Publications by authors named "Adrian Chee"

As ultrasound-compatible flow phantoms are devised for performance testing and calibration, there is a practical need to obtain independent flow measurements for validation using a gold-standard technique such as particle image velocimetry (PIV). In this paper, we present the design of a new dual-modality flow phantom that allows ultrasound and PIV measurements to be simultaneously performed. Our phantom's tissue mimicking material is based on a novel hydrogel formula that uses propylene glycol to lower the freezing temperature of an ultrasound-compatible poly(vinyl) alcohol cryogel and, in turn, maintain the solution's optical transparency after thermocycling.

View Article and Find Full Text PDF

In the development of ultrasound localization microscopy (ULM) methods, appropriate test beds are needed to facilitate algorithmic performance calibration. Here, we present the design of a new ULM-compatible microvascular phantom with a forked, V-shaped wall-less flow channel pair ( 250 μ m channel width) that is bifurcated at a separation rate of 50 μ m/mm. The lumen core was fabricated using additive manufacturing, and it was molded within a polyvinyl alcohol (PVA) tissue-mimicking slab using the lost-core casting method.

View Article and Find Full Text PDF

For high-frame-rate ultrasound imaging, it remains challenging to implement on compact systems as a sparse imaging configuration with limited array channels. One key issue is that the resulting image quality is known to be mediocre not only because unfocused plane-wave excitations are used but also because grating lobes would emerge in sparse-array configurations. In this article, we present the design and use of a new channel recovery framework to infer full-array plane-wave channel datasets for periodically sparse arrays that operate with as few as one-quarter of the full-array aperture.

View Article and Find Full Text PDF

Vector flow imaging is a diagnostic ultrasound modality that is suited for the visualization of complex blood flow dynamics. One popular way of realizing vector flow imaging at high frame rates over 1000 fps is to apply multi-angle vector Doppler estimation principles in conjunction with plane wave pulse-echo sensing. However, this approach is susceptible to flow vector estimation errors attributed to Doppler aliasing, which is prone to arise when a low pulse repetition frequency (PRF) is inevitably used due to the need for finer velocity resolution or because of hardware constraints.

View Article and Find Full Text PDF

The Health Roundtable, a national benchmarking body, identified our institution as an outlier with a high number of postoperative venous thromboembolism (VTE) events. We performed a retrospective study to determine the accuracy of hospital coding for the incidence and severity of postoperative VTE. Of 232 patients identified from ICD-10 coding, 52 (22.

View Article and Find Full Text PDF

Background: Ultrasound vector flow imaging (VFI) shows potential as an emerging non-invasive modality for time-resolved flow mapping. However, its efficacy in tracking multidirectional pulsatile flow with temporal resolvability has not yet been systematically evaluated because of the lack of an appropriate test protocol.

Purpose: We present the first systematic performance investigation of VFI in tracking pulsatile flow in a meticulously designed scenario with time-varying, omnidirectional flow fields (with flow angles from 0° to 360°).

View Article and Find Full Text PDF

In atherosclerosis, low wall shear stress (WSS) is known to favor plaque development, while high WSS increases plaque rupture risk. To improve plaque diagnostics, WSS monitoring is crucial. Here, we propose wall shear imaging (WASHI), a noninvasive contrast-free framework that leverages high-frame-rate ultrasound (HiFRUS) to map the wall shear rate (WSR) that relates to WSS by the blood viscosity coefficient.

View Article and Find Full Text PDF

Obesity is a well-recognised risk factor for venous thromboembolism, and increased dosing of pharmacological prophylaxis is recommended in obese inpatients. We performed a clinical decision support intervention by adjusting order sentences of prophylactic enoxaparin within our electronic medical records, which significantly improved appropriate dosing for thromboprophylaxis in obese inpatients at our institution.

View Article and Find Full Text PDF

High-frame-rate ultrasound imaging uses unfocused transmissions to insonify an entire imaging view for each transmit event, thereby enabling frame rates over 1000 frames per second (fps). At these high frame rates, it is naturally challenging to realize real-time transfer of channel-domain raw data from the transducer to the system back end. Our work seeks to halve the total data transfer rate by uniformly decimating the receive channel count by 50% and, in turn, doubling the array pitch.

View Article and Find Full Text PDF

Spiral array transducers with a sparse 2-D aperture have demonstrated their potential in realizing 3-D ultrasound imaging with reduced data rates. Nevertheless, their feasibility in high-volume-rate imaging based on unfocused transmissions has yet to be established. From a metrology standpoint, it is essential to characterize the acoustic field of unfocused transmissions from spiral arrays not only to assess their safety but also to identify the root cause of imaging irregularities due to the array's sparse aperture.

View Article and Find Full Text PDF

Conventional ultrasound with frequency (2-15 MHz) has been a global diagnostic and therapeutic tool in clinical medicine, and high-frequency ultrasound (>30 MHz) has been a powerful investigative device for preclinical studies such as cardiovascular research. In this chapter, we describe the use of conventional ultrasound with a 2.5-10 MHz transducer as an investigative device for the measurement/detection of blood flow in rabbit model.

View Article and Find Full Text PDF

Iatrogenic ureteral injury, as a commonly encountered problem in gynecologic, colorectal, and pelvic surgeries, is known to be difficult to detect in situ and in real-time. Consequently, this injury may be left untreated, thereby leading to serious complications such as infections, renal failure, or even death. Here, high-performance tubular porous pressure sensors were proposed to identify the ureter in situ intraoperatively.

View Article and Find Full Text PDF

The medical physics community has hitherto lacked an effective calibration phantom to holistically evaluate the performance of three-dimensional (3D) flow imaging techniques. Here, we present the design of a new omnidirectional, three-component (3-C) flow phantom whose lumen is consisted of a helical toroid structure (4 mm lumen diameter; helically winded for 5 revolutions over a torus with 10 mm radius; 5 mm helix radius). This phantom's intraluminal flow trajectory embraces all combinations of x, y, and z directional components, as confirmed using computational fluid dynamics (CFD) simulations.

View Article and Find Full Text PDF

Despite being used clinically as a noninvasive flow visualization tool, color flow imaging (CFI) is known to be prone to aliasing artifacts that arise due to fast blood flow beyond the detectable limit. From a visualization standpoint, these aliasing artifacts obscure proper interpretation of flow patterns in the image view. Current solutions for resolving aliasing artifacts are typically not robust against issues such as double aliasing.

View Article and Find Full Text PDF

Objective: To devise a new urodynamic imaging framework that can provide time-resolved visualization of urinary flow and urethral deformation during the initiation phase of voiding.

Materials And Methods: Contrast-enhanced urodynamic vector projectile imaging (CE-UroVPI) was devised using the principles of high-frame rate ultrasound, microbubble contrast agents, and flow vector mapping. CE-UroVPI was implemented using a research-purpose ultrasound scanner (5 MHz frequency) and commercial contrast agents (USphere Prime).

View Article and Find Full Text PDF

Purpose: Complex blood flow is commonly observed in the carotid bifurcation, although the factors that regulate these patterns beyond arterial geometry are unknown. The emergence of high-frame-rate ultrasound vector flow imaging allows for noninvasive, time-resolved analysis of complex hemodynamic behavior in humans, and it can potentially help researchers understand which physiological stressors can alter carotid bifurcation hemodynamics in vivo. Here, we seek to pursue the first use of vector projectile imaging (VPI), a dynamic form of vector flow imaging, to analyze the regulation of carotid bifurcation hemodynamics during experimental reductions in cardiac output induced via a physiological stressor called lower body negative pressure (LBNP).

View Article and Find Full Text PDF

Purpose: Assessment of urethral dynamics is clinically regarded to be important in analyzing the functional impact of pathological features like urethral obstruction, albeit it is difficult to perform directly in vivo. To facilitate such an assessment, urethra phantoms may serve well as investigative tools by reconstructing urethral dynamics based on anthropomorphic factors. Here, our aim is to design a new class of anatomically realistic, deformable urethra phantoms that can simulate the geometric, mechanical, and hydrodynamic characteristics of the male prostatic urethra.

View Article and Find Full Text PDF

Purpose: Flow instability has been shown to contribute to the risk of future cardiovascular and cerebrovascular events. Nonetheless, it is challenging to noninvasively detect and identify flow instability in blood vessels. Here, we present a new framework called Doppler ultrasound bandwidth imaging (DUBI) that uses high-frame-rate ultrasound and Doppler bandwidth analysis principles to assess flow instability within an image view.

View Article and Find Full Text PDF

The eigen-based filter has theoretically established itself as a potent solution in ultrasound color flow imaging (CFI) for combating against clutter arising from moving tissues. Yet, it remains poorly understood on how much gain in flow detection sensitivity and specificity can be delivered by this adaptive clutter filter. Here, we investigated the receiver operating characteristic (ROC) of the eigen-based clutter filter to statistically evaluate its efficacy.

View Article and Find Full Text PDF

Regional wall stiffening and thickening are two common pathological features of arteries. To account for these two features, we developed a new arterial phantom design framework to facilitate the development of vessel models that contain a lesion segment whose wall stiffness and thickness differ from those of other segments. This new framework is based on multi-part injection molding principles that sequentially casted the lesion segment and the flank segments of the vessel model using molding parts devised with computer-aided design tools.

View Article and Find Full Text PDF

Flow phantoms with anatomically realistic geometry and high acoustic compatibility are valuable investigative tools in vascular ultrasound studies. Here, we present a new framework to fabricate ultrasound-compatible flow phantoms to replicate human vasculature that is tortuous, nonplanar, and branching in nature. This framework is based upon the integration of rapid prototyping and investment casting principles.

View Article and Find Full Text PDF