Introduction: Computed tomography (CT) Hounsfield units (HU) recently emerged as a promising screening tool for low bone mineral density (BMD). We hypothesized that CT HU measurements of the thoracic spine would significantly and positively correlate with dual X-ray absorptiometry (DXA) BMD scans of the femoral neck.

Materials And Methods: The study included patients with DXA scans and thoracic CT scans at the Walter Reed National Military Medical Center.

View Article and Find Full Text PDF

Introduction: Prior to being largely abandoned due to unacceptably high failure rates and the adverse physiologic reactions to metal ions, metal-on-metal (MoM) total hip arthroplasty (THA) and hip resurfacing (HR) were in widespread use throughout the USA, and the potential benefit of decreased volumetric wear rates made it of particular interest to those who serve a young active population, such as military surgeons. The aim of our study was to determine the revision rate of metal on metal hip implants performed at our military institution and obtain current patient reported outcomes from this cohort.

Materials And Methods: We conducted a retrospective review of patients who underwent MoM total hip arthroplasty (THA) or hip resurfacing (HR) at our institution from 2006 to 2012.

View Article and Find Full Text PDF