Purpose: To develop a method based on identification of the widest region of the surgical limbus that can yield quick and accurate orientation of excised human donor corneas.
Methods: Corneoscleral tissue from donors 49 to 75 years old was marked at the temporal sclera at the time of recovery. Digital images obtained from 20 corneas stored in viewing chambers, retroilluminated and viewed from the endothelial side, were used to quantify the per-degree radial width of the surgical limbus, defined as the distance from the scleral spur to clear cornea.