Publications by authors named "Adam Farag"

Tumor hypoxia is a negative prognostic factor in many tumors and is predictive of metastatic spread and poor responsiveness to both chemotherapy and radiotherapy. To assess the feasibility of using F-Fluoroazomycin arabinoside (FAZA) PET/MR to image tumor hypoxia in patients with locally advanced rectal cancer (LARC) prior to and following neoadjuvant chemoradiotherapy (nCRT). The secondary objective was to compare different reference tissues and thresholds for tumor hypoxia quantification.

View Article and Find Full Text PDF

Purpose: The aims of this study were to perform a comprehensive review and meta-analyses and to report pooled diagnostic results on CXCR4-targeted PET, particularly considering detection, visualization, and prognostication.

Patients And Methods: This study followed PRISMA-DTA. A systematic search was conducted on major medical literature databases up to March 1, 2024.

View Article and Find Full Text PDF

We aimed to determine if clinical parameters and radiomics combined with sarcopenia status derived from baseline F-FDG-PET/CT could predict developing metastatic disease and overall survival (OS) in gastroesophageal cancer (GEC). Patients referred for primary staging who underwent F-FDG-PET/CT from 2008 to 2019 were evaluated retrospectively. Overall, 243 GEC patients (mean age = 64) were enrolled.

View Article and Find Full Text PDF

Positron emission tomography/magnetic resonance (PET/MR) imaging has gone through major hardware improvements in recent years, making it a reliable state-of-the-art hybrid modality in clinical practice. At the same time, image reconstruction, attenuation correction, and motion correction algorithms have significantly evolved to provide high-quality images. Part I of the current review discusses technical basics, pre-clinical applications, and clinical applications of PET/MR in radiation oncology and head and neck imaging.

View Article and Find Full Text PDF

To assess the impact of the COVID-19 pandemic on the diagnosis, staging and outcome of a selected population throughout the first two years of the pandemic, we evaluated oncology patients undergoing PET/CT at our institution. A retrospective population of lung cancer, melanoma, lymphoma and head and neck cancer patients staged using PET/CT during the first 6 months of the years 2019, 2020 and 2021 were included for analysis. The year in which the PET was performed was our exposure variable, and our two main outcomes were stage at the time of the PET/CT and overall survival (OS).

View Article and Find Full Text PDF

. Recently, approaches have utilized the superior anatomical information provided by magnetic resonance imaging (MRI) to guide the reconstruction of positron emission tomography (PET). One of those approaches is the Bowsher's prior, which has been accelerated lately with a convolutional neural network (CNN) to reconstruct MR-guided PET in the imaging domain in routine clinical imaging.

View Article and Find Full Text PDF

Objectives: To calculate the pooled diagnostic performances of whole-body [F]FDG PET/MR in M staging of [F]FDG-avid cancer entities.

Methods: A diagnostic meta-analysis was conducted on the [F]FDG PET/MR in M staging, including studies: (1) evaluated [F]FDG PET/MR in detecting distant metastasis; (2) compared[ F]FDG PET/MR with histopathology, follow-up, or asynchronous multimodality imaging as the reference standard; (3) provided data for the whole-body evaluation; (4) provided adequate data to calculate the meta-analytic performances. Pooled performances were calculated with their confidence interval.

View Article and Find Full Text PDF

Background: Cardiac and respiratory motions in clinical positron emission tomography (PET) are a major contributor to inaccurate PET quantification and lesion characterisation. In this study, an elastic motion-correction (eMOCO) technique based on mass preservation optical flow is adapted and investigated for positron emission tomography-magnetic resonance imaging (PET-MRI) applications.

Methods: The eMOCO technique was investigated in a motion management QA phantom and in twenty-four patients who underwent PET-MRI for dedicated liver imaging and nine patients for cardiac PET-MRI evaluation.

View Article and Find Full Text PDF

Background: Accurate quantification of radioactivity, measured by an integrated positron emission tomography (PET) and magnetic resonance imaging (MRI) system, is still a challenge. One aspect of such a challenge is to correct for the hardware attenuation, such as the patient table and radio frequency (RF) resonators. For PET/MRI systems, computed tomography (CT) is commonly used to produce hardware attenuation correction (AC) maps, by converting Hounsfield units (HU) to a linear attenuation coefficients (LAC) map at the PET energy level 511 keV, using a bilinear model.

View Article and Find Full Text PDF

Background: Simultaneous cardiovascular imaging with positron emission tomography (PET) and magnetic resonance imaging (MRI) requires tools such as radio frequency (RF) phased arrays to achieve high temporal and spatial resolution in the MRI, as well as accurate quantification of PET. Today, high-density phased arrays (> 16 channels) used for cardiovascular PET/MRI are not designed to achieve low PET attenuation, and correcting the PET attenuation they cause requires off-line reconstruction, extra time and resources.

Purpose: Motivated by previous work assessing the MRI performance of a novel prospectively designed 32-channel phased array, this study assessed the PET image quality with this array in place.

View Article and Find Full Text PDF

Background: Cardiovascular imaging using hybrid positron emission tomography (PET) and magnetic resonance imaging (MRI) requires a radio frequency phased array resonator capable of high acceleration factors in order to achieve the shortest breath-holds while maintaining optimal MRI signal-to-noise ratio (SNR) and minimum PET photon attenuation. To our knowledge, the only two arrays used today for hybrid PET/MRI cardiovascular imaging are either incapable of achieving high acceleration or affect the PET photon count greatly.

Purpose: This study is focused on the evaluation of the MRI performance of a novel third-party prototype 32-channel phased array designed for simultaneous PET/MRI cardiovascular imaging.

View Article and Find Full Text PDF

Background: Overtreatment of prostate cancer (PCa) is a healthcare issue. Development of noninvasive imaging tools for improved characterization of prostate lesions might reduce overtreatment.

Purpose: To measure the distribution of tissue sodium concentration (TSC), proton T -weighted signal, and apparent diffusion coefficient (ADC) values in human PCa and to test the presence of a correlation between regional differences in imaging metrics and the Gleason grade of lesions determined from histopathology.

View Article and Find Full Text PDF

Background: To develop and optimize radiofrequency (RF) hardware for the detection of endogenous sodium ((23) Na) by 3.0 Tesla (T) MRI in the human prostate.

Methods: A transmit-only receive-only (TORO) RF system of resonators consisting of an unshielded, asymmetric, quadrature birdcage (transmit), and an endorectal (ER), linear, surface (receive) coil were developed and tested on a 3T MRI scanner.

View Article and Find Full Text PDF

Purpose: The goal of this work was to investigate lung morphological changes associated with chronic obstructive pulmonary disease (COPD) using hyperpolarized (129) Xe diffusion-weighted MRI.

Methods: Hyperpolarized (129) Xe MRI was performed at three different nonzero diffusion sensitizations (b-value = 12, 20, and 30 s/cm(2) ) in the lungs of four subjects with COPD and four healthy volunteers. The image signal intensities were fit as a function of b-value to obtain anisotropic diffusion coefficient maps for all subjects.

View Article and Find Full Text PDF

Purpose: To quantitatively compare hyperpolarized helium 3 (3He) and xenon 129 (129Xe) magnetic resonance (MR) images obtained within 5 minutes in healthy volunteers and patients with chronic obstructive pulmonary disease (COPD) and to evaluate the correlations between 3He and 129Xe MR imaging measurements and those from spirometry and plethysmography.

Materials And Methods: This study was approved by an ethics board and compliant with HIPAA. Written informed consent was obtained from all subjects.

View Article and Find Full Text PDF

Rationale And Objectives: The objective of this study was to evaluate the tolerability of hyperpolarized (129)Xe gas inhaled from functional residual capacity and magnetic resonance imaging in healthy subjects and those with pulmonary disease.

Materials And Methods: Twelve healthy volunteers (mean age, 59 ± 17 years), seven subjects with asthma (mean age, 47 ± 7 years), 10 subjects with chronic obstructive pulmonary disease (mean age, 74 ± 4 years), three subjects with cystic fibrosis (mean age, 27 ± 10 years), and a single subject with radiation-induced lung injury (age, 66 years) were enrolled and evaluated over 43 visits with 136 anoxic inhalations of 500 mL (129)Xe gas mixed with 500 mL (4)He gas. Oxygen saturation and heart rate were monitored during the breath-hold and imaging; subjects were queried for adverse events (AEs) before and immediately following gas inhalation and for 24 hours after the last dose.

View Article and Find Full Text PDF