Publications by authors named "Adam Cyr"

Unlabelled: Breast implants improve quality of life in patients seeking improved breast aesthetics, and are known to minimize human injury in the less common scenario of penetrating trauma. People commonly sustain rib and sternum fractures and thoracic injury in motor vehicle crashes (MVC), a form of blunt traumatic injury. Whether breast implants minimize injury during MVC is unknown.

View Article and Find Full Text PDF

Knee articular geometry and surface morphology greatly affect knee joint mechanics. Intra-subject variations in bone morphology and the passive range of motion have been well documented in the literature; however, the relationship between these two characteristics is not well understood. The objective of this study was to describe the correlation between knee joint anatomical features and passive range of motion using a statistical model.

View Article and Find Full Text PDF

This ballistics study examines whether saline breast implants can decrease tissue penetration in firearm injuries. We hypothesize that the fluid column within a saline breast implant can alter bullet velocity and/or bullet pattern of mushrooming. The two experimental groups included saline implants with 7.

View Article and Find Full Text PDF

Purpose: Quantification of knee motion is essential for assessment of pathologic joint function, such as tracking osteoarthritis progression and evaluating outcomes after conservative or surgical treatment, including total knee arthroplasty. Our purpose was to establish a useful baseline for the kinematic envelope of knee motion in healthy older adults performing movements of daily living.

Methods: A high-speed stereo radiography system was used to measure the three-dimensional tibiofemoral kinematics of eight healthy people over 55 yr of age (4 women/4 men; age, 61.

View Article and Find Full Text PDF

Complications in the patellofemoral (PF) joint of patients with total knee replacements include patellar subluxation and dislocation, and remain a cause for revision. Kinematic measurements to assess these complications and evaluate implant designs require the accuracy of dynamic stereo-radiographic systems with 3D-2D registration techniques. While tibiofemoral kinematics are typically derived by tracking metallic implants, PF kinematic measurements are difficult as the patellar implant is radiotransparent and a representation of the resected patella bone requires either pre-surgical imaging and precise implant placement or post-surgical imaging.

View Article and Find Full Text PDF

Modeling complex knee biomechanics is a continual challenge, which has resulted in many models of varying levels of quality, complexity, and validation. Beyond modeling healthy knees, accurately mimicking pathologic knee mechanics, such as after cruciate rupture or meniscectomy, is difficult. Experimental tests of knee laxity can provide important information about ligament engagement and overall contributions to knee stability for development of subject-specific models to accurately simulate knee motion and loading.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates how changes in the strength and activation of hamstrings affect knee joint movement after injuries or surgeries.
  • It examines knee kinematics on eight cadaver knees under different hamstring loading configurations, focusing on the effects of varying the force ratio between the semimembranosus and biceps femoris muscles.
  • Results show that altering the distribution of hamstring forces influences knee movement patterns, highlighting the importance of medial-lateral hamstring balance for knee function.
View Article and Find Full Text PDF

Healthy patellofemoral (PF) joint mechanics are critical to optimal function of the knee joint. Patellar maltracking may lead to large joint reaction loads and high stresses on the articular cartilage, increasing the risk of cartilage wear and the onset of osteoarthritis. While the mechanical sources of PF joint dysfunction are not well understood, links have been established between PF tracking and abnormal kinematics of the tibiofemoral (TF) joint, specifically following cruciate ligament injury and repair.

View Article and Find Full Text PDF

The mechanics of the knee are complex and dependent on the shape of the articular surfaces and their relative alignment. Insight into how anatomy relates to kinematics can establish biomechanical norms, support the diagnosis and treatment of various pathologies (e.g.

View Article and Find Full Text PDF
Article Synopsis
  • Understanding the soft-tissue contribution to total joint constraint (TJC) is crucial for predicting joint movement and improving surgical techniques.
  • Previous research has mainly focused on the strain and tension of collateral ligaments under specific conditions, leaving a gap in understanding their role across a wider range of loads and motion.
  • This study used pressure sensors in cadaver knees to measure the contributions of medial and lateral collateral ligaments at various flexion angles and external loads, finding that the MCL and LCL play significant roles in joint stability under different conditions, which can inform recovery from injuries and surgical approaches.
View Article and Find Full Text PDF

The net laxity of the knee is a product of individual ligament structures that provide constraint for multiple degrees of freedom (DOF). Clinical laxity assessments are commonly performed along a single axis of motion, and lack analyses of primary and coupled motions in terms of translations and rotations of the knee. Radial basis functions (RBFs) allow multiple DOF to be incorporated into a single method that accounts for all DOF equally.

View Article and Find Full Text PDF

The interrelationship that exists between multiple degrees of freedom to produce a net constraint across the range of passive motion of the knee is not fully understood. Manual joint laxity assessments were performed on 28 cadaveric specimens and used to develop a unified description of the passive laxity envelope that incorporated multiple degrees of freedom into a single analysis using radial basis functions. The unified envelopes were then included in a principal component analysis to identify the primary modes of variation.

View Article and Find Full Text PDF

Kneeling is required during daily living for many patients after total knee replacement (TKR), yet many patients have reported that they cannot kneel due to pain, or avoid kneeling due to discomfort, which critically impacts quality of life and perceived success of the TKR procedure. The objective of this study was to evaluate the effect of component design on patellofemoral (PF) mechanics during a kneeling activity. A computational model to predict natural and implanted PF kinematics and bone strains after kneeling was developed and kinematics were validated with experimental cadaveric studies.

View Article and Find Full Text PDF
Article Synopsis
  • Posterior-stabilized (PS) total knee arthroplasty uses a mechanism involving a tibial post and femoral cam to replace the function of the posterior cruciate ligament.
  • *Some patients experience a clicking sensation and wear/fracture of the post, possibly due to high impact velocity during engagement.
  • *The study evaluated different TKA designs through simulation and analysis, finding that factors like condylar geometry influence post-cam engagement dynamics and stresses, which can inform better implant design.