide neonatal mortality. It follows a pathologically accelerated form of the normal processes that govern cervical softening and dilation. Softening and dilation occur due to changes in cervical collagen crosslinking, which can be measured non-invasively by changes in tissue fluorescence and impedance.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
December 2013
Preterm birth causes 1 million infant deaths worldwide every year, making it the leading cause of infant mortality. Existing diagnostic tests such as transvaginal ultrasound or fetal fibronectin either cannot determine if preterm birth will occur in the future or can only predict the occurrence once cervical shortening has begun, at which point it is too late to reverse the accelerated parturition process. Using iterative and rapid prototyping techniques, we have developed an intravaginal proof-of-concept device that measures both cervical bioimpedance and cervical fluorescence to characterize microstructural changes in a pregnant woman's cervix in hopes of detecting preterm birth before macroscopic changes manifest in the tissue.
View Article and Find Full Text PDFIEEE Trans Inf Technol Biomed
November 2012
Congenital pulmonary hypoplasia is a devastating condition affecting fetal and newborn pulmonary physiology, resulting in great morbidity and mortality. The fetal lung develops in a fluid-filled environment. In this work, we describe a novel, implantable pressure sensing and recording device which we use to study the pressures present in the fetal pulmonary tree throughout gestation.
View Article and Find Full Text PDF