Background/aims: Functional lumen imaging probe (FLIP) Panometry has demonstrated utility in the assessment of esophageal motility as a complement to existing methodologies like high-resolution manometry. However, as FLIP is typically performed with sedation during routine endoscopy, there is potential for impact of sedation agents on esophageal motility. We aim to examine the effects of conscious sedation with midazolam and fentanyl on FLIP Panometry metrics and classification.
View Article and Find Full Text PDFNeurogastroenterol Motil
February 2023
Introduction: Functional luminal imaging probe (FLIP) Panometry evaluates the esophageal response to distension involving biomechanics and motility. We have observed that hiatus hernia (HH) is evident during FLIP studies as a separation between the crural diaphragm (CD) and lower esophageal sphincter (LES) like what is seen with high-resolution manometry (HRM). The aim of this study was to compare FLIP findings to endoscopy and HRM in the detection of HH.