Publications by authors named "Albertini F"

. Image-guided and adaptive proton therapy rely on daily CBCT or CT imaging, which increases radiation dose and radiation-induced cancer risk. Online adaptation however also reduces setup uncertainty, and the additional risk might be compensated by reducing the setup robustness margin.

View Article and Find Full Text PDF

This study presents the first clinical implementation of an efficient online daily adaptive proton therapy workflow (DAPT).The DAPT workflow includes awhere aand aare optimized on the planning computed tomography (CT). In the, theis re-optimized on daily images from an in-room CT.

View Article and Find Full Text PDF

Purpose: Proton beam therapy (PBT) plays an important role in the management of primary spine tumors. The purpose of this consensus statement was to summarize safe and optimal delivery of PBT for spinal tumors.

Methods And Materials: The Particle Therapy Cooperative Group Skull Base/Central nervous system/Sarcoma Subcommittee consisting of radiation oncologists and medical physicists with specific expertise in spinal irradiation developed expert recommendations discussing treatment planning considerations and current approaches in the treatment of primary spinal tumors.

View Article and Find Full Text PDF

To experimentally validate two online adaptive proton therapy (APT) workflows using Gafchromic EBT3 films and optically stimulated luminescent dosimeters (OSLDs) in an anthropomorphic head-and-neck phantom.A three-field proton plan was optimized on the planning CT of the head-and-neck phantom with 2.0 Gy(RBE) per fraction prescribed to the clinical target volume.

View Article and Find Full Text PDF

Online adaptive radiation therapy requires fast and automated contouring of daily scans for treatment plan re-optimization. However, automated contouring is imperfect and introduces contour uncertainties. This work aims at developing and comparing robust optimization strategies accounting for such uncertainties.

View Article and Find Full Text PDF

. Predicting potential deformations of patients can improve radiotherapy treatment planning. Here, we introduce new deep-learning models that predict likely anatomical changes during radiotherapy for head and neck cancer patients.

View Article and Find Full Text PDF

Purpose: Head and neck cancer (HNC) patients in radiotherapy require adaptive treatment plans due to anatomical changes. Deformable image registration (DIR) is used in adaptive radiotherapy, e.g.

View Article and Find Full Text PDF

Purpose: To demonstrate the suitability of optically stimulated luminescence detectors (OSLDs) for accurate simultaneous measurement of the absolute point dose and dose-weighted linear energy transfer (LET) in an anthropomorphic phantom for experimental validation of daily adaptive proton therapy.

Methods: A clinically realistic intensity-modulated proton therapy (IMPT) treatment plan was created based on a CT of an anthropomorphic head-and-neck phantom made of tissue-equivalent material. The IMPT plan was optimized with three fields to deliver a uniform dose to the target volume covering the OSLDs.

View Article and Find Full Text PDF

Excessive iron levels are believed to contribute to the development of neurodegenerative disorders by promoting oxidative stress and harmful protein clustering. Novel chelation treatments that can effectively remove excess iron while minimizing negative effects on the nervous system are being explored. This study focuses on the creation and evaluation of innovative nanobubble (NB) formulations, shelled with various polymers such as glycol-chitosan (GC) and glycol-chitosan conjugated with deferoxamine (DFO), to enhance their ability to bind iron.

View Article and Find Full Text PDF

 Obstructive sleep apnea (OSA) is defined as intermittent partial or complete collapse of the upper airway during sleep. It is a common condition in childhood, with an incidence ranging from 1.2% to 5.

View Article and Find Full Text PDF

Magnetic shape-memory (MSM) Heuslers have attracted great attention in recent years for both caloric and magnetomechanical applications. Thanks to their multifunctional properties, they are also promising for a vast variety of biomedical applications. However, this topic has been rarely investigated so far.

View Article and Find Full Text PDF

Online adaptive radiotherapy aims to fully leverage the advantages of highly conformal therapy by reducing anatomical and set-up uncertainty, thereby alleviating the need for robust treatments. This requires extensive automation, among which is the use of deformable image registration (DIR) for contour propagation and dose accumulation. However, inconsistencies in DIR solutions between different algorithms have caused distrust, hampering its direct clinical use.

View Article and Find Full Text PDF

Anatomical and daily set-up uncertainties impede high precision delivery of proton therapy. With online adaptation, the daily plan is reoptimized on an image taken shortly before the treatment, reducing these uncertainties and, hence, allowing a more accurate delivery. This reoptimization requires target and organs-at-risk (OAR) contours on the daily image, which need to be delineated automatically since manual contouring is too slow.

View Article and Find Full Text PDF

Background And Purpose: Anatomical changes may compromise the planned target coverage and organs-at-risk dose in particle therapy. This study reports on the practice patterns for adaptive particle therapy (APT) to evaluate current clinical practice and wishes and barriers to further implementation.

Materials And Methods: An institutional questionnaire was distributed to PT centres worldwide (7/2020-6/2021) asking which type of APT was used, details of the workflow, and what the wishes and barriers to implementation were.

View Article and Find Full Text PDF

Background And Purpose: Organ motion compromises accurate particle therapy delivery. This study reports on the practice patterns for real-time intrafractional motion-management in particle therapy to evaluate current clinical practice and wishes and barriers to implementation.

Materials And Methods: An institutional questionnaire was distributed to particle therapy centres worldwide (7/2020-6/2021) asking which type(s) of real-time respiratory motion management (RRMM) methods were used, for which treatment sites, and what were the wishes and barriers to implementation.

View Article and Find Full Text PDF

fast and accurate contouring of daily 3D images is a prerequisite for online adaptive radiotherapy. Current automatic techniques rely either on contour propagation with registration or deep learning (DL) based segmentation with convolutional neural networks (CNNs). Registration lacks general knowledge about the appearance of organs and traditional methods are slow.

View Article and Find Full Text PDF

Background And Purpose: Model-based selection of proton therapy patients relies on a predefined reduction in normal tissue complication probability (NTCP) with respect to photon therapy. The decision is necessarily made based on the treatment plan, but NTCP can be affected when the delivered treatment deviates from the plan due to delivery inaccuracies. Especially for proton therapy of lung cancer, this can be important because of tissue density changes and, with pencil beam scanning, the interplay effect between the proton beam and breathing motion.

View Article and Find Full Text PDF

Anatomical changes during proton therapy require rapid treatment plan adaption to mitigate the associated dosimetric impact. This in turn requires a highly efficient workflow that minimizes the time between imaging and delivery. At the Paul Scherrer Institute, we have developed an online adaptive workflow, which is specifically designed for treatments in the skull-base/cranium, with the focus set on simplicity and minimizing changes to the conventional workflow.

View Article and Find Full Text PDF

While investigating the possible synergistic effect of the conventional anticancer therapies, which, taken individually, are often ineffective against critical tumors, such as central nervous system (CNS) ones, the design of a theranostic nanovector able to carry and deliver chemotherapy drugs and magnetic hyperthermic agents to the target radiosensitizers (oxygen) was pursued. Alongside the original formulation of polymeric biodegradable oxygen-loaded nanostructures, their properties were fine-tuned to optimize their ability to conjugate therapeutic doses of drugs (doxorubicin) or antitumoral natural substances (curcumin). Oxygen-loaded nanostructures (diameter = 251 ± 13 nm, ζ potential = -29 ± 5 mV) were finally decorated with superparamagnetic iron oxide nanoparticles (SPIONs, diameter = 18 ± 3 nm, ζ potential = 14 ± 4 mV), producing stable, effective and non-agglomerating magnetic nanovectors (diameter = 279 ± 17 nm, ζ potential = -18 ± 7 mV), which could potentially target the tumoral tissues under magnetic driving and are monitorable either by US or MRI imaging.

View Article and Find Full Text PDF

The experience of working on the frontlines of the COVID-19 healthcare crisis has presented a cumulative traumatic experience that affects healthcare professionals' well-being. Psychological resources such as resilience and adaptive defense mechanisms are essential in protecting individuals from severe stress and burnout. During September 2020, 233 healthcare workers responded to an online survey to test the impact of demographic variables, COVID-19 exposure, and psychological resources in determining stress and burnout during the COVID-19 emergency.

View Article and Find Full Text PDF

Deformable image registration (DIR) is an important component for dose accumulation and associated clinical outcome evaluation in radiotherapy. However, the resulting deformation vector field (DVF) is subject to unavoidable discrepancies when different algorithms are applied, leading to dosimetric uncertainties of the accumulated dose. We propose here an approach for proton therapy to estimate dosimetric uncertainties as a consequence of modeled or estimated DVF uncertainties.

View Article and Find Full Text PDF

Purpose: A major burden of introducing an online daily adaptive proton therapy (DAPT) workflow is the time and resources needed to correct the daily propagated contours. In this study, we evaluated the dosimetric impact of neglecting the online correction of the propagated contours in a DAPT workflow.

Material And Methods: For five NSCLC patients with nine repeated deep-inspiration breath-hold CTs, proton therapy plans were optimised on the planning CT to deliver 60 Gy-RBE in 30 fractions.

View Article and Find Full Text PDF

There are huge demands on multifunctional nanocarriers to be used in nanomedicine. Herein, we present a simple and efficient method for the preparation of multifunctional magnetically responsive polymeric-based nanocarriers optimized for biomedical applications. The hybrid delivery system is composed of drug-loaded polymer nanoparticles (poly(caprolactone), PCL) coated with a multilayer shell of polyglutamic acid (PGA) and superparamagnetic iron oxide nanoparticles (SPIONs), which are known as bio-acceptable components.

View Article and Find Full Text PDF

Introduction And Objective: Information on the spectrum and frequencies of pediatric neurological presentations to emergency departments is vital to optimize quality of care. The objective of this study was to determine the incidence of pediatric neurological emergencies and to analyze the impact of specialist neurological advice in emergency care.

Patients And Methods: We performed a retrospective descriptive study of pediatric emergency room visits for neurological reasons at the Timone University Hospital in Marseille over a 6-month period (from October 2017 to March 2018).

View Article and Find Full Text PDF