Background: Hepatitis B viral load monitoring is an essential part of managing patients with chronic Hepatits B infection. Beckman Coulter has developed the VERIS HBV Assay for use on the fully automated Beckman Coulter DxN VERIS Molecular Diagnostics System. OBJECTIVES: To evaluate the analytical performance of the VERIS HBV Assay at multiple European virology laboratories.

View Article and Find Full Text PDF

Background: Hepatitis B viral load testing is essential to treatment and monitoring decisions in patients with chronic Hepatitis B. Beckman Coulter has developed the VERIS HBV Assay (Veris) for use on the fully automated DxN VERIS Molecular Diagnostics System. OBJECTIVES: To evaluate the clinical performance of the Veris HBV Assay at multiple EU laboratories STUDY DESIGN: Method comparison was performed with a total of 344 plasma specimens from HBV infected patients tested with Veris and COBAS TaqMan HBV Test (Cobas), 207 specimens tested with Veris and RealTime HBV Assay (RealTime), 86 specimens tested with Veris and VERSANT HBV Assay (Versant), and 74 specimens tested with Veris and artus HBV RG PCR kit (artus).

View Article and Find Full Text PDF

Background: Viral load monitoring is essential for patients under treatment for HIV. Beckman Coulter has developed the VERIS HIV-1 Assay for use on the novel, automated DxN VERIS Molecular Diagnostics System. OBJECTIVES: Evaluation of the clinical performance of the new quantitative VERIS HIV-1 Assay at multiple EU laboratories.

View Article and Find Full Text PDF

The analytical performance of the Veris HIV-1 assay for use on the new, fully automated Beckman Coulter DxN Veris molecular diagnostics system was evaluated at 10 European virology laboratories. The precision, analytical sensitivity, performance with negative samples, linearity, and performance with HIV-1 groups/subtypes were evaluated. The precision for the 1-ml assay showed a standard deviation (SD) of 0.

View Article and Find Full Text PDF

Background: Beckman Coulter has developed the VERIS HCV Assay for use on the new fully automated DxN VERIS Molecular Diagnostic System for HCV viral load monitoring.

Objectives: Evaluate the clinical performance of the new quantitative VERIS HCV Assay.

Study Design: Comparison was performed on 279 plasma specimens from HCV infected patients tested with the VERIS HCV Assay and COBAS Ampliprep/COBAS Taqman HCV Test and 369 specimens tested with the VERIS HCV Assay and RealTime HCV Assay.

View Article and Find Full Text PDF

The analytical performance of the Veris HCV Assay for use on the new and fully automated Beckman Coulter DxN Veris Molecular Diagnostics System (DxN Veris System) was evaluated at 10 European virology laboratories. Precision, analytical sensitivity, specificity, and performance with negative samples, linearity, and performance with hepatitis C virus (HCV) genotypes were evaluated. Precision for all sites showed a standard deviation (SD) of 0.

View Article and Find Full Text PDF

Background: Accurate detection of Hepatitis B Surface Antigen (HBsAg) is an important aid in the diagnosis of patients infected with the hepatitis B virus (HBV). A multi-center study was conducted to characterize the performance of the HBsAg assay on the family of Access immunoassay systems from Beckman Coulter.

Methods: The Access HBsAg assay was characterized in a multi-center study and compared to the Abbott AxSYM* and PRISM* HBsAg assays.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionkvl9s8lioceafclu03g5rqnsck4d7dal): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once