Publications by authors named "Aleksandar Radu"

We have developed a sensing system that utilizes a low-cost computer (Raspberry Pi) and its imaging camera as an optical sensing core for the continuous detection of NO in the air (PiSENS-A). The sensor is based on colour development as a consequence of the interaction of the gas with an absorbing solution. The PiSENS-A is thoroughly calibrated over the hourly mean which is used as one of the key metrics in evaluating air quality.

View Article and Find Full Text PDF

We report on the development of a simple and cost-effective potentiometric sensor array that is based on manual "drawing" on the polymeric support with the pencils composed of graphite and different types of zeolites. The sensor array demonstrates distinct sensitivity towards a variety of inorganic ions in aqueous media. This multisensor system has been successfully applied to quantitative analysis of 100 real-life surface waters sampled in Mahananda and Hooghly rivers in the West Bengal state (India).

View Article and Find Full Text PDF

In this paper, we demonstrate the suitability, sensitivity, and precision of low-cost and easy-to-use ion-selective electrodes (ISEs) for concurrent detection of NH and NO in soil and water by technical and non-technical end-users to enable efficient soil and water management exposed to chronic reactive nitrogen loading. We developed a simplified methodology for sample preparation followed by the demonstration of an analytical methodology resulting in improvements of sensitivity and precision of ISEs. Herein, we compared and contrasted ISEs with traditional laboratory-based technique such as Flow Injection Analysis (FIA) and portable colorimetric assay followed by comparisons of linear regression and Bayesian nonlinear calibration approaches applied on both direct potentiometry and standard addition modes of analysis in terms of in-field applications and improvement of sensitivity and precision.

View Article and Find Full Text PDF

Aluminium-selective ion optical sensor based on covalently attached lumogallion methacrylate was synthesized and investigated in this study. Lumogallion based derivatives were copolymerized with various methacrylate monomers via a simple one step free radical polymerization to produce a "self-plasticized" copolymer. We demonstrate that covalently attached lumogallion moieties provide adequate functionality to the optical film thus achieving a very simple, one component sensing membrane.

View Article and Find Full Text PDF

Although IUPAC has recommended a probabilistic approach to determining limit of detection (LOD) based on false-positive and false-negative rates for more than 20 years, the LOD definition for ion-selective electrodes (ISEs) long predates these recommendations and conflicts substantively with them. Although it is well known that the ISE LOD definition does not follow best practice, it continues to be used due to simplicity and a lack of available methods for estimating LOD for nonlinear sensors. Here, we use ISEs as a model system for estimation of LOD for nonlinear sensors that is consistent with broad IUPAC recommendations and justified using statistical theory.

View Article and Find Full Text PDF

A new software package, , is introduced for use within the popular open-source programming language R that allows Bayesian statistical data analysis techniques to be implemented in a straightforward manner. Incorporating all collected data simultaneously, this Bayesian approach naturally accommodates sensor arrays and provides improved limit of detection estimates, including providing appropriate uncertainty estimates. Utilising >1500 lines of code, provides a set of three core functions-loadISEdata, describeISE, and analyseISE- for analysing ion-selective electrode data using the Nikolskii-Eisenman equation.

View Article and Find Full Text PDF

Simple, robust, and low-cost nitrate- and ammonium-selective electrodes were made using substrate prepared from household materials. We explored phosphonium-based ILs and poly (methyl methacrylate)/poly(decyl methacrylate)(MMA-DMA) copolymer as matrix materials alternative to classical PVC-based membranes. IL-based membranes showed suitability only for nitrate-selective electrode exhibiting linear concentration range between 5.

View Article and Find Full Text PDF

Preparation of ion-selective electrodes (ISEs) often requires long and complicated conditioning protocols limiting their application as tools for in-field measurements. Herein, we eliminated the need for electrode conditioning by loading the membrane cocktail directly with primary ion solution. This proof of concept experiment was performed with iodide, silver, and sodium selective electrodes.

View Article and Find Full Text PDF

The applicability of ion exchange membranes is mainly defined by their permselectivity towards specific ions. For instance, the needed selectivity can be sought by modifying some of the components required for the preparation of such membranes. In this study, a new class of materials -trihexyl(tetradecyl)phosphonium based ionic liquids (ILs) were used to modify the properties of ion exchange membranes.

View Article and Find Full Text PDF

Novel solid-contact iodide-selective electrodes based on covalently attached 1,2,3 triazole ionic liquid (IL) were prepared and investigated in this study. Triazole-based IL moieties were synthesized using click chemistry and were further copolymerized with lauryl methacrylate via a simple one-step free radical polymerization to produce a "self-plasticized" copolymer. The mechanical properties of the copolymer are suitable for the fabrication of plasticizer-free ion-selective membrane electrodes.

View Article and Find Full Text PDF

Quantitative analysis of the carbonate species within clinical and environmental samples is highly critical to the advancement of accurate environmental monitoring, disease screening, and personalized medicine. Herein we report the first example of carbonate detection using ultrasensitive ion selective electrodes (ISEs). The low detection limit (LDL) of these electrodes was at least 4 orders of magnitude lower than the best currently existing carbonate sensors.

View Article and Find Full Text PDF

This work details the use of a 2-component optode membrane which is capable of generating three distinct colours in the presence of Cu(2+) and Co(2+) ions. It has been found that the ionic liquid (IL) trihexyltetradecylphosphonium dicyanamide [P(6,6,6,14)][DCA] can act as plasticizer, ligand and transducer dye when used in poly(vinyl chloride) (PVC) membranes, which significantly simplifies the optode membrane cocktail. Upon exposure to an aqueous Cu(2+) solution, a yellow colour is generated within the membrane, while exposure to an aqueous Co(2+) solution generates a blue colour.

View Article and Find Full Text PDF

A simple procedure for the development of a range of polymeric ion-selective electrodes (ISEs) with low detection limits is presented. The electrodes were prepared by using a plasticizer-free methyl methacrylate-decyl methacrylate copolymer as membrane matrix and poly(3-octylthiophene) as intermediate layer deposited by solvent casting on gold sputtered copper electrodes as a solid inner contact. Five different electrodes were developed for Ag+, Pb2+, Ca2+, K+, and I-, with detection limits mostly in the nanomolar range.

View Article and Find Full Text PDF

Ion-selective electrodes and optodes based on the anticrown ionophore mercuracarborand-3 (MC-3) exhibit excellent selectivity to halide ions but suffer from a low upper detection limit because of very strong complexation in the sensing phase. In this work, we have successfully improved the upper detection limit and widened the working range of chloride selective electrode based on MC-3 by introducing 1-decanethiol into the membrane cocktail. With an assumed 1:2 stoichiometry between chloride and MC-3 the apparent complex formation constant was reduced from log beta = 13.

View Article and Find Full Text PDF

An optical microsensor array is described for the rapid analysis of silver ions at low parts per trillion levels. Because the ionophore o-xylylenebis(N,N-diisobutyldithiocarbamate) (Cu-I) was reevaluated and shown to exhibit excellent selectivity for silver ions, ion-selective electrode (ISE) membranes were optimized and found to exhibit the lowest reported detection limit so far (3 x 10(-10) M). A corresponding Ag+-selective fluorescent optical microsensor array for the rapid sensing of trace level Ag+ was then developed.

View Article and Find Full Text PDF

A numerical solution for the prediction of the time-dependent potential response of a polymeric-based ion-selective electrode (ISE) is presented. The model addresses short- and middle-term potential drifts that are dependent on changes in concentration gradients in the aqueous sample and organic membrane phase. This work has important implications for the understanding of the real-time response behavior of potentiometric sensors with low detection limits and with nonclassical super-Nernstian response slopes.

View Article and Find Full Text PDF

The extent of optimization of the lower detection limit of ion-selective electrodes (ISEs) can be assessed with an elegant new method. At the detection limit (i.e.

View Article and Find Full Text PDF

The lower detection limit and the selectivity behavior of anion-selective electrodes (ISEs) are improved by using optimized inner solutions and membrane compositions. With a membrane based on the recently described ionophore [9]mercuracarborand-3, a detection limit of 2 x 10(-9) M has been achieved for iodide. Nevertheless, the improvements are less pronounced than in the case of cation ISEs.

View Article and Find Full Text PDF

A derivative of a known Ca2+-selective ionophore, ETH 129, was synthesized to contain a polymerizable acrylic moiety (AU-1) and covalently grafted into a methyl methacrylate-co-decyl methacrylate polymer matrix. The polymer containing AU-1 was prepared via a simple one-step homogeneous polymerization method. It exhibited mechanical properties suitable for the fabrication of plasticizer-free ion-selective membrane electrodes and bulk optode films by solvent-casting and spin-coating techniques, respectively.

View Article and Find Full Text PDF

Submicromolar to picomolar lower detection limits have recently been obtained with various polymer membrane ion-selective electrodes by minimizing biases due to ion fluxes through the membrane. For the best performance, the compositions of the membrane and inner solution should be optimized for each application. Given the number of parameters to be adjusted, it has been difficult to find the best parameters for a target sample.

View Article and Find Full Text PDF