Background: Botulinum toxin (BT) is a well-recognised treatment of chronic functional constipation (FC) and soiling refractory to medical treatment. The aims of this study were to assess the short and long-term outcomes of BT injection into the external anal sphincter muscles (EAS) for chronic FC treatment.
Methods: We studied 196 children unresponsive to medical management of chronic FC, soiling, painful defecation and withholding behaviour (Rome III criteria) from April 2011 to January 2023.
Aim We reviewed surgical outcomes for patients with colorectal cancer resections in Basildon and Thurrock University Hospital between April 2019 and March 2020. Methods Clinical characteristics of 141 patients who underwent surgical resection for colorectal cancer at the district hospital were assessed and reported, including tumor site, disease stage, and type of surgical resection performed. We reviewed 30- and 90-day postoperative mortality, postoperative complications, return to the theater, and extended hospital stay data for these patients.
View Article and Find Full Text PDFObjective: The aim of this work is to demonstrate the performance of the ECG noise extraction tool (ECGNExT) which provides estimates of ECG noise that are not significantly different from the inherent noise in an ECG generated by motion artifacts and other sources. In addition, this paper elaborates on use of ECGNExT in an algorithm evaluation context comparing two QRS detection algorithms.
Methods: 140 simultaneous pairs of clean ECGs and ECGs corrupted with motion-induced noise from 29 participants under five different and separate motion conditions were collected and analyzed.
Heart rate variability (HRV) features support several clinical applications, including sleep staging, and ballistocardiograms (BCGs) can be used to unobtrusively estimate these features. Electrocardiography is the traditional clinical standard for HRV estimation, but BCGs and electrocardiograms (ECGs) yield different estimates for heartbeat intervals (HBIs), leading to differences in calculated HRV parameters. This study examines the viability of using BCG-based HRV features for sleep staging by quantifying the impact of these timing differences on the resulting parameters of interest.
View Article and Find Full Text PDFThe time interval between the peaks in the electroccardiogram (ECG) and ballistocardiogram (BCG) waveforms, TEB, has been associated with the pre-ejection period (PEP), which is an important marker of ventricular contractility. However, the applicability of BCG-related markers in clinical practice is limited by the difficulty to obtain a replicable and consistent signal on patients. In this study, we test the feasibility of BCG measurements within a complex clinical setting, by means of an accelerometer under the head pillow of patients admitted to the Surgical Intensive Care Unit (SICU).
View Article and Find Full Text PDFEur Heart J Case Rep
November 2021
Background: Exercise stress testing (EST) identifies functional abnormalities that may manifest only during physiologic stress to the heart. This may have significant prognostic value in identifying latent conduction abnormalities in asymptomatic patients with myotonic dystrophy type 1 (MD1), who may benefit from prophylactic permanent pacemaker (PPM) implantation.
Case Report: We report the case of a patient with MD1 with a 5-month history of atypical left-sided chest pain.
Background: The goal of this work was to create a sharable dataset of heart-driven signals, including ballistocardiograms (BCGs) and time-aligned electrocardiograms (ECGs), photoplethysmograms (PPGs), and blood pressure waveforms.
Methods: A custom, bed-based ballistocardiographic system is described in detail. Affiliated cardiopulmonary signals are acquired using a GE Datex CardioCap 5 patient monitor (which collects ECG and PPG data) and a Finapres Medical Systems Finometer PRO (which provides continuous reconstructed brachial artery pressure waveforms and derived cardiovascular parameters).
Monitoring the sleep patterns of children with autism spectrum disorders (ASD) and understanding how sleep quality influences their daytime behavior is an important issue that has received very limited attention. Polysomnography (PSG) is commonly used as a gold standard for evaluating sleep quality in children and adults. However, the intrusive nature of sensors used as part of PSG can themselves affect sleep and is, therefore, not suitable for children with ASD.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2018
The link between daytime performance and sleep quality for severely disabled autistic children is not entirely understood. This paper presents nighttime data collected from a child with severe disabilities during a three-night pilot study conducted at Heartspring, Wichita, KS, using a bed-based system capable of unobtrusively tracking parameters for sleep quality assessment. The 'average sample correlation coefficient signal-to-noise ratio' is compared for ballistocardiograms acquired using four electromechanical film sensors versus four load cell sensors.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2018
An IEEE Engineering in Medicine and Biology Society (EMBS) student chapter can play an important service role for collegiate biomedical curricula, supporting (a) faculty and administrators as they offer biomedical programs and work to strengthen industry/community relationships, and (b) students as they engage in engineering skill development and seek industry employment, graduate school opportunities, or medical school placement. This paper summarizes recent projects and activities sponsored by the Kansas State University (KSU) Student Chapter of the IEEE EMBS - efforts intended to maintain interest in the student chapter while supporting its service role. Such a role will become more important in upcoming years in light of the increasing demand for biomedical engineers, especially in the Midwest United States, a reality which motivated the inception of a new KSU undergraduate degree in Biomedical Engineering starting in Fall 2018.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2018
Several methods are proposed in the literature to detect ballistocardiogram (BCG) peaks. There is a need to narrow these methods down in terms of their performance under similar conditions. This study reports early results from a systematic performance evaluation.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
August 2016
The relationship between sleep quality and daytime wellness and performance in severely disabled, autistic children is not well understood. While polysomnography and, more recently, actigraphy serve as means to obtain sleep assessment data from neurotypical children and adults, these techniques are not well-suited to severely autistic children. This paper presents recent progress on a bed sensor suite that can unobtrusively track physiological and behavioral parameters used to assess sleep quality.
View Article and Find Full Text PDFBackground: Individuals living with sickle cell disease (SCD) have significantly increased emergency department (ED) use compared to the general population. In Saudi Arabia, health care is free for all individuals and therefore has no bearing on increased ED visits. However, little is known about the relationship between quality of life (QoL) and frequency of acute care utilization in this patient population.
View Article and Find Full Text PDFHealth Qual Life Outcomes
November 2015
Background: There is a lack of research concerning health-related quality of life (HRQoL) in Saudi patients with sickle cell disease (SCD), particularly among adult populations. The aim of the current study was to describe the characteristics of SCD patients and their impact on their quality of life (QoL).
Methods: Six hundred twenty-nine adult SCD patients who attended King Fahad Hospital in Hofuf and King Fahad Central Hospital in Jazan were included in the analysis.
Background: The Al-Hassa area is one of the regions in Saudi Arabia where hemoglobinopathies are prevalent. The Saudi Ministry Of Heath designed a protocol for premarital testing after the royal decree in December 2003. The protocol was implemented in a February 2004 order.
View Article and Find Full Text PDF