Objectives: This study investigates longevity of glass ionomer restorations in an older adult population.
Methods: This was a retrospective study based on clinical records. Patient records for 3,665 restorations in 1,777 adults 65 or older who had received a restoration between 12th July 2016 and 20th October 2022 were extracted from the electronic dental records system of the University of Iowa College of Dentistry and Dental Clinics.
Computer-aided design and computer-aided manufacturing (CAD/CAM) dentistry have significantly changed workflows in recent years. Restorations and devices can now be digitally designed and 3D-printed for dental care purposes. This clinical case report provides straightforward protocols for the digital design and 3D manufacture of gingivectomy and tooth preparation guides.
View Article and Find Full Text PDFThis report describes multidisciplinary care combining orthodontics and restorative dentistry for a patient with Class II occlusion and stained mandibular and maxillary resin composite veneers. The orthodontic treatment improved severe overjet and malocclusion prior to restorative care. Occlusal assessment was provided with a novel digital device (PlaneSystem, Zirkonzahn) that is integrated with digital workflows for the evaluation of the occlusal plane and condylar path inclination.
View Article and Find Full Text PDFThe biaxial flexural strength of universal shade and conventional dental resin-based composites before and after alkaline degradation was investigated. Disk samples were prepared from these resin-based composites, and some of the specimens were immersed in 0.1 M NaOH solution to create deteriorated samples.
View Article and Find Full Text PDFPurpose: This study evaluated the fracture resistance of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate crown, onlay, and non-anatomical occlusal veneer (A-OV) with and without margin fabricated.
Materials And Methods: Sixty-four CAD-CAM lithium disilicate restorations were designed as (1) complete coverage crown (CCC); (2) A-OV with margin; (3) non-A-OV with margin (NA-OV-M); and (4) non-A-OV without margin (NA-OV-NM), 16 of each. Restorations were crystallized and adhesively luted to resin dies using resin cement.
Purpose: To investigate the effect of painless low-power Er:YAG laser irradiation of conventional and polymer-infiltrated ceramic network (PICN) type CAD-CAM resin-based composites (RBCs) on resin bonding.
Methods: An Er:YAG laser system, phosphoric acid etchant, universal adhesive, RBC, and two types of CAD-CAM RBC block were used. Microtensile bond strength, fracture mode, scanning electron microscopy (SEM) observations of bonding interfaces and CAD-CAM surfaces, and surface roughness of ground and pretreated surfaces were investigated.
To evaluate the degree of conversion (DC), surface hardness (SH), and flexural strength (FS) of resin-based core build-up materials. Core build-up materials used were: MultiCore Flow (MCF); Activa (ACT); Core-X Flow (CXF); and everX flow (EVX), and DC, SH and FS were measured. An increase of DC was identified for all materials post-cure, except for EVX.
View Article and Find Full Text PDFObjectives: The present case report describes the atraumatic extraction of a primary maxillary right canine followed by immediate implant placement with a customized zirconia abutment and monolithic ultra-translucent zirconia (5Y-PSZ) crown.
Clinical Considerations: A 31-year-old patient presented to the clinic with the primary concern of mobility and gingival inflammation around the maxillary right canine. After clinical evaluation, the tooth was found to be a primary retained tooth that presented grade 3 mobility and gingival inflammation.
Background: Zirconia is a widely used material in the dental industry due to its excellent mechanical and aesthetic properties. Recently, a new 3D printing process called suspension-enclosing projection stereolithography (SEPS) was introduced to fabricate zirconia dental restorations. However, the effect of the sintering time and temperature on the properties of zirconia produced via SEPS has not been fully investigated.
View Article and Find Full Text PDFPurpose: To compare the fracture resistance of five different groups of chairside CAD/CAM molar crowns fabricated from various lithium disilicate ceramic materials (LDC): one conventional precrystallized CAD/CAM LDC, two novel precrystallized LDCs, and one fully crystallized LDC tested both with and without optional sintering.
Materials And Methods: A total of 60 chairside CAD/CAM lithium disilicate molar crowns (n = 12 per group) with 1.5-mm occlusal thickness and a 1.
This study aimed to compare the surface finish of milled leucite-reinforced ceramics polished with ceramic and composite polishing systems based on the manufacturers' recommendations. Sixty subtractive computer-aided manufactured (s-CAM) leucite-reinforced glass-ceramic specimens (IPS-Empress-CAD) were assigned into six groups: no polishing, a ceramic polishing kit, and four composite kit groups. The roughness average (Ra) was evaluated in microns using a profilometer, and scanning electron micrographs were obtained for qualitative analysis.
View Article and Find Full Text PDFThe aim of this study is to evaluate the effect of over-the-counter (OTC) at-home whitening products with LED light on partially- and fully-crystalized CAD/CAM lithium disilicate ceramics. Two partially-crystalized CAD/CAM lithium disilicate ceramics, Amber Mill and IPS e.max CAD, and one fully-crystalized CAD/CAM lithium disilicate ceramic, n!ce Straumann, were used.
View Article and Find Full Text PDFPurpose: The purpose of this study was to compare student performance in removable partial denture (RPD) design during a pre-clinical RPD course with and without using a recently developed computer software named AiDental. Additionally, student perceptions associated with the use of this software were assessed.
Methods: The AiDental software consists of a learning environment containing an RPD design system that automatically designs RPDs based on the user's input.
J Funct Biomater
March 2023
Dental implants have become a well-established treatment modality for the management of complete and partial edentulism. Recent advancements in dental implant systems and CAD/CAM technologies have revolutionized prosthodontic practice by allowing for the predictable, efficient, and faster management of complex dental scenarios. This clinical report describes the interdisciplinary management of a patient with Sjogren's syndrome and terminal dentition.
View Article and Find Full Text PDFMinimally invasive dentistry is a considered process that requires the clinician to be prepared with the ideal sequence and the tools needed. This report describes a well-planned ultraconservative approach using only two ceramic laminate veneers for the maxillary central incisors to significantly improve the patient's overall smile. A 30-year-old female presented with the chief complaints of having diastemas between the central and lateral incisors as well as incisal wear.
View Article and Find Full Text PDFThe report describes a technique using a diagnostic mock-up as a crown-lengthening surgical guide to improve the gingival architecture. The patient's primary concern was improving her smile due to her "gummy smile" and short clinical crowns. After clinical evaluation, surgical crown lengthening accompanied by maxillary central full-coverage single-unit prostheses and lateral incisor veneers was recommended.
View Article and Find Full Text PDFThe purpose of this study is to compare bond durability, in terms of fatigue bond strength, of a two-step HEMA-free universal adhesive and representative adhesives in each systematic category. The adhesives used in this study were OptiBond FL, Prime&Bond NT, Clearfil SE Bond 2, G2-Bond Universal, and Scotchbond Universal Plus Adhesive. Fatigue bond strength testing and scanning electron microscopy analysis of adhesively bonded enamel and dentin interfaces were performed.
View Article and Find Full Text PDFOne technique for placing of resin-based composite for large posterior cavities is the use of short fiber-reinforced resin-based composite (SFRC) to replace dentin in a biomimetic approach. As endurance under mastication cycles is a significant consideration in the clinical success of resin-based composite posterior restorations, the use of SFRC as a base material may prevent restorative fracture due to the fibers' effectiveness in stopping cracks. This review article specifies the characteristics of SFRC and describes the major underlying mechanisms of short fiber reinforcement for resin-based composite.
View Article and Find Full Text PDFThis study uses fracture tests and fractographical analysis to compare computer-aided design and computer-aided manufacturing (CAD/CAM) lithium disilicate molar crowns with the previous occlusal thickness recommendation of 1.5-mm, the new recommendation of 1.0-mm, and a less invasive thickness of 0.
View Article and Find Full Text PDFNumerous laboratory evaluations have been conducted since Dr. Rafael Bowen introduced a method for determining the bond strengths of adhesive systems to dental substrates in 1965. Most of the past studies have been conducted using static bond strength tests, such as shear and tensile bond strength testing with either macro or micro sized specimens.
View Article and Find Full Text PDFAim: To evaluate light transmission in a novel chairside CAD/CAM lithium disilicate ceramic with different thicknesses and with and without polishing.
Materials And Methods: Sixty flat samples (10 specimens/group) were fabricated from novel chairside CAD/CAM lithium disilicate ceramic blocks (Amber Mill, Hass Bio) with different thicknesses and with and without polishing as follows: (1) 1.0 mm thickness without polishing (1.