Purpose: The development of advanced digital orthognathic surgical protocols requires investigation to determine the accuracy of surgical outcomes. This report's purpose is to quantify 3-dimensional linear discrepancies between simulated and actual results for double-jaw orthognathic surgery utilizing occlusally-based guides in conjunction with patient-specific fixation in both jaws.
Methods: This retrospective cohort study assessed the accuracy of double-jaw orthognathic surgery, in all cases performed by 1 surgeon between May 2019 and January 2021, utilizing occlusally-based guides and patient-specific fixation plates in both maxillary and mandibular surgeries.
Standard treatment of mandibular nonunion includes debridement and application of maxillomandibular or rigid internal fixation techniques, with adjunctive bone grafting when necessary. Frequently described in the orthopaedic literature, low-intensity pulsed ultrasound therapy (LIPUS) is a noninvasive treatment modality used to accelerate healing of fresh fractures and established nonunions. The purpose of this study was to conduct a systematic review to determine the extent of LIPUS study in the treatment of mandibular nonunions to identify whether LIPUS represents an effective nonsurgical alternative or adjunct for nonunion management.