Publications by authors named "Alan B Heath"

Nucleic acid amplification techniques (NAT) are routinely used for clinical diagnostics and monitoring hepatitis B virus (HBV) infections, and are implemented on a voluntary basis for blood screening. A collaborative study was performed to evaluate a replacement WHO International Standard for HBV for the standardization of NAT. Two lyophilised HBV candidates were evaluated by 16 laboratories worldwide, alongside the existing HBV International Standard.

View Article and Find Full Text PDF

Variability in viral load measurements using nucleic acid amplification techniques (NAT) has a significant impact on the management of Epstein-Barr virus (EBV)-associated diseases, and has highlighted a need for standardisation of these measurements. The aim of this collaborative study was to evaluate the suitability of a range of candidate reference materials to harmonise EBV viral load measurements in a wide range of NAT assays. Candidate materials included lyophilised and liquid whole virus preparations of the EBV B95-8 strain, and preparations of Namalwa and Raji cells.

View Article and Find Full Text PDF

Background: The WHO International Standard (IS) for hepatitis B surface antigen (HBsAg) is used to standardize HBsAg assays. Stocks of the 2nd IS for HBsAg are depleted. The proposal to establish its replacement was endorsed by WHO in 2012.

View Article and Find Full Text PDF

Background: Interassay harmonization of cytomegalovirus (CMV) DNA measurement is important for infection management. Uncertainty exists regarding the result harmonization achievable in patient plasma samples using quantitative polymerase chain reaction (qPCR) assays with calibrators now traceable to the First World Health Organization International Standard (IS) for CMV DNA.

Method: Serial dilutions of the IS and a blinded panel of 40 genotyped CMV DNA-positive pooled plasma samples and 10 negative plasma samples were tested by 6 laboratories using 10 qPCR assays calibrated to the IS.

View Article and Find Full Text PDF

Variability in the performance of nucleic acid amplification technology (NAT)-based assays presents a significant problem in the diagnosis and management of human cytomegalovirus (HCMV) infections. Here we describe a collaborative study to evaluate the suitability of candidate reference materials to harmonize HCMV viral load measurements in a wide range of NAT assays. Candidate materials comprised lyophilized Merlin virus, liquid Merlin virus, liquid AD169 virus, and purified HCMV Merlin DNA cloned into a bacterial artificial chromosome.

View Article and Find Full Text PDF

Two candidate preparations of human sequence recombinant Interleukin-2 (IL-2) were formulated and lyophilized at NIBSC prior to evaluation in a collaborative study for their suitability to serve as a replacement international standard. The preparations were tested by eight laboratories using in vitro bioassays and immunoassays. The candidate preparation 86/500 was judged suitable to serve as a replacement international standard based on the data obtained for activity and stability.

View Article and Find Full Text PDF

One candidate preparation of human sequence recombinant transforming growth factor-β3 (TGF-β3) was formulated and lyophilized at NIBSC prior to evaluation in a collaborative study for its suitability to serve as an international standard. The preparation was tested by 8 laboratories using in vitro bioassays and immunoassays. The candidate preparation 09/234 was judged suitable to serve as an international standard based on the data obtained for biological activity and stability.

View Article and Find Full Text PDF

Five candidate preparations of human sequence recombinant granulocyte-colony stimulating factor (G-CSF) were formulated and lyophilized at NIBSC prior to evaluation in a collaborative study for their suitability to serve as a replacement International Standard (IS). The preparations were tested by 13 laboratories using in vitro bioassays. The candidate preparation 09/136 was judged suitable to serve as a replacement international standard based on the data obtained for biological activity and stability.

View Article and Find Full Text PDF

A World Health Organization collaborative study was conducted to evaluate candidate international standards for human papillomavirus (HPV) Type 16 DNA (NIBSC code 06/202) and HPV Type 18 DNA (NIBSC code 06/206) for use in the amplification and detection steps of nucleic acid-based assays. The freeze-dried candidate international standards were prepared from bulk preparations of cloned plasmid containing full-length HPV-16 or HPV-18 genomic DNA. Nineteen laboratories from 13 countries participated in the study using a variety of commercial and in-house quantitative and qualitative assays.

View Article and Find Full Text PDF

Background: In order to harmonize results for the detection and quantification of Plasmodium falciparum DNA by nucleic acid amplification technique (NAT)-based assays, a World Health Organization (WHO) collaborative study was performed, evaluating a series of candidate standard preparations.

Methods: Fourteen laboratories from 10 different countries participated in the collaborative study. Four candidate preparations based upon blood samples parasitaemic for P.

View Article and Find Full Text PDF

Folate measurements, particularly for whole blood, show wide inter-laboratory and inter-methodology variability. This variability appears to be due in part to the lack of internationally accepted reference materials. A whole blood haemolysate, lyophilised in ampoules and designated 95/528, was therefore evaluated by 15 laboratories in five countries for its suitability as an International Standard (IS) for whole blood folate.

View Article and Find Full Text PDF