Since ancient times, poisoning, even serious poisoning, has been known to occur during nature walks. Intentional or unintentional ingestion of toxins of animal origin is one of the possible causes of poisoning. Bufadienolide poisoning is a critical case.
View Article and Find Full Text PDFUnlabelled: Microsystems represent an alternative but proficient approach of analysis outside the laboratory, and their use could help in reducing the impact of pre-analytical errors, in particular in challenging newborn samples. The study purpose is to compare the Horiba Microsemi CRP LC-767G system for rapid 3-part complete blood count (CBC) and C-reactive protein (CRP) determination with the laboratory reference systems (respectively Sysmex XN-9100™ and Roche Cobas® c702) in samples of adult patients and newborns hospitalized in the neonatal intensive care unit (NICU) samples. The comparison between the analyzers was performed through Passing-Bablok regression analysis and Bland-Altman plot.
View Article and Find Full Text PDFBackground: Chemotherapy drugs are widely used to treat cancer, but their active compounds represent a danger for workers who could be exposed to them. However, they aren't yet included in directive CE No. 1272/2008 and the European Biosafety Network has only recommended a limit value of 100 pg/cm for surface contamination.
View Article and Find Full Text PDFBufo parotid glands and eggs contain cardiac glycosides also known as bufadienolides. This class of molecules can cause digoxin-like cardiac toxicity, as they can block the sodium potassium-adenosine triphosphatase (Na/K-ATPase) pump. Poisoning with these toxins is rare but carries a high mortality risk.
View Article and Find Full Text PDFIntroduction: Fetal lower urinary tract obstruction (LUTO) can be mild or severe with oligohydramnios, renal dysplasia and pulmonary hypoplasia. Fetal urine biochemical markers correlate with fetal prognosis and, if favorable, surgical intervention is feasible.
Methods: We report a patient in her 18th gestational week whose fetus was diagnosed with LUTO and underwent fetal urine sampling for calcium, sodium, chloride, beta2-microglobulin and total protein of the routine LUTO panel, with the addition of creatinine, glucose, phosphate, urea, ammonia, albumin, and NGAL.
The solid-phase microextraction (SPME), invented by Pawliszyn in 1989, today has a renewed and growing use and interest in the scientific community with fourteen techniques currently available on the market. The miniaturization of traditional sample preparation devices fulfills the new request of an environmental friendly analytical chemistry. The recent upswing of these solid-phase microextraction technologies has brought new availability and range of robotic automation.
View Article and Find Full Text PDFBackground: Cyclophosphamide (CP) and ifosfamide (IP) contaminations have been detected in hospital environments. This study was conducted to determine if there was any contamination in the spaces (floors and door handles) between the hospital exit and the antineoplastic drugs (ADs) preparation and administration units. At the same time, the authors proposed a new automation of the analytical procedure to considerably decrease the time needed for sample preparation and analysis.
View Article and Find Full Text PDFThe measurement of the potassium concentration (K) in vitreous humor (VH) has been a well-known adjunct for the estimation of the post-mortem interval (PMI) since the early 1960s. For years, however, many authors have been using other biochemical markers in an attempt to improve predictions. In this paper we confirm the role of K in the determination of the PMI adopting a linear regression model and we investigate whether other biochemical markers could improve the model through a multiple regression analysis.
View Article and Find Full Text PDFBackground: The case concerns a 30-year-old woman in the 24th week of pregnancy presenting to the medical emergency room with fever and abdominal pain. Urine sediment microscopy revealed the presence of unknown needle-shaped crystals.
Methods: Crystals identification was performed by Fourier-Transform Infrared Spectroscopy coupled to Attenuated Total Reflectance (FTIR-ATR).
Objectives: Hydrogen peroxide (HP) accounts for 15% of the total global chemical revenue. According to the National Institute of Occupational Safety and Health, the HP concentration immediately dangerous to human life or health is 75 ppm. Operators exposed to HP should pay attention when choosing the monitoring technique that should be specific and sensitive enough to discriminate the exposure levels from background concentrations.
View Article and Find Full Text PDFThe determination of urinary S-phenylmercapturic acid (S-PMA) represents the most reliable biomarker to monitor the intake risk of airborne benzene. Recently, the European Chemical Agency deliberated new occupational exposure limits for benzene and recommended an S-PMA biological limit value of 2-μg/g creatinine. This limit is an order of magnitude lower than the previous one, and its determination constitutes a challenge in the analytical field.
View Article and Find Full Text PDFCarbonyl compounds (CCs) are products present both as vapors and as condensed species adsorbed on the carbonaceous particle matter dispersed in the air of urban areas, due to vehicular traffic and human activities. Chronic exposure to CCs is a potential health risk given the toxicity of these chemicals. The present study reports on the measurement of the concentrations of 14 CCs in air as vapors and 2.
View Article and Find Full Text PDFLong-term indoor-air limit for formaldehyde stipulated by the European Commission is 1 μg/m, while the World Health Organization has set a threshold of 100 μg/m that should not be exceeded for more than 30 min. To date, however, only a few analytical techniques have been developed that can be used to detect formaldehyde at these very restrictive limits. Thus, there is a need to develop for comprehensive methods for analyzing airborne formaldehyde and other carbonyl pollutants in the ambient environment.
View Article and Find Full Text PDFThe aim of this study is to validate an integrated air monitoring approach for assessing airborne formaldehyde (FA) in the workplace. An active sampling by silica gel impregnated with 2,4-dinitrophenylhydrazine, a passive solid phase microextraction technique using O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine as on-fiber derivatization reagent, an electrochemical direct-reading monitor, and an enzyme-based badge were evaluated and tested over a range of 0.020-5.
View Article and Find Full Text PDFBackground: Cytotoxic antineoplastic drugs (ADs), widely used in treating cancer, are considered hazardous in the workplace and thus require safe handling practices. An analytical protocol for environmental and biological AD monitoring in the healthcare environment has been developed, since Europe lacks clear guidelines and regulations for cytostatic preparation and handling.
Material And Methods: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was used for measuring contemporaneously 20 multi-class cytostatic compounds and urinary α-fluoro-β-alanine, whereas platinum was detected by inductively coupled plasma mass spectrometry (ICP-MS).
Cytotoxic antineoplastic drugs (ADs) pose occupational risk and therefore require safe handling practices. We created, optimised, and validated an innovative monitoring protocol for simultaneously assessing 21 ADs in the healthcare environment, and also proposed surface exposure levels (SELs) to facilitate the interpretation of monitoring results, as there are currently no occupational exposure limits for ADs. The environmental AD monitoring data were collected in nine Italian hospitals between 2008 and 2017 and include 74,565 measurements in 4,814 wipe samples.
View Article and Find Full Text PDFHigh-throughput screening of samples is the strategy of choice to detect occupational exposure biomarkers, yet it requires a user-friendly apparatus that gives relatively prompt results while ensuring high degrees of selectivity, precision, accuracy and automation, particularly in the preparation process. Miniaturization has attracted much attention in analytical chemistry and has driven solvent and sample savings as easier automation, the latter thanks to the introduction on the market of the three axis autosampler. In light of the above, this contribution describes a novel user-friendly solid-phase microextraction (SPME) off- and on-line platform coupled with gas chromatography and triple quadrupole-mass spectrometry to determine urinary metabolites of polycyclic aromatic hydrocarbons 1- and 2-hydroxy-naphthalene, 9-hydroxy-phenanthrene, 1-hydroxy-pyrene, 3- and 9-hydroxy-benzoantracene, and 3-hydroxy-benzo[a]pyrene.
View Article and Find Full Text PDFInt J Occup Med Environ Health
July 2018
Objectives: In order to assess short-term exposure to peracetic acid (PAA) in disinfection processes, the Authors compared 4 industrial hygiene monitoring methods to evaluate their proficiency in measuring airborne PAA concentrations.
Material And Methods: An active sampling by basic silica gel impregnated with methyl p-tolyl sulfoxide (MTSO), a passive solid phase micro-extraction technique using methyl p-tolyl sulfide (MTS) as on-fiber derivatization reagent, an electrochemical direct-reading PAA monitor, and a novel visual test strip PAA detector doped with 2,2'-azino-bis (3-ethylbenzothiazoline)-6-sulfonate were evaluated and tested over the range of 0.06-16 mg/m3, using dynamically generated PAA air concentrations.
Objectives: To evaluate the feasibility and safety of the MIRUS system (Pall International, Sarl, Fribourg, Switzerland) for sedation with sevoflurane for postsurgical ICU patients and to evaluate atmospheric pollution during sedation.
Design: Prospective interventional study.
Setting: Surgical ICU.
Hydrogen fluoride (HF) is a basic raw material for a wide variety of industrial products, with a worldwide production capacity of more than three million metric tonnes. A novel method for determining particulate fluoride and gaseous hydrogen fluoride in air is presented herewith. Air was sampled using miniaturised 13 mm Swinnex two-stage filter holders in a medium-flow pumping system and through the absorption of particulate fluoride and HF vapours on cellulose ester filters uncoated or impregnated with sodium carbonate.
View Article and Find Full Text PDFBackground: Nitrous oxide (N2 O 50% in oxygen) is commonly used for painful procedures in children. Potential negative health effects associated with chronic workplace exposure limit its use. Safe occupational N2 O exposure concentrations are below 25 ppm environmental concentration as a time-weighted average (TWA) and below 200 ppm as a short-time exposure level (STEL) of 15 min.
View Article and Find Full Text PDF