Aims: The randomized, double-blind, placebo-controlled HOPE-HF trial assessed the benefit of atrio-ventricular (AV) delay optimization delivered using His bundle pacing. It recruited patients with left ventricular ejection fraction ≤40%, PR interval ≥200 ms, and baseline QRS ≤140 ms or right bundle branch block. Overall, there was no significant increase in peak oxygen uptake (VOmax) but there was significant improvement in heart failure specific quality of life.
View Article and Find Full Text PDFThe role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs.
View Article and Find Full Text PDFBackground: No periprocedural metric has demonstrated improved cardiac resynchronization therapy (CRT) outcomes in a multicenter setting.
Objective: We sought to determine if left ventricular (LV) lead placement targeted to the coronary sinus (CS) branch generating the best acute hemodynamic response (AHR) results in improved outcomes at 6 months.
Methods: In this multicenter randomized controlled trial, patients were randomized to guided CRT or conventional CRT.
Purpose: X-ray coronary angiography (XCA) is the current gold standard for the assessment of lumen encroaching coronary stenosis but XCA does not allow for early detection of rupture-prone vulnerable plaques, which are thought to be the precursor lesions of most acute myocardial infarctions (AMI) and sudden death. The aim of this study was to investigate the potential of delayed contrast-enhanced magnetic resonance coronary vessel wall imaging (CE-MRCVI) for the detection of culprit lesions in the coronary arteries.
Methods: 16 patients (13 male, age 61.
Myocardial stiffness is a valuable clinical biomarker for the monitoring and stratification of heart failure (HF). Cardiac finite element models provide a biomechanical framework for the assessment of stiffness through the determination of the myocardial constitutive model parameters. The reported parameter intercorrelations in popular constitutive relations, however, obstruct the unique estimation of material parameters and limit the reliable translation of this stiffness metric to clinical practice.
View Article and Find Full Text PDFBackground: The high risk of ventricular arrhythmias in patients with heart failure remains despite the benefit of cardiac resynchronization therapy (CRT). An electromechanical interaction between regional myocardial strain patterns and the electrophysiological substrate is thought to be important.
Objective: We investigated the in vivo relation between left ventricular activation recovery interval (ARI), as a surrogate measure of action potential duration (APD), and local myocardial strain patterns in responders and nonresponders to CRT.
Introduction: Recent efforts to increase CRT response by multiSPOT pacing (MSP) from multiple bipols on the same left ventricular lead are still inconclusive.
Aim: The Left Ventricular (LV) MultiSPOTpacing for CRT (iSPOT) study compared the acute hemodynamic response of MSP pacing by using 3 electrodes on a quadripolar lead compared with conventional biventricular pacing (BiV).
Methods: Patients with left bundle branch block (LBBB) underwent an acute hemodynamic study to determine the %change in LV+dP/dtmax from baseline atrial pacing compared to the following configurations: BiV pacing with the LV lead in a one of lateral veins, while pacing from the distal, mid, or proximal electrode and all 3 electrodes together (i.
Introduction: Many heart failure patients with dyssynchrony do not reverse remodel (RR) in response to cardiac resynchronization therapy (CRT). The presence of focal and diffuse interstitial myocardial fibrosis may explain this high nonresponse rate. T1 mapping is a new cardiac magnetic resonance imaging (CMR) technique that overcomes the limitations of conventional contrast CMR and provides reliable quantitative assessment of diffuse myocardial fibrosis.
View Article and Find Full Text PDFObjectives: This study sought to determine the effect of contact force (CF) on atrial lesion size, quality, and transmurality by using a chronic porcine model of radiofrequency ablation.
Background: CF is a major determinant of ventricular lesion formation, but uncertainty exists regarding the most appropriate CF parameters to safely achieve permanent, transmural lesions in the atria.
Methods: Intercaval linear ablation (30 W, 42°C, 17 ml/min irrigation) was performed in 8 Göttingen minipigs by using a force-sensing catheter with CF >20 g (high force) or <10 g (low force) at alternate ends of the line, separated by an intentional gap.
Background: Multisite pacing (MSP) of the left ventricle is proposed as an alternative to conventional single-site LV pacing in cardiac resynchronization therapy (CRT). Reports on the benefits of MSP have been conflicting. A paradigm whereby not all patients derive benefit from MSP is emerging.
View Article and Find Full Text PDFAims: To prospectively compare cardiac magnetic resonance late gadolinium enhancement (LGE) findings created by standard vs. robotically assisted catheter ablation lesions and correlate these with clinical outcomes.
Methods And Results: Forty paroxysmal atrial fibrillation patients (mean age 54 ± 13.
Background: Studies have reported an inverse relationship between late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) signal intensity and left atrial (LA) endocardial voltage after LA ablation. However, there is controversy regarding the reproducibility of atrial LGE CMR and its ability to identify gaps in ablation lesions. Using systematic and objective techniques, this study examines the correlation between atrial CMR and endocardial voltage.
View Article and Find Full Text PDFModel personalization is a key aspect for biophysical models to impact clinical practice, and cardiac contractility personalization from medical images is a major step in this direction. Existing gradient-based optimization approaches show promising results of identifying the maximum contractility from images, but the contraction and relaxation rates are not accounted for. A main reason is the limited choices of objective functions when their gradients are required.
View Article and Find Full Text PDFBackground: Diffuse myocardial fibrosis may provide a substrate for the initiation and maintenance of ventricular arrhythmia. T1 mapping overcomes the limitations of the conventional delayed contrast-enhanced cardiac magnetic resonance (CE-CMR) imaging technique by allowing quantification of diffuse fibrosis.
Objective: The purpose of this study was to assess whether myocardial tissue characterization using T1 mapping would predict ventricular arrhythmia in ischemic and non-ischemic cardiomyopathies.
Purpose: Image-guided cardiac interventions involve the use of fluoroscopic images to guide the insertion and movement of interventional devices. Cardiorespiratory gating can be useful for 3D reconstruction from multiple x-ray views and for reducing misalignments between 3D anatomical models overlaid onto fluoroscopy.
Methods: The authors propose a novel and potentially clinically useful retrospective cardiorespiratory gating technique.
Background And Aims Of Study: Septal flash (SF) describes early inward motion of the ventricular septum in patients with left bundle branch block (LBBB), and correction corresponds to increased response to cardiac resynchronization therapy (CRT). SF has traditionally been assessed by echocardiography. We sought to determine if cardiac magnetic resonance (CMR) imaging could identify SF and if the additional assessment of scar would improve the ability of CMR to predict CRT response.
View Article and Find Full Text PDFIntroduction: A quadripolar left ventricular (LV) pacing can deliver multipoint pacing (MPP). It is unknown if this confers improved cardiac function compared to conventional cardiac resynchronization therapy (CRT).
Methods And Results: We aimed to characterize changes in acute cardiac contractility and hemodynamics with multisite left ventricular "multipoint" pacing (MPP) in a prospective multicenter study in patients implanted with a CRT-defibrillator incorporating a quadripolar LV lead.
Surface flattening in medical imaging has seen widespread use in neurology and more recently in cardiology to describe the left ventricle using the bull's-eye plot. The method is particularly useful to standardize the display of functional information derived from medical imaging and catheter-based measurements. We hypothesized that a similar approach could be possible for the more complex shape of the left atrium (LA) and that the surface flattening could be useful for the management of patients with atrial fibrillation (AF).
View Article and Find Full Text PDF