J Environ Sci Health A Tox Hazard Subst Environ Eng
August 2012
Two biotrickling filters were set up at two wastewater treatment plants (WWTP) in The Netherlands to investigate their effectiveness for treatment of odorous waste gases from different sources. One biotrickling filter was installed at Nieuwe Waterweg WWTP in Hook of Holland to study the hydrogen sulfide removal from headworks waste air. The other reactor was installed at Harnaschpolder WWTP (treating wastewater of the city of The Hague) to remove mercaptans and other organic compounds (odor) coming from the emissions of the anaerobic tanks of the biological nutrient removal (BNR) activated sludge.
View Article and Find Full Text PDF