Next-generation virtual/augmented reality (VR/AR) headsets may rival the desktop computer systems that are approved for clinical interpretation of radiologic images, but require validation for high-resolution low-luminance diagnoses like diverticulitis. The primary aim of this study is to compare diagnostic performance for detecting diverticulitis on CT between radiologists using a headset versus a desktop. The secondary aim is to survey participating radiologists about the usage of both devices.
View Article and Find Full Text PDFPurpose: To test the ability of inversion-recovery ultrashort echo time (IR-UTE) MRI to directly detect demyelination in mice using a standard cuprizone mouse model.
Methods: Non-aqueous myelin protons have ultrashort Ts and are "invisible" with conventional MRI sequences but can be detected with UTE sequences. The IR-UTE sequence uses an adiabatic inversion-recovery preparation to suppress the long T water signal so that the remaining signal is from the ultrashort T myelin component.
Background: The effect of dehydration of cartilage samples and rehydration with native synovial fluid or normal saline on quantitative ultrashort echo time (UTE) biomarkers are unknown. We aimed to investigate the effect of cartilage dehydration-rehydration on UTE biomarkers and to compare the rehydration capabilities of native synovial fluid and normal saline.
Methods: A total of 37 cartilage samples were harvested from patients (n=5) who underwent total knee replacement.
In the original publication, there was a mistake in Figure 1 as published [...
View Article and Find Full Text PDFA relationship between an acidic pH in the joints, osteoarthritis (OA), and pain has been previously demonstrated. Acidosis Chemical Exchange Saturation Transfer (acidoCEST) indirectly measures the extracellular pH through the assessment of the exchange of protons between amide groups on iodinated contrast agents and bulk water. It is possible to estimate the extracellular pH in the osteoarthritic joint using acidoCEST MRI.
View Article and Find Full Text PDFThe objective of the current study was to investigate the feasibility of quantitative 3D ultrashort echo time (UTE)-based biomarkers in detecting proteoglycan (PG) loss and collagen degradation in human cartilage. A total of 104 cartilage samples were harvested for a trypsin digestion study (n = 44), and a sequential trypsin and collagenase digestion study (n = 60), respectively. Forty-four cartilage samples were randomly divided into a trypsin digestion group (tryp group) and a control group (phosphate-buffered saline [PBS] group) (n = 22 for each group) for the trypsin digestion experiment.
View Article and Find Full Text PDFTaspase1, a highly conserved threonine protease encoded by TASP1, cleaves nuclear histone-modifying factors and basal transcription regulators to orchestrate diverse transcription programs. Hereditary loss-of-function mutation of TASP1 has recently been reported in humans as resulting in an anomaly complex syndrome, which manifests with hematological, facial, and skeletal abnormalities. Here, we demonstrate that Taspase1-mediated cleavage of TFIIAα-β, rather than of MLL1 or MLL2, in mouse embryos was required for proper fetal liver hematopoiesis and correct segmental identities of the axial skeleton.
View Article and Find Full Text PDFHepatic incidental findings often are seen on cross-sectional imaging examinations of the chest, spine, pelvis, or other nondedicated hepatic imaging. Radiologists are tasked with appropriately triaging, which requires further evaluation, even in the setting of an otherwise limited evaluation. This article reviews common benign entities encountered on ultrasound, computed tomography, or magnetic resonance imaging, along with their characteristic imaging features.
View Article and Find Full Text PDFDirect myelin imaging is promising for characterization of multiple sclerosis (MS) brains at diagnosis and in response to therapy. In this study, a 3D inversion recovery-prepared ultrashort echo time cones (IR-UTE-Cones) sequence was used for both morphological and quantitative imaging of myelin on a clinical 3 T scanner. Myelin powder phantoms with different myelin concentrations were imaged with the 3D UTE-Cones sequence and it showed a strong correlation between concentrations and UTE-Cones signals, demonstrating the ability of the UTE-Cones sequence to directly image myelin in the brain.
View Article and Find Full Text PDFThe purpose of this study is to investigate the effect of extending the spiral sampling window on quantitative 3D ultrashort echo time (UTE) Cones imaging of major knee joint tissues including articular cartilage, menisci, tendons and ligaments at 3 T. Nine cadaveric human whole knee specimens were imaged on a 3 T clinical MRI scanner. A series of quantitative 3D UTE Cones imaging biomarkers including T *, T , adiabatic T , magnetization transfer ratio (MTR) and macromolecular fraction (MMF) were estimated using spiral sampling trajectories with various durations.
View Article and Find Full Text PDFBackground: Myelin alteration is closely associated with neurological diseases such as multiple sclerosis (MS). Unfortunately, due to myelin's extremely short T2* (~0.3 ms or shorter at 3T), it cannot be directly imaged with conventional MR imaging techniques.
View Article and Find Full Text PDFBackground Signal contamination from long T2 water is a major challenge in direct imaging of myelin with MRI. Nulling of the unwanted long T2 signals can be achieved with an inversion recovery (IR) preparation pulse to null long T2 white matter within the brain. The remaining ultrashort T2 signal from myelin can be detected with an ultrashort echo time (UTE) sequence.
View Article and Find Full Text PDFPurpose: Quantitative imaging methods could improve diagnosis of rotator cuff degeneration, but the capability of quantitative MR and US imaging parameters to detect alterations in collagen is unknown. The goal of this study was to assess quantitative MR and US imaging measures for detecting abnormalities in collagen using an in vitro model of tendinosis with biochemical and histological correlation.
Method: 36 pieces of supraspinatus tendons from 6 cadaveric donors were equally distributed into 3 groups (2 subjected to different concentrations of collagenase and a control group).
Purpose: Direct myelin imaging can improve the characterization of myelin-related diseases such as multiple sclerosis. In this study, we explore a novel method to directly image myelin using inversion recovery-prepared hybrid encoding (IR-HE) UTE MRI.
Methods: The IR-HE sequence uses an adiabatic inversion pulse to suppress the long T white matter signal, followed by 3D dual-echo HE utilizing both single point imaging and radial frequency encoding, for which the subtraction image between 2 echoes reveals the myelin signal with high contrast.
Cortical bone assessment using magnetic resonance imaging (MRI) has recently received great attention in an effort to avoid the potential harm associated with ionizing radiation-based techniques. Ultrashort echo time MRI (UTE-MRI) techniques can acquire signal from major hydrogen proton pools in cortical bone, including bound and pore water, as well as from the collagen matrix. This study aimed to develop and evaluate the feasibility of a technique for mapping bound water, pore water, and collagen proton densities in human cortical bone ex vivo and in vivo using three-dimensional UTE Cones (3D-UTE-Cones) MRI.
View Article and Find Full Text PDFUltrashort echo time magnetic resonance imaging (UTE-MRI) techniques have been increasingly used to assess cortical bone microstructure. High resolution micro computed tomography (μCT) is routinely employed for validating the MRI-based assessments. However, water protons in cortical bone may reside in micropores smaller than the detectable size ranges by μCT.
View Article and Find Full Text PDFPurpose: To investigate the effect of stretching sampling window on quantitative 3D ultrashort TE (UTE) imaging of cortical bone at 3 T.
Methods: Ten bovine cortical bone and 17 human tibial midshaft samples were imaged with a 3T clinical MRI scanner using an 8-channel knee coil. Quantitative 3D UTE imaging biomarkers, including T , , magnetization transfer ratio and magnetization transfer modeling, were performed using radial or spiral Cones sampling trajectories with various durations.
Intracortical bone porosity is a key microstructural parameter that determines bone mechanical properties. While clinical MRI visualizes the cortical bone with a signal void, ultrashort echo time (UTE) MRI can acquire high signal from cortical bone, thus enabling quantitative assessments. Magnetization transfer (MT) imaging combined with UTE-MRI can indirectly assess protons in the bone collagenous matrix, which are inversely related to porosity.
View Article and Find Full Text PDFPurpose: To measure T relaxations for the major tissues in whole knee joints on a clinical 3T scanner.
Methods: The 3D UTE-Cones actual flip angle imaging (AFI) method was used to map the transmission radiofrequency field (B ) in both short and long T tissues, which was then used to correct the 3D UTE-Cones variable flip angle (VFA) fitting to generate accurate T maps. Numerical simulation was carried out to investigate the accuracy of T measurement for a range of T values, excitation pulse durations, and B errors.
Purpose: In this study, we explore the feasibility of a new imaging scheme for quantitative susceptibility mapping (QSM): continuous single-point imaging (CSPI), which uses a pure phase encoding strategy to achieve true phase imaging and improve QSM accuracy.
Methods: The proposed CSPI is a modification of conventional SPI to allow acquisition of multiple echoes in a single scan. Immediately following a phase encoding gradient, the free induction decay is continuously sampled with extremely high temporal resolution to obtain k-space data at a fixed spatial frequency (i.
Purpose: To develop a 3D adiabatic T prepared ultrashort echo time cones (3D AdiabT UTE-Cones) sequence for whole knee imaging on a clinical 3T scanner.
Methods: A train of adiabatic full passage pulses were used for spin locking, followed by time-efficient multispoke UTE acquisition to detect signals from both short and long T tissues in the whole knee joint. A modified signal model was proposed for multispoke UTE data fitting.
Purpose: To evaluate the echo dependence of 3D ultrashort echo time (TE) quantitative susceptibility mapping (3D UTE-QSM) and effective transverse relaxation rate ( R2*) measurement in the setting of high concentrations of iron oxide nanoparticles.
Methods: A phantom study with iron concentrations ranging from 2 to 22 mM was performed using a 3D UTE Cones sequence. Simultaneous QSM processing with morphology-enabled dipole inversion (MEDI) and R2* single exponential fitting was conducted offline with the acquired 3D UTE data.
Purpose: UTE sequences with a minimal nominal TE of 8 µs have shown promise for direct imaging of myelin protons (T , < 1 ms). However, there is still debate about the efficiency of 2D slice-selective UTE sequences in exciting myelin protons because the half excitation pulses used in these sequences have a relatively long duration (e.g.
View Article and Find Full Text PDFObjective: Despite patients' increasing interest in reading their own imaging results, little is known about how patients interpret the reporting terminology of radiologists. The purpose of this study was to survey patients and radiologists to improve understanding of how each group views commonly used phrases within the radiology report.
Subjects And Methods: Patients and radiologists were asked to assign a numerical likelihood of the presence of metastatic disease based on their understanding of radiology report phrasing.
Unlabelled: The Cancer Genome Atlas project identified HER2 somatic mutations and gene amplification in 7% of patients with colorectal cancer. Introduction of the HER2 mutations S310F, L755S, V777L, V842I, and L866M into colon epithelial cells increased signaling pathways and anchorage-independent cell growth, indicating that they are activating mutations. Introduction of these HER2 activating mutations into colorectal cancer cell lines produced resistance to cetuximab and panitumumab by sustaining MAPK phosphorylation.
View Article and Find Full Text PDF