Objective: To evaluate the effect of staining, glazing, and polishing of stabilized zirconia with 5 mol% of yttrium oxide (5Y-TZP) on the wear behavior of opposing tooth enamel.
Materials And Methods: The plane specimens of 5Y-TZP were divided into 6 groups (n = 10), according to surface treatment: as sintered, staining, glazing, polishing, staining followed by glazing, and staining followed by polishing, and positioned against tooth enamel during the two-body wear test (20 N, 2 Hz, until completing 300,000 cycles). The wear rates of tooth enamel were evaluated using a profile projector and a digital pachymeter as a measure of vertical height loss.
Objective: The purpose of this in vitro study was to evaluate the effect of staining, glazing, and polishing on the survival probability of monolithic crowns manufactured with preshaded stabilized zirconia with 5 mol% of yttrium oxide (5Y-TZP).
Materials And Methods: Monolithic crowns in the shape of an upper canine (1.5 mm of thickness) were manufactured by CAD/CAM, adhesively cemented on metallic foundation, and divided into 6 groups (n = 21): C (control), S (staining), G (glazing), P (polishing), SG (staining and glazing), and SP (staining and polishing).
The objective of this study was to evaluate microbial leakage by means of genome counts, through the implant-abutment interface in dental implants with different Morse taper abutments. Fifty-six samples were prepared and divided in four groups: CMC TB (14 Cylindrical Implants-14 TiBase Abutments), CMX TB (14 Conical Implants-14 TiBase Abutments), CMX PU (14 Conical Implants-14 Universal Abutment) and CMX U (14 Tapered Implants-14 UCLA Abutments). Assemblies had their interface submerged in saliva as the contaminant.
View Article and Find Full Text PDFJ Oral Implantol
February 2024
The aim of this study was to evaluate the mechanical behavior of UCLA and Mini-conical abutments for implants with Tri-channel connections regarding torque loss and vertical misfit. Twenty 3-element metal-ceramic fixed partial dentures (FPD) supported by 2 implants were manufactured and divided into 2 groups (n = 10): UCLA (group 1) and Mini-conical Abutments (group 2). The evaluation of torque loss was carried out before and after mechanical cycling, while the vertical fit was evaluated throughout the different stages of manufacturing the prostheses, as well pre- and postcycling (300,000 cycles, 30 N).
View Article and Find Full Text PDFObjectives: This study aims to identify the two-dimensional and three-dimensional analyses and evaluate the loss of tooth structure in the tooth's different constituent elements and the ceramic antagonist's surface.
Methods: In this study, three groups (n = 10) represented by different ceramic systems (lithium disilicate [GDis], lithium silicate reinforced with zirconia [GSil], and monolithic zirconia [GZir]) were evaluated. Each group obtained ten ceramic blocks and submitted them to the sintering/crystallization process.
Medicina (Kaunas)
July 2023
: The insertion of the dental implant in the bone is an essential step in prosthetic rehabilitation. The insertion torque has the potential to distort the prosthetic platform, which can cause future biomechanical problems with the continuous action of occlusal forces. The aim of this study is to evaluate different insertion torques in the deformation of tri-channel platform connections through two- and three-dimensional measurements with micro-CT.
View Article and Find Full Text PDFMaterials (Basel)
May 2023
The relationship between bacterial infiltration and internal conical Implant-Abutment Interfaces (IAIs) with different conicities still requires investigations that can offer valuable information in the clinical understanding of peri-implant health. The present study aimed to verify the bacterial infiltration of two internal conical connections with an angulation of 11.5° and 16° with the external hexagonal connection as a comparative after thermomechanical cycling using saliva as a contaminant.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
May 2023
This study compared the effect of using milled fiber-reinforced resin composite and Co-Cr (milled wax and lost-wax technique) frameworks for 4-unit implant-supported partial fixed dental prostheses; and also, evaluated the influence of the connector's cross-sectional geometries on the mechanical behavior. Three groups of milled fiber-reinforced resin composite (TRINIA) for 4-unit implant-supported frameworks (n = 10) with three connectors geometries (round, square, or trapezoid), and three groups of Co-Cr alloy frameworks manufactured by milled wax/lost wax and casting technique, were analyzed. The marginal adaptation was measured before cementation using an optical microscope.
View Article and Find Full Text PDFBackground and Objectives: There are limited data regarding the behavior of resin matrix ceramics for current CAD-CAM materials. Further studies may be beneficial and can help clinicians planning to use these materials during prosthodontic rehabilitation. The aim of this study was to evaluate and compare the flexural strength and strain distributions, filler content, wear, and reliability of two resin matrix ceramic CAD-CAM materials.
View Article and Find Full Text PDFCommercial Yttria-tetragonal zirconia polycrystalline (Y-TZP) was subjected to surface treatments, and the bond strength of dual resin cement to Y-TZP and failure modes were evaluated. Disks (12 mm × 2 mm), cylinders (7 mm × 3.3 mm), and bars (25 mm × 5 mm × 2 mm) were milled from Y-TZP CAD-CAM blocks, divided into seven groups, and subjected to different surface treatments; silicatization was used as control.
View Article and Find Full Text PDFPartially stabilized zirconia (5Y-PSZ) has been widely used to manufacture indirect monolithic restorations, and the effect of finishing procedures on the optical and mechanical properties of these materials are still unclear. The purpose of this study was to evaluate the effect of staining, polishing and glazing on surface roughness, crystalline phase content, microhardness, fracture toughness, dynamic elastic modulus, three-point flexural strength, strain distribution, color (∆E/∆L/∆a/∆b), and translucency before and after artificial accelerated aging (water spray and ultraviolet) of 5Y-PSZ. Bar-shaped and rectangle-shaped specimens of the 5Y-PSZ were prepared and divided into six groups, according to finishing procedure: GC (control), GS (staining), GG (glazing), GSG (staining and glazing), GP (polishing), GSP (staining and polishing).
View Article and Find Full Text PDFPurpose: Strains transferred to the supporting simulated bone structure by implant-supported full-arch fixed dental prostheses (FAFDPs) were analyzed by digital image correlation (DIC).
Materials And Methods: Polyurethane models were made using 3.75 × 11-mm implants and divided into the following groups with different implant numbers and design: EH5 (five implants/external hexagon), MT5 (five implants/internal taper), EH4 (four implants/external hexagon), and MT4 (four implants/internal taper).
This study evaluated the surface characteristics and bond strength of Y-TZP treated with Er:YAG laser at different focal distances. 120 Y-TZP blocks were divided into five groups (n=24), according to the surface treatment: no treatment (C-); sandblasting with silica-coated aluminum oxide particles (C+); and Er:YAG laser application at focal distances of 1mm (Er:YAG-1), 4mm (Er:YAG-4), and 7mm (Er:YAG-7). Surface characteristics were analyzed using Vickers microhardness, confocal laser microscope, scanning electron microscopy (SEM), and X-ray diffractometer (XRD).
View Article and Find Full Text PDFInt J Oral Maxillofac Implants
December 2019
Purpose: This study evaluates the micro shear bond strength of resin cement to an yttriastabilized zirconia ceramic and the survival probability of zirconia abutments and crowns after different surface treatments through a fatigue test.
Materials And Methods: The study was divided into two parts. For part 1, 95 zirconia disks were divided into five groups (n = 19): control, untreated, airborne particle abrasion with AlO particles before sintering, airborne particle abrasion with AlO particles after sintering, silicatization before sintering, and silicatization after sintering.
Objective: This study aimed to evaluate the fracture load and pattern of customized and non-customized zirconia abutments with Morse-taper connection.
Methods: 18 implants were divided into 3 groups according to the abutments used: Zr - with non-customized zirconia abutments; Zrc - with customized zirconia abutments; and Ti - with titanium abutments. To test their load capacity, a universal test machine with a 500-kgf load cell and a 0.
The use of zirconia abutments has increased because of aesthetics, but sometimes customization is necessary and its effect is unclear. This study evaluated the marginal fit and torque loss of customized and non-customized aesthetic zirconia abutments associated with Morse taper implants before and after thermomechanical cycling. Twenty-four implant/abutment/crown sets were divided into three groups (N = 8): Zr - non-customized zirconia abutments, Zrc - customized zirconia abutments, and Ti - titanium abutments.
View Article and Find Full Text PDFBackground: The biomechanical behavior of implant-supported titanium and zirconia full-arch fixed dental prosthesis (FAFDP) frameworks require further investigation.
Purpose: Strains transferred by implant-supported titanium (Ti) and zirconia (Zr) FAFDP frameworks were analyzed.
Materials And Methods: Maxillary 14-unit FAFDPs supported by 6 implants and 12-unit FAFDPs supported by 4 implants were tested.
Statement Of Problem: The loss of the first molar and second premolar could lead to mesial movement of the second molar, thus limiting the restoration space for the 2 missing teeth. Placement of a larger first molar is a common choice, but the best implant number and position option remain controversial.
Purpose: The purpose of this in vitro study was to test different planning options for replacing the mandibular first molar.
Dental ceramics have been widely used because of aesthetic, but wear is still questioned. There are relates that ceramic surface is prone to degradation by acidulated fluoride, that can increase wear rates. The aim of this study was to evaluate the effect of neutral and acidulated fluoride gel, used as preventive agents for professional use, at wear and compression strength of dental ceramics IPS e.
View Article and Find Full Text PDFThe present study evaluated the reliability of FEA on the results of different mechanical properties (E and v) of materials. Two 3D models of a maxillary canine with endodontic treatment, intracanal post, composite resin core and restored with porcelain-fused-to-metal crown were generated according to micro-CT images. Two groups with different E and ν values for porcelain, metal coping alloy, resin cement and composite resin were established.
View Article and Find Full Text PDFClin Oral Implants Res
April 2017
Objective: The aim of this study was to analyze failure modes and misfit of abutments with reduced diameter for both cement and screw retentions after cyclic loading.
Material And Methods: Forty morse-taper abutment/implant sets of titanium were divided into four groups (N = 10): G4.8S-4.
This study aimed to verify marginal fit and the effect of cement film thickness standardization on retention of provisional crowns made with prefabricated acrylic cylinders on abutments, using two temporary luting agents subjected or not to mechanical cycling. Provisional crowns were made from bis-acryl (Luxatemp Fluorescence) or methyl methacrylate (Duralay) resins on acrylic cylinders and marginal fit and cement film thickness were evaluated. For retention evaluation, crowns were cemented with two temporary luting agents: non-eugenol zinc oxide (Tempbond NE) or calcium hydroxide-based (Hydcal) cements and subjected to tensile strength in a universal testing machine.
View Article and Find Full Text PDFPurpose: It is still unclear whether four, six, or more implants should be used when restoring fully edentulous maxillae. This research evaluated the in vitro screw torque loss of zirconia frameworks supported by six implants and cantilevered zirconia frameworks supported by four implants.
Materials And Methods: Computer aided design/computer-assisted machining was used to fabricate 10 one-piece frameworks.
Objectives: This study evaluated the screw joint stability after cyclic loading of implant-supported titanium and zirconia CAD/CAM frameworks for fixed dental prostheses (FDPs) with different retention methods.
Material And Methods: Twenty four one-piece frameworks supported by six threaded implants placed in the maxilla were fabricated using a CAD/CAM technique (NeoShape). Dry-pressed porcelain crowns were luted to the frameworks to standardize the specimens.
Statement Of Problem: Few studies have investigated the microgap of long-span complete-arch fixed dental prosthesis zirconia frameworks.
Purpose: The purpose of this study was to evaluate the effects of cyclic loading on the vertical microgap of maxillary 12-unit prostheses supported by 4 implants and on 14-unit prostheses supported by 6 implants.
Material And Methods: One-piece zirconia frameworks were fabricated with a computer-aided design/computer-aided manufacturing technique and divided into 2 groups (n=5): a group of 12-unit prostheses and a group of 14-unit prostheses.