The potential use of fiber-reinforced based polycarbonate-urethanes (PCUs) as candidate meniscal substitutes was investigated in this study. Mechanical test pieces were designed and fabricated using a compression molding technique. Ultra-High Molecular Weight Polyethylene (UHMWPE) fibers were impregnated into PCU matrices, and their mechanical and microstructural properties evaluated.
View Article and Find Full Text PDFThe meniscus is a complex and frequently damaged tissue which requires a substitute capable of reproducing similar biomechanical functions. This study aims to develop a synthetic meniscal substitute that can mimic the function of the native meniscus. Medical grade silicones reinforced with nylon were fabricated using compression moulding and evaluated for mechanical and tribological properties.