PDA stenting is increasingly utilized for patients with ductal-dependent pulmonary blood flow. Predicting optimal stent length prior to and during the intervention remains a challenge. The utility of pre-catheterization computed tomography angiography (CTA) to predict stent length was evaluated.

View Article and Find Full Text PDF

Medical tubing, particularly cardiovascular tubing, is a critical area of research where continuous improvements are necessary to advance medical devices and improve patient care. While polymers are fundamental for these applications, on their own they present several limitations such as insufficient X-ray contrasting capabilities. As such, polymer composites utilizing radiopaque fillers are a necessity for this application.

View Article and Find Full Text PDF
Article Synopsis
  • Pulmonary vein stenosis (PVS) is a rare and serious condition that can occur in children after heart transplantation (HTx), often linked to underlying congenital heart disease.* -
  • A study reviewing 422 HTx patients identified 19 with PVS, typically diagnosed a median of 2 months post-transplant, with some requiring surgery or angioplasty due to complications.* -
  • The findings highlight that PVS affects approximately 4.5% of pediatric HTx patients, emphasizing the need for close monitoring and intervention strategies for those at risk.*
View Article and Find Full Text PDF

We present the clinical course of an 8-month-old infant with a giant cutaneous hemangioma resulting in high-output heart failure and pulmonary hypertension. The lesion was successfully embolized and excised, with rapid resolution of heart failure and improvement in pulmonary hypertension.

View Article and Find Full Text PDF

A 33-year-old woman with aortic valve stenosis status-post Ross at age 6 years developed symptomatic right heart failure from right ventricle to pulmonary artery conduit stenosis. Conduit rehabilitation and transcatheter pulmonary valve replacement resulted in acute left atrial hypertension and respiratory failure requiring venoarterial extracorporeal membrane oxygenation and atrial septal defect creation as a bridge to recovery.

View Article and Find Full Text PDF

Balloon aortic valvuloplasty (BAV) is performed in children with significant aortic stenosis (AS). Traditionally, contrast angiography measures the annulus and assesses aortic regurgitation (AR) after each dilation. Echocardiographic guidance is hypothesized to reduce contrast and radiation exposure, without compromising efficacy or safety.

View Article and Find Full Text PDF
Article Synopsis
  • Neonates and infants with coronary artery fistulas (CAFs) are rare, and this study examines their outcomes post-treatment through a retrospective review.
  • Out of 48 patients analyzed, most had proximal CAFs, with high procedural success rates for both transcatheter (92%) and surgical closure (94%).
  • Follow-up results showed that while a majority had optimal coronary remodeling, those with distal CAFs experienced more complications, including symptomatic and asymptomatic thrombosis.
View Article and Find Full Text PDF

Percutaneous balloon pulmonary valvuloplasty (PBPV) is the treatment of choice for isolated pulmonary valve stenosis. While this procedure is highly efficacious and has an excellent safety profile, as currently practiced, patients are obligatorily exposed to the secondary risks of ionizing radiation and contrast media. To mitigate these risks, we developed a protocol which utilized echo guidance for portions of the procedure which typically require fluoroscopy and/or angiography.

View Article and Find Full Text PDF

Patent ductus arteriosus stenting for ductal-dependent pulmonary blood flow is a technically challenging neonatal procedure to maintain a stable pulmonary circulation. Pre-procedural computed tomography imaging aids in outlining ductal origin, insertion, size, course and curvature. Computed tomography imaging may add value to procedural outcomes and reduce overall procedural morbidity in neonatal patent ductus arteriosus stenting.

View Article and Find Full Text PDF

Intravascular stents for pediatric patients that degrade without inhibiting vessel growth remain a clinical challenge. Here, poly(L-lactide) fibers (DH-BDS) at two thicknesses, 250 μm and 300 μm, were assembled into large, pediatric-sized stents (Ø10 - Ø20 mm). Fibers were characterized mechanically and thermally, then stent mechanical properties were compared to metal controls, while mass loss and degradation kinetics modeling estimated total stent degradation time.

View Article and Find Full Text PDF

The GORE® CARDIOFORM ASD occluder (ASDO) is approved for closure of ASDs up to 35 mm diameter. With an adaptable central waist, each device size is suitable over a range of defect diameters. Understanding deployed dimensions across various defect sizes will assist operators.

View Article and Find Full Text PDF

Background: There are no established criteria to decide suitability for Fontan fenestration closure. Our institution has the following criteria: an unobstructed Fontan pathway with no significant decompressing venovenous collaterals, baseline Fontan pressure ≤15 mmHg, baseline cardiac index ≥2 L/min/m, and a decrease in cardiac index ≤20% with test occlusion of the fenestration.

Objective: The objective of the study was to review midterm outcomes following device closure of Fontan fenestration using institutional criteria.

View Article and Find Full Text PDF

Covered stents have a continually expanding spectrum of applications for patients with congenital heart disease. Here we report use of covered stents to successfully perform a first-in-human percutaneous biventricular conversion of a 1.5 ventricle Glenn palliation in an adult born with pulmonary atresia.

View Article and Find Full Text PDF

Novel commercially available software has enabled registration of both CT and MRI images to rapidly fuse with X-ray fluoroscopic imaging. We describe our initial experience performing cardiac catheterisations with the guidance of 3D imaging overlay using the VesselNavigator system (Philips Healthcare, Best, NL). A total of 33 patients with CHD were included in our study.

View Article and Find Full Text PDF

Background: Today's standard of care, in the congenital heart disease (CHD) population, involves performing cardiac catheterization under x-ray fluoroscopy and cardiac magnetic resonance (CMR) imaging separately. The unique ability of CMR to provide real-time functional imaging in multiple views without ionizing radiation exposure has the potential to be a powerful tool for diagnostic and interventional procedures. Limiting fluoroscopic radiation exposure remains a challenge for pediatric interventional cardiologists.

View Article and Find Full Text PDF

Objectives: To quantify radiation exposure during pediatric cardiac catheterizations performed by multiple operators on a new imaging platform, the Artis Q.zen (Siemens Healthcare, Forchheim, Germany), and to compare these data to contemporary benchmark values.

Background: The Artis Q.

View Article and Find Full Text PDF

Surgically paced prosthetic conduits are commonly used in the treatment of congenital heart disease. A major limitation of available prosthetic grafts is that they do not grow with the patient. We describe a human case of percutaneous balloon dilation of a surgically placed exGraft conduit (PECA Labs, Inc, Pittsburgh, PA) in a neonate with single-ventricle disease.

View Article and Find Full Text PDF

Utilization of the Melody valve for mitral valve replacement has been previously reported; however, left ventricular outflow tract obstruction is a frequent concern. In this report, a technique for supra-annular placement of the Melody valve in the mitral position is described which will minimize the risk of left ventricular outflow tract obstruction.

View Article and Find Full Text PDF

The quest for an ideal biodegradable stent for both adult coronary and pediatric congenital heart disease applications continues. Over the past few years, a lot of progress has been made toward development of a dedicated pediatric biodegradable stent that can be used for congenital heart disease applications. At present, there are no biodegradable stents available for use in congenital heart disease.

View Article and Find Full Text PDF

Background: Long-term outcomes for childhood left ventricular noncompaction (LVNC) are uncertain. We examined late outcomes for children with LVNC enrolled in a national population-based study.

Methods: The National Australian Childhood Cardiomyopathy Study includes all children in Australia with primary cardiomyopathy diagnosed before 10 years of age between 1987 and 1996.

View Article and Find Full Text PDF

Previous studies have shown that cardiac MRI can be used to evaluate the suitability for infants to undergo the Glenn operation after having undergone the Norwood procedure. We sought to analyse our institutional data retrospectively to identify whether such a policy would be advisable in the current era. We reviewed patients who underwent the Norwood procedure between 1 January, 2006 and 1 January, 2016.

View Article and Find Full Text PDF

Background: Late survival and symptomatic status of children with hypertrophic cardiomyopathy have not been well defined. We examined long-term outcomes for pediatric hypertrophic cardiomyopathy.

Methods: The National Australian Childhood Cardiomyopathy Study is a longitudinal population-based cohort study of children (0-10 years of age) diagnosed with cardiomyopathy between 1987 and 1996.

View Article and Find Full Text PDF

Adults with congenital heart disease are a growing population with increasingly more complex disease, in large part due to improvements in delivery of care to the pediatric population. Cardiac catheterization is an integral component of diagnosis and management in these patients. Careful attention to detail and a thorough understanding of intracardiac hemodynamics are critical to performing complete diagnostic evaluations.

View Article and Find Full Text PDF