Publications by authors named "Ajay S Raman"

Introduction: Left main stem percutaneous coronary intervention (LMS-PCI) is a complex high-risk procedure which can be performed as an alternative to coronary artery bypass graft (CABG) procedure in surgical turn-down patients or where there is equipoise in percutaneous versus surgical strategies. Current guidelines suggest that PCI is an appropriate alternative to CABG in patients with unprotected LMS disease and low SYNTAX score. However, "real world" data on outcomes of LMS-PCI remain limited.

View Article and Find Full Text PDF

A few case reports and case series have documented the outcomes in patients with tricuspid bioprosthetic valvular degeneration who underwent transcatheter implantation of the Medtronic Melody and the Edwards Sapien XT and Sapien 3 valves. In this report, we describe the case of a 49-year-old woman with severe bioprosthetic tricuspid valvular stenosis and multiple comorbidities who underwent transcatheter tricuspid valve replacement with a Sapien 3 valve.

View Article and Find Full Text PDF

Carcinoid heart disease presents as right-sided heart failure attributable to the dysfunction of the tricuspid and pulmonary valves. Although surgical valve replacement is the mainstay of treatment when patients become symptomatic, it is associated with substantial perioperative mortality rates. We present a case of severe pulmonary valve stenosis secondary to carcinoid heart disease, treated successfully with percutaneous valve replacement.

View Article and Find Full Text PDF

The use of subcutaneous implantable cardioverter-defibrillators is a novel option for preventing arrhythmia-mediated cardiac death in patients who are at risk of endovascular-device infection or in whom venous access is difficult. However, the potential for electromagnetic interference between subcutaneous defibrillators and left ventricular assist devices is largely unknown. We report the case of a 24-year-old man in whom we observed no electromagnetic interference between a subcutaneous implanted cardioverter-defibrillator and a HeartMate II Left Ventricular Assist System, at 3 different pump speeds.

View Article and Find Full Text PDF

Electrophysiologic procedures in the young engender concern about the potential long-term effects of radiation exposure. This concern is manifold if such procedures are contemplated during pregnancy. Catheter ablations in pregnancy are indicated only in the presence of an unstable tachycardia that cannot be controlled by antiarrhythmic agents.

View Article and Find Full Text PDF