The use of hybrid abutment crowns bonded extraorally to a titanium bonding base has aesthetic and biological benefits for the prosthetic rehabilitation of oral implants. The objective of this study was to evaluate the effects of luting agents between a zirconium dioxide crown and the titanium bonding base on crown/abutment retention and the subsequent durability of the prosthetic superstructure. Fifty-six implant abutment samples, all restored with a lower first premolar zirconium dioxide crown, were used and divided into seven groups ( = 8/group) according to the type of luting agent used: group 1, SpeedCEM Plus; group 2, Panavia SA Cement Universal; group 3, Panavia V5; group 4, RelyX Unicem 2 Automix; group 5, VITA ADIVA IA-Cem; group 6, Ketac CEM; and group 7, Hoffmann's Phosphate Cement.
View Article and Find Full Text PDFThe use of screwless Morse taper implant−abutment connections (IAC) might facilitate the clinician’s work by eliminating the mechanical complications associated with the retention screw. The aim of this study is to evaluate the effect of artificial chewing on the long-term stability of screwless Morse taper IACs. Thirty-two implant abutments restored with an upper central incisor zirconia crown were used and divided into four groups according to the implant−abutment assembling manner (C1,H: screw retained (20 Ncm); C2: tapped; or C3: torqued (20 Ncm; the screws were removed before the dynamic loading)).
View Article and Find Full Text PDFObjective: This study evaluates the effect of dynamic-loading on the microgap of the IAC when different supratructure heights are applied.
Materials And Methods: Forty-eight dental implants (24 each of butt-joint (H) and internal-conical connections (C)) were tested in this study. Each group was further divided into three groups (n = 8) according to the applied suprastructure height (H1, C1: 10 mm, H2, C2: 14 mm and H3, C3: 18 mm).
Background And Aim: Long-term edentulism associated with vertical loss of alveolar bone might lead to increased suprastructure height. This study aimed to evaluate the effect of suprastructure height on the stability of the implant-abutment connection by investigating the stability of two different two-piece titanium implants with internal hexagonal or conical connections under simulated oral loading conditions.
Materials And Methods: A total of 48 specimens were used.
Purpose: Evaluating the impact of the prosthetic material on implant- and prosthetic survival of implant-supported fixed complete dentures.
Study Selection: Electronic and hand searches were conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) to identify clinical studies including at least 10 patients restored with implant-supported dentures. The primary outcome was to evaluate the implant survival rate according to the applied restorative materials.
Objective: To investigate the long-term stability of a metal-free zirconia two-piece implant assembled with a carbon fiber-reinforced (CRF) screw by means of transformation propagation, potential changes in surface roughness, the gap size of the implant-abutment connection, and fracture load values.
Methods: In a combined procedure, two-piece implants made from alumina-toughened zirconia were dynamically loaded (10 cycles) and hydrothermally aged (85°, 60days). Implants made from titanium (Ti) and a titanium-zirconium (TiZr) alloy with a titanium abutment screw served as control.