The energy response of gross gamma dose rate monitors needs to be flat in order to prevent overestimation of dose at low gamma energies. In this paper, a discriminator threshold modulation based electronic energy compensation algorithm has been proposed for SiPM-scintillator based gamma detectors. Theoretical simulation studies were carried out in order to optimize the parameters of the periodic ramp voltage used for modulation of the discriminator threshold of a SiPM-GGAG:Ce,B based gamma dose rate monitor.
View Article and Find Full Text PDFThis research forms a part of the comprehensive Indian Environmental Radiation Monitoring Network program, focusing on the continuous measurement of absorbed dose rate in outdoor air due to natural gamma radiation (cosmic and terrestrial) in Bengaluru, Karnataka, India. Over the course of a decade (2013-2023), data were collected from 41 monitoring locations in the city using permanently field-installed Geiger-Mueller detector-based environmental radiation monitors. This paper presents an analysis of the extensive long-term monitoring results.
View Article and Find Full Text PDFThe Indian Environmental Radiation Monitoring Network continuously monitors the outdoor natural gamma absorbed dose rate in air at different locations throughout India by employing Geiger-Mueller (GM) detector-based field-installed environmental radiation monitors (ERMs). Hyderabad, Telangana, India is known to have high natural background radiation levels due to the presence of high concentrations of primordial radionuclides in its granitic rocks. There are a total of 59 ERMs installed at various locations across Hyderabad.
View Article and Find Full Text PDFIn this paper, the details of the development and performance characterisation of a compact, low-power gamma spectrometer for environmental gamma radiation monitoring networks are presented. To reduce the power consumption and the size of the spectrometer, a gamma detector comprising a silicon photomultiplier coupled to a Gd3Ga3Al2O12:Ce,B (GGAG:Ce,B) scintillator has been used for gamma spectrometry. Initially, a Monte Carlo simulation study was carried out to verify the suitability of the 5 mm × 5 mm × 5 mm GGAG:Ce,B crystal for spectrometry of gamma sources in the energy range 60-1332 keV.
View Article and Find Full Text PDFThe Indian Environmental Radiation Monitoring Network continuously monitors, throughout India, the absorbed dose rate in air due to outdoor natural gamma radiation, by using Geiger-Mueller detector-based standalone environmental radiation monitors. The network consists of 546 monitors spread across 91 monitoring locations distributed all over the country. In this paper, the countrywide long-term monitoring results are summarised.
View Article and Find Full Text PDFVegetables (Tomato - , green chilli - and bitter gourd - ) and fruits (Banana - , papaya - mosambi - from the cultivated areas around the Tummalapalle uranium mining site were analyzed for trace metals (Al, Cr, Mn, Fe, Ni, Cu, Zn, Pb, Be, V, Co, Cd and U) using inductively coupled plasma-mass spectrometer (ICP-MS). As per the estimated data, the concentrations of trace metals in vegetables and fruits are found in the range of 47.5-7.
View Article and Find Full Text PDF