This study evaluates the operational status of twenty-six biofilter facilities across nine cities in Sweden, with respect to their functional design criteria, engineered design features (filter media composition, hydraulic conductivity, and drawdown time), and includes a visual inspection of the biofilter components (pre-treatment, in/outlet structures, filter media, and vegetation). These indicators were used to examine the performance level of each biofilter in achieving their design objectives set by the operators. Furthermore, it was investigated whether the biofilter facilities had been properly maintained to meet the objectives.
View Article and Find Full Text PDFThe carbon sequestration services of stormwater wet retention ponds were investigated in four different climates: U.S., Northern Sweden, Southern Sweden, and Singapore, representing a range of annual mean temperatures, growing season lengths and rainfall depths: geographic factors that were not statistically compared, but have great effect on carbon (C) accumulation.
View Article and Find Full Text PDFThe surface infiltration rates (SIR) of permeable pavements decline with time as sediment and debris clog pore spaces. Effective maintenance techniques are needed to ensure the hydraulic functionality and water quality benefits of this stormwater control. Eight different small-scale and full-scale maintenance techniques aimed at recovering pavement permeability were evaluated at ten different permeable pavement sites in the USA and Sweden.
View Article and Find Full Text PDF