Purpose: The purpose of this study was to compare the wear, fracture strength, and mode of failure of various brands of 3D-printed resin denture teeth with prefabricated acrylic resin. Additionally, the study aimed to analyze the different modes of failure exhibited by these teeth.

Materials And Methods: The study utilized 90 3D-printed and 30 prefabricated, 3D-printed resin teeth from three brands: L = Optiprint Lumina, A = ASIGA DentaTooth, P = Power resins, along with prefabricated acrylic teeth from M = Major Super Lux.

View Article and Find Full Text PDF

Purpose: This study investigated the impact of preparation design and material types on fracture strength in maxillary premolars endocrowns after thermodynamic aging.

Materials And Methods: Eighty two-rooted maxillary premolar crowns underwent endodontic treatment (N = 80, n = 10). The teeth were categorized into ten groups (4-mm deep with no intracanal extension lithium disilicate glass ceramic & multilayer zirconia endocrowns (LE0 & ZE0); 4-mm deep with 4-mm intracanal extension in one canal (LE1 & ZE1); 4-mm deep with 2-mm intracanal extensions in both canals (LE2 & ZE2); flat overlays with no endocore (LO & ZO); glass fiber reinforced post & core and crown (LC & ZC)).

View Article and Find Full Text PDF

To assess the clinical periodontal status of abutment teeth in regards of different design components of distal-extension removable partial dentures. Subjects (N=100) with acrylic or cobalt-chromium distal-extension removable partial dentures were enrolled and their periodontal parameters plaque and gingival indices [PI, GI], probing depths [PD], clinical attachment loss [CAL] and a mobility index [MI] evaluated. Denture base type, major connector, occlusal rests position, design of direct retainers, retention, stability and denture wearing habits were further evaluated.

View Article and Find Full Text PDF

The long-term success of ceramic laminate veneers (CLVs) is influenced by the marginal and internal fit of the restorations. However, studies comparing the fit of CLVs using different intraoral scanners or the indirect digitization technique are lacking. The purpose of this study was therefore to assess the marginal and internal fit of CAD/CAM-milled CLVs using different intraoral scanners and the indirect digitalization technique.

View Article and Find Full Text PDF

Purpose: The purpose of this in-vitro study was to investigate the effect of framework design on fracture resistance and failure modes of cantilever inlay-retained fixed partial dentures (IRFDPs) fabricated from two multilayered monolithic zirconia materials.

Materials And Methods: Seventy-two natural premolar teeth were prepared as abutments for cantilever IRFDPs using three designs: mesial-occlusal (MO) inlay with short buccal and palatal wings (D1), MO inlay with long palatal wing (D2), MO inlay with long palatal wing and occlusal extension (D3). Full-contoured IRFDPs were fabricated from two monolithic zirconia materials; IPS e.

View Article and Find Full Text PDF

Purpose: To study the surface and mechanical properties of 3D printed denture-base resin materials and compare them with conventional heat-cured polymethylmethacrylate (PMMA).

Materials And Methods: Three brands of 3D printed denture-base resin materials and one conventional heat-cured PMMA were tested in this study: NextDent 3D printed resin, Dentona 3D printed resin, ASIGA 3D printed resin, and Meliodent conventional PMMA. Sixty specimens (25 × 25 × 3 mm) were fabricated (n=15 per group) to perform the following tests: wettability, surface roughness, and microhardness.

View Article and Find Full Text PDF

Purpose: To evaluate the effect of repetitive milling on the surface roughness of ceramic crowns.

Materials And Methods: Twenty feldspathic ceramic crowns (VITABLOCS Mark II; Vita Zahnfabrik, Bad Säckingen, Germany) milled with hard milling protocol, and 20 zirconia crowns (5Y-TZP, inCoris TZI; Dentsply Sirona, York, PA) milled with soft milling protocol, using a 5-axis milling machine (inLab MC X5; Dentsply Sirona) were investigated. Atomic force microscopy (SPM SmartSPM™-1000) was used for surface roughness measurements (Ra, RMS).

View Article and Find Full Text PDF

Statement Of Problem: Limited information is available on the effect of LOCATOR abutment length and luting cement type on retention to intraradicular dentin in overdentures.

Purpose: The purpose of this in vitro study was to evaluate the effect of the length of a commercially available LOCATOR abutment and cement type on retention in the root canal.

Material And Methods: Eighty LOCATOR abutments with a standard length of 6 mm were obtained.

View Article and Find Full Text PDF

Purpose: To compare surface properties of 2 brands of pre-polymerized resin blocks for complete dentures (CAD/CAM PMMA) to conventional heat-polymerized PMMA.

Materials And Methods: A total of 45 rectangular specimens (25 × 25 × 3 mm) were fabricated from 3 brands of PMMA (n = 15/group): AvaDent CAD/CAM PMMA, Tizian-Schütz CAD/CAM PMMA, Meliodent conventional PMMA. Specimens were examined for wettability using the sessile drop method, surface roughness using a digital contact profilometer, and microhardness using Vickers hardness number.

View Article and Find Full Text PDF

Statement Of Problem: The marginal and internal adaptations of porcelain laminate veneers (PLVs) are key elements in their long-term success. However, the marginal and internal fit obtained with a pressable material compared with computer-aided design and computer-aided manufacturing (CAD-CAM) needs further investigation as does the choice of cement used.

Purpose: The purpose of this in vitro study was to evaluate the marginal and internal fit of PLVs fabricated using pressing and CAD-CAM milling and cemented using 2 types of composite resin cement.

View Article and Find Full Text PDF

Purpose: The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology to the field of removable prosthodontics has recently made it possible to fabricate complete dentures of prepolymerized polymethyl methacrylate (PMMA) blocks, which are claimed to be of better mechanical properties; however, no published reports that have evaluated mechanical properties of CAD/CAM PMMA. The purpose of this study was to compare flexural strength, impact strength, and flexural modulus of two brands of CAD/CAM PMMA and a conventional heat-cured PMMA.

Materials And Methods: 45 rectangular specimens (65 mm × 10 mm × 3 mm) were fabricated (15 CAD/CAM AvaDent PMMA specimens from AvaDent, 15 CAD/CAM Tizian PMMA specimens from Shütz Dental, 15 conventional Meliodent PMMA specimens from Heraeus Kulzer) and stored in distilled water at (37  ± 1°C) for 7 days.

View Article and Find Full Text PDF

Objective: To assess possible associations between torus palatinus (TP), torus mandibularis (TM), occlusal force (OF), Klemetti's classes, mandibular cortical index (MCI), and sociodemographic variables in a selected sample of Jordanians. Previous studies have suggested that oral tori are benign anatomical variations probably related to several factors such as functional stress, gender predisposition, number of teeth present, and nutritional factors.

Method And Materials: A total of 130 Jordanian adults were included.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate heat generation at the implant surface caused by abutment preparation using a diamond bur in a high-speed dental turbine in vitro at 2 different water-coolant temperatures.

Materials And Methods: Thirty-two titanium-alloy abutments were connected to a titanium-alloy implant embedded in an acrylic resin placed within a water bath at a controlled temperature of 37°C. The specimens were equally distributed into 2 groups (16 each).

View Article and Find Full Text PDF

Statement Of Problem: Currently, no standard luting protocol exists for fiber posts. In addition, no agreement has been reached on the time interval between canal obturation and post space preparation and cementation.

Purpose: The purpose of this in vitro study was to evaluate the retention of fiber posts cemented with 3 different types of cement: Paracore, Variolink II, and RelyX Unicem cement after 24 hours or 2 weeks in root canals obturated with gutta percha and a eugenol-based sealer.

View Article and Find Full Text PDF

Objectives: To evaluate teeth preparation designs for metal-ceramic crowns in private dental practice in Jordan.

Materials And Methods: One-hundred and seventy two dies were included. Different aspects of tooth preparations were quantified, analyzed and compared with the recommended guidelines.

View Article and Find Full Text PDF

Objective: The purpose of this study was to compare the effect of eugenol-based and resin-based endodontic sealers on the push-out bond strengths of prefabricated fiber posts luted with different resin cements.

Method And Materials: Ninety prefabricated fiber posts were luted into extracted singlerooted teeth with one of three resin cements (Variolink II, ParaCore, or Rely X Unicem). Each group was subdivided into three groups with 10 teeth each.

View Article and Find Full Text PDF

Statement Of The Problem: The outline shapes of the dental arch, face, and tooth are esthetic factors used to determine the proper form of artificial teeth when selected for artificial prostheses.

Purpose: The purpose of this study was to investigate the quantitative relationships between the outlines of the face, the maxillary central incisor, and the maxillary arch by using Fourier analysis.

Material And Methods: Frontal facial photographs and irreversible hydrocolloid impressions of the maxilla were obtained from 200 young, dentate individuals (100 men, 100 women) ages 22 to 28 years.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to examine the relationship between skin color (shade) and tooth shade under standard and nonstandard illumination sources.

Materials And Methods: Four hundred Jordanian participants (200 males, 200 females, 20 to 50 years of age) were studied. Skin colors were assessed and categorized using the L'Oreal and Revlon foundation shade guides (light, medium, dark).

View Article and Find Full Text PDF

Purpose: To assess removable denture patient awareness, expectations, and source of information about dental implants (DIs).

Materials And Methods: Three hundred patients [150 removable partial denture (RPD) wearers and 150 complete denture wearers (CDWs)] attended the removable prosthodontic clinic at Faculty of Dentistry, Jordan University of Science and Technology. Patients were evaluated using a pilot-tested, 21-question questionnaire.

View Article and Find Full Text PDF

Statement Of Problem: Fiber posts can fail because of loss of retention; and it is unknown which luting agent provides the highest bond strength.

Purpose: The purpose of this study was to investigate the tensile bond strength of glass fiber posts luted to premolar teeth with 6 resin composite luting agents.

Material And Methods: Ninety-six single-rooted extracted human mandibular premolars were sectioned 2 mm coronal to the most incisal point of the cementoenamel junction.

View Article and Find Full Text PDF

The appropriate convergence angle (CA) for adequate retention and resistance of cast crowns has always been a matter of research and discussion. The purpose of this study was to measure the CA of tooth preparation for single crown (SC) or as abutments for fixed partial denture (FPD) carried out by final-year undergraduate dental students at the College of Dentistry, King Saud University and to compare them with the recommended CA. The convergence angles of 355 tooth preparations were evaluated and grouped into SC preparations and FPD abutment preparations.

View Article and Find Full Text PDF

The purpose of this study was to determine the possible effects of the veneering porcelain thickness, and of repeated firing on the final shade of IPS e.max Press. Sixty disc-shaped IPS e.

View Article and Find Full Text PDF

The purpose of the study was to evaluate the effect of water flow rate on the heat transmission in implants during abutment preparation using a diamond bur in a high-speed dental turbine. Titanium-alloy abutments (n = 32) were connected to a titanium-alloy implant embedded in an acrylic resin within a water bath at a controlled temperature of 37°C. The specimens were equally distributed into 2 groups (16 each) according to the water flow rate used during the preparation phase.

View Article and Find Full Text PDF

Purpose: There is limited information in the literature regarding the effect of different endodontic sealers on the bond strength of fiber posts luted with core buildup materials. The purpose of this study was to evaluate the effect of three different root canal sealers on the retentive strength of prefabricated fiber posts luted with a composite resin cement.

Materials And Methods: Fifty-four extracted single-rooted mandibular premolar teeth were prepared and randomly divided into three groups.

View Article and Find Full Text PDF

Objectives: To investigate the prevalence of dry mouth in a select sample of edentulous Jordanian older population wearing complete dentures and to evaluate its impact on oral functions.

Background: The prevalence and impact of Xerostomia as a cofactor in causing denture problems in Jordanians have not been previously investigated.

Materials And Methods: This study included 455 participants (253 men and 202 women).

View Article and Find Full Text PDF