Purpose: High-risk patients can be identified by preprocedural computed tomography (CT) before lead extraction. However, CT evaluation may be difficult especially for lead tip identification due to artifacts in the leads. Selective right ventriculography (RVG) may enable preprocedural evaluation of lead perforation.
View Article and Find Full Text PDFChem Pharm Bull (Tokyo)
February 2021
Malaria disease remains a serious worldwide health problem. In South-East Asia, one of the malaria infection "hot-spots," medicinal plants such as Piper betle have traditionally been used for the treatment of malaria, and allylpyrocatechol (1), a constituent of P. betle, has been shown to exhibit anti-malarial activities.
View Article and Find Full Text PDFBackground: In heart failure (HF) patients implanted with high-energy devices, worsening of HF can be diagnosed from intrathoracic impedance (ITI) before symptoms appear. Early therapeutic intervention can prevent HF worsening, but the optimal intervention remains unknown. This study aimed to examine which lifestyle modifications or medications can improve HF indicators in asymptomatic HF patients diagnosed from ITI.
View Article and Find Full Text PDFBackground: The increase in the use of cardiac implantable electronic devices (CIEDs) has been associated with an increase in CIED-related infections. Transvenous lead extraction is safe and effective for patients with CIED-related infections; however, the mortality rate in these patients is high. The prognosis after transvenous lead extraction in Japanese patients, especially those with lead-related infective endocarditis, has not been evaluated.
View Article and Find Full Text PDFObjective Remote monitoring (RM) of cardiac implantable electric devices (CIEDs) has been advocated as a healthcare standard. However, expert consensus statements suggest that all patients require annual face-to-face follow-up consultations at outpatient clinics even if RM reveals no episodes. The objective of this study was to determine the critical event rate after CIED implantation through RM.
View Article and Find Full Text PDFBackground: Remote monitoring (RM) has been advocated as the new standard of care for patients with cardiovascular implantable electronic devices (CIEDs). RM has allowed the early detection of adverse clinical events, such as arrhythmia, lead failure, and battery depletion. However, lead failure was often identified only by arrhythmic events, but not impedance abnormalities.
View Article and Find Full Text PDFBackground: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is recognized as a viable alternative to the transvenous ICD. The safety and efficacy of this device has been demonstrated in Western countries, but studies with S-ICD implantation in Japanese patients have not been reported.
Methods And Results: Twelve patients received an S-ICD implant in our institute between February and September 2016.
Objective: Non-valvular atrial fibrillation (NVAF) is frequently complicated by thromboembolism. Left atrial appendage (LAA) flow is a predictor of LAA thrombosis. LAA flow is measured by transesophageal echocardiography (TEE), which is a semi-invasive diagnostic tool.
View Article and Find Full Text PDFBackground: Ambulatory measurement of intrathoracic impedance (ITI) with an implanted device has potential to assess fluid accumulation in patients with heart failure (HF), but it has failed to reduce HF-related hospitalization because of a high false-positive rate.
Objective: We aimed to examine whether a modified algorithm (OptiVol 2.0) could reduce false-positive HF events documented in our multicenter trial (MOMOTARO).
A 7-year-old boy presented at our hospital with syncope. At birth, electrocardiography had shown a long QT interval with torsade de pointes (TdP). Congenital long QT syndrome (LQTS) had been diagnosed by genetic testing, and was successfully controlled with oral propranolol.
View Article and Find Full Text PDFBackground: An early failure of the Biotronik Linox S/SD implantable cardioverter-defibrillator (ICD) lead has been reported. We have also experienced several cases with early failure of Linox leads.
Objective: Our aim was to assess the longevity of Linox S/SD (Biotronik, Berlin, Germany) compared with Sprint Fidelis (Medtronic, Minneapolis, MN), Sprint Quattro (Medtronic), and Endotak Reliance (Boston Scientific, Natick, Massachusetts) leads.
T wave oversensing (TWOS) is a common cause of inappropriate implantable cardioverter-defibrillator (ICD) therapies. Various algorithms to avoid inappropriate ICD therapy are available; however, they are not helpful to avoid TWOS. Although the reproduction of TWOS is useful to resolve the problem of TWOS, it is sometimes difficult to reproduce TWOS.
View Article and Find Full Text PDFBackground: In order to minimize inappropriate shocks of subcutaneous implantable cardioverter-defibrillators (S-ICD), it is important to recognize who is suitable for S-ICD indication. This study aimed to clarify what types of cardiac disease are likely to fulfill the S-ICD screening criteria and ineligible factors for S-ICD in the standard 12-lead electrocardiogram (ECG).
Methods: A total of 348 patients with heart disease were enrolled.
Light and temperature affect state transitions through changes in the plastoquinone (PQ) redox state in photosynthetic organisms. We demonstrated that light and/or heat treatment induced preferential photosystem (PS) I excitation by binding light-harvesting complex II (LHCII) proteins. The photosystem of wheat was in state 1 after dark overnight treatment, wherein PQ was oxidized and most of LHCII was not bound to PSI.
View Article and Find Full Text PDFPhotosystems of higher plants alleviate heat-induced damage in the presence of light under moderate stressed conditions; however, in the absence of light (i.e., in the dark), the same plants are damaged more easily.
View Article and Find Full Text PDFThe reaction of 1-(p-hydroxyaryl)cyclobutanols and phenyl iodide(III) diacetate in hexafluoroisopropanol and water produced spiro cyclohexadienone lactones via a domino reaction.
View Article and Find Full Text PDF© LitMetric 2025. All rights reserved.