Publications by authors named "Alberto Lopez-Miguel"

Objectives: To evaluate the reliability and agreement of tear meniscus height (TMH) measurements performed with a corneal analyzer and optical coherence tomography (OCT) technology in contact lens (CL) wearers and its correlation with contact lens discomfort symptoms.

Methods: Asymptomatic and symptomatic CL wearers classified through the Contact Lens Dry Eye Questionnaire-8 were evaluated with the Corneal Analyzer (Topcon CA-800) and OCT technology (Topcon 3D OCT-2000). The repeatability and intraclass correlation coefficient (ICC) were calculated.

View Article and Find Full Text PDF

Purpose: To analyze changes in tear levels of inflammatory mediators in symptomatic contact lens (CL) wearers after refitting with daily disposable CLs and to identify potential biomarkers of success in CL discomfort (CLD) management.

Methods: Symptomatic CL wearers (CLDEQ-8 ≥ 12) were refitted (V1) with daily disposable CLs (Delefilcon A). After one month (V2), participants were classified into the post-fitting non-symptomatic (CLDEQ <12) and symptomatic (CLDEQ ≥12) groups.

View Article and Find Full Text PDF

Introduction: To evaluate the short-term efficacy of cyclosporine A (CsA)-0.1% cationic emulsion (CE) in patients with dry eye disease (DED) and mitigation of the inflammatory flares triggered by desiccating stress environments.

Methods: A single-center non-randomized clinical trial was performed at a tertiary care setting.

View Article and Find Full Text PDF

Introduction: Characterizing lens thickness (LT) in patients with cataracts is important for better understanding the lens aging process and for designing new intraocular lens power formulas. This study aimed to analyze the influence of common senile cataract formation on the LT, anterior (ACS) and posterior (PCS) cortex space, and nuclear thickness (NT), controlling for sex, age, and axial length.

Methods: A cross-sectional study was performed.

View Article and Find Full Text PDF

Objective: The purpose of this study was to assess the visual performance and monochromatic higher-order aberrations (HOAs) obtained while wearing a MiSight dual-focus (DF) contact lenses (CL) in comparison with a single-vision contact lens (SVCL).

Methods: A randomized, double-masked, cross-over study was performed. Participants were fitted with a DFCL and a SVCL composed of the same material (omafilcon A) and parameters.

View Article and Find Full Text PDF

Purpose: This study aimed to assess the subjective and objective differences among the steps of the contact lens discomfort (CLD) progression classification established by the Tear Film & Ocular Surface Society (TFOS) using questionnaires and clinical signs, and to propose a simplified classification.

Methods: Contact lens (CL) wearers were evaluated in a single visit. The Contact Lens Dry Eye Questionnaire (CLDEQ)-8, the Contact Lens Discomfort Index, and Visual Analog Scales for discomfort and dryness were administered.

View Article and Find Full Text PDF

Purpose: To assess the reliability and agreement of non-invasive break-up time (NIBUT) in symptomatic and asymptomatic contact lens (CL) wearers using automatic objective and conventional subjective techniques.

Methods: In this prospective cross-sectional study, soft CL wearers, classified into symptomatic and asymptomatic based on the Contact Lens Dry Eye Questionnaire-8, underwent NIBUT assessment with the CL in situ. The CA-800 Corneal Analyzer and the EasyTear® VIEW+ Tearscope were used for objective and subjective evaluation, respectively.

View Article and Find Full Text PDF

Introduction: The aim of this work is to evaluate the effect of mesenchymal stem cell transplantation (MSCT) and cultivated limbal epithelial transplantation (CLET) therapies on the limbus of patients suffering from limbal stem cell deficiency (LSCD).

Methods: A sub-analysis of a phase I-II randomized, controlled, and double-masked clinical trial was performed to assess the changes in the anatomical structures of the limbus. In vivo confocal microscopy (IVCM) analysis was carried out in LSCD eyes before and 12 months after allogeneic MSCT or CLET.

View Article and Find Full Text PDF

Purpose: To evaluate the effect of EVO+ Visian Implantable Collamer Lens (ICL) implantation on the iridocorneal angle pigmentation and structures.

Methods: Myopic refractive surgery candidates who underwent posterior chamber EVO+ ICL implantation were evaluated preoperatively and 3 and 6 months postoperatively. High-resolution images of the iridocorneal angle (nasal, superior, temporal and inferior quadrants) were acquired during gonioscopy.

View Article and Find Full Text PDF

Purpose: To assess the relationship between anterior chamber depth (ACD) and lens thickness (LT), as well as its three main components (anterior and posterior cortex and nucleus thickness), in cataractous and non-cataractous eyes, depending on the axial length (AxL).

Methods: Anterior and posterior cortex and nucleus thickness of the crystalline lens, ACD, and AxL were measured using optical low-coherence reflectometry in cataractous and non-cataractous eyes. They were also classified into hyperopia, emmetropia, myopia, and high myopia, depending on AxL; thus, eight subgroups were created.

View Article and Find Full Text PDF

Introduction: Intraocular lens implantation in phakic eyes for the correction of refractive error is currently a widespread procedure. The EVO and EVO+ Visian Implantable Collamer Lenses (ICL) are two of the most prevalent lenses implanted. They incorporate a central orifice to avoid the need for iridotomy.

View Article and Find Full Text PDF

Purpose: To assess the repeatability and agreement of Cartesian coordinates and the length of apparent chord mu and pupil diameter measurements during static (Galilei G4) and dynamic (Topolyzer Vario) evaluations.

Setting: IOBA-Eye Institute, Valladolid, Spain.

Design: Case series.

View Article and Find Full Text PDF

Purpose: To assess whether the postoperative outcomes of the implantation of an EVO + implantable collamer lens (ICL) in one eye can be used as a predictor of the vault of the fellow eye, and to evaluate the vault changes of the implantation in both eyes during the postoperative period.

Methods: A prospective study including 40 eyes of 20 patients with a bilateral EVO + ICL implantation was performed. Subjects were evaluated before the surgery and 1 day, 1 week and 1, 3 and 6 months postoperatively.

View Article and Find Full Text PDF

To assess the prophylactic effect of LipiFlow treatment in Meibomian gland dysfunction (MGD) patients exposed to an adverse environmental humidity. MGD patients were exposed to normal (23 °C; 50% relative humidity; 30 min) and adverse (23 °C; 10% relative humidity; 2 h) controlled environments consecutively during baseline and follow-up visits (3, 6, and 12 months) after a single LipiFlow treatment. Ocular Surface Disease Index (OSDI), lipid layer thickness (LLT), fluorescein tear break-up time (TBUT), corneal and conjunctival staining, change in dry eye symptoms questionnaire (CDES-Q), and Meibomian gland yielding liquid secretion (MGYLS), were assessed.

View Article and Find Full Text PDF

Background/objectives: To determine the influence of decentration and tilt of a pseudophakic aspheric intraocular lens (IOL) on visual acuity (VA) and higher-order aberrations (HOAs), and to analyze the agreement between pupil center/axis and iridocorneal angles center/axis when assessing IOL decentration and tilt.

Subjects/methods: A prospective interventional case series study including thirty-three patients undergoing Tecnis ZCB00 (Abbott Medical Optics) implantation. IOL decentration and tilt with respect to two reference systems (pupil and iridocorneal angles centers/axes), in cartesian (X,Y) and polar (radius/tilt, polar angle/azimuth) coordinates, were assessed with optical coherence tomography.

View Article and Find Full Text PDF

Purpose: To describe the clinical characteristics of patients suffering from chronic dry eye (DE) and pain after refractive surgery (RS).

Methods: Cross-sectional, observational, single-visit study. DE-, pain- and psychological-related symptoms were evaluated with specific questionnaires.

View Article and Find Full Text PDF

Purpose: To investigate the effect of time of day on tear evaporation rate (TER) and tear break-up time, and its possible relationship with the concentration of inflammatory tear molecules (cytokines) in healthy subjects.

Methods: Participants with healthy ocular surfaces attended 3 visits, including the screening visit (V0), the 2nd visit (V1) and the 3rd visit (V2). There were 7-day intervals between visits.

View Article and Find Full Text PDF

Purpose: To determine the longitudinal variation in the KS-aquaPORT central hole location of the phakic EVO+I Implantable Collamer Lens (ICL) (STAAR Surgical) and analyze its influence on visual performance, quality of vision (QoV), and quality of life (QoL).

Methods: A prospective study was performed including 36 patients who had EVO+ ICL implantation. The KS-aquaPORT central hole location (Cartesian and polar coordinates) was determined with respect to the pupil center and visual axis.

View Article and Find Full Text PDF

Introduction: There is a lack of evidence about the exact deterioration of visual function associated with the age-related natural changes in the lens, particularly in intermediate (stage-2) dysfunctional lens syndrome (DLS). Standard photopic visual acuity and contrast sensitivity tests may not show the visual worsening in daily life activities, such as oncoming vehicle headlights at night. The purpose of this study was to analyze visual function under different conditions and glare sources in stage-2 DLS.

View Article and Find Full Text PDF

Objectives: To evaluate the usefulness of a global rate of change scale (GRCS) to detect variations in contact lens discomfort (CLD).

Methods: Symptomatic contact lens (CL) wearers were recruited according to the 'Contact Lens Dry Eye Questionnaire-8' (CLDEQ-8). At the baseline visit, subjects scored their comfort following insertion of their habitual CL using a 0-100 visual analogue scale (VAS).

View Article and Find Full Text PDF

Background: Prevalence of high myopia is continuously increasing, thus, patients affected with staphyloma are abundant worldwide. Assessment of the quality of vision in these patients is mandatory for a proper clinical counselling, specially when undergoing surgical procedures that require intraocular lenses implantation. Thus, the purpose of the study was to assess monochromatic higher order aberrations (HOAs) in highly myopic eyes with staphyloma with or without a dome-shaped macula.

View Article and Find Full Text PDF

Clinical Relevance: Questionnaires can provide unique information regarding the status of a condition from the perspective of the patient. Contact lens (CL) discomfort (CLD) is a condition subjectively reported by CL users; thus, updated and reliable questionnaires are needed.

Background: The objective of this study was to design a new questionnaire for identifying CLD, based on the currently established CLD definition considered in the Tear Film and Ocular Surface CLD Workshop.

View Article and Find Full Text PDF

Purpose: To assess the effect of EVO+ (V5) Visian implantable collamer lens implantation on mesopic visual performance, quality of vision (QoV), and quality of life (QoL).

Design: Prospective interventional case series.

Methods: Thirty-six eyes of 36 participants who underwent EVO+ implantation for myopia were evaluated preoperatively and at postoperative visits at 1 week and 1, 3, and 6 months.

View Article and Find Full Text PDF

Purpose: To study the effect of daily disposable contact lens (DDCL) refitting in monthly contact lens (CL) wearers suffering from contact lens discomfort (CLD), and to assess if there is a placebo effect associated with this CLD intervention.

Methods: Symptomatic CL wearers, according to the Contact Lens Dry Eye Questionnaire 8 (CLDEQ-8 ≥ 12 points), were divided into two groups. The study group was provided with DDCLs (delefilcon A) and the control group with a masked pair of their habitual monthly CLs (placebo effect) and were assessed after one month.

View Article and Find Full Text PDF

The most prevalent type of meibomian gland dysfunction (MGD), which is obstructive, is the main cause of evaporative dry eye and is characterized by changes in the meibum composition and duct obstruction. Eyelid hygiene has usually been the most common clinical approach. However, alternative therapies for MGD are emerging on the market.

View Article and Find Full Text PDF