Lock-in vibrothermography has proven to be very useful to characterizing kissing cracks producing ideal, homogeneous, and compact heat sources. Here, we approach real situations by addressing the characterization of non-compact (strip-shaped) heat sources produced by open cracks and inhomogeneous fluxes. We propose combining lock-in vibrothermography data at several modulation frequencies in order to gather penetration and precision data.