Background: External quality assessment schemes (EQAS) can provide important information regarding accuracy and comparability of different measurement methods if the sample matrices are composed of commutable material. The aim of this study was to assess the commutability of different matrices for the material used in an EQAS for amitriptyline and nortriptyline.
Methods: Proficiency testing material (PTM) and patient samples containing amitriptyline and nortriptyline were prepared, collected, pooled, and distributed to participating laboratories for analysis.
Background: Results from external quality assessment schemes (EQASs) can provide information about accuracy and comparability of different measurement methods, provided that the material used in these schemes behave identical to patient samples among the different methods, a characteristic also known as commutability. The aim of this study was to assess the commutability of different matrices for the material used in an EQAS for tobramycin.
Methods: Proficiency testing material (PTM) and patient samples containing tobramycin were prepared, collected, pooled, and distributed to participating laboratories for analysis.
Background: Medical laboratories are required to participate in interlaboratory comparisons of the analyses they perform. The materials used in these comparisons need to be of sufficient quality so that the comparison provides a picture of the performances. One of the main characteristics of the testing material is commutability, which is the ability of a material to yield the same numerical relationships between results of measurements as those relationships obtained when the same procedures are applied to patient samples.
View Article and Find Full Text PDFBackground: An increase in urine calcium compared to the consensus value was observed in some urine samples of the Dutch External Quality Assessment Scheme (EQAS). It appeared that the increase was due to the addition of oxalate by the EQAS organizers and preanalytical acidification of the samples by some of the participants. Because of this observation, the effect of urine acidification on urine calcium level in EQAS and patient samples with added oxalate was investigated.
View Article and Find Full Text PDFUnlabelled: In the framework of a Dutch project named "Calibration 2000" harmonization of antithrombin activity assays was studied. The commutability of potential calibrators for antithrombin was assessed by means of a twin-study design, which is a multicentre, split-patient sample, between-field-methods protocol. The twin-study consisted of simultaneous analysis of fresh-frozen patient plasmas and three potential calibrators for antithrombin by 30 Dutch laboratories forming 15 couples.
View Article and Find Full Text PDFIn a Dutch project for harmonisation of factor VIII coagulant activity (FVIII:C) assays, the commutability of potential calibrators for FVIII:C was assessed by means of a 'twin-study design', which is in essence a multi-centre, split-patient sample, between-field-methods protocol. Commutability was defined as the degree to which a material yielded the same numerical relationships between results of measurements by a given set of measurement procedures as those between the expectations of the relationships for the same procedures applied to those types of material for which the procedures were intended. The study consisted of the simultaneous analysis of fresh frozen patient plasmas and three potential calibrators for FVIII:C by 16 Dutch laboratories forming eight couples.
View Article and Find Full Text PDF