In this study, we investigate the performance of advanced 2D acquisition geometries - Pentagon and T-shaped - in digital breast tomosynthesis (DBT) and compare them against the conventional 1D geometry. Unlike the conventional approach, our proposed 2D geometries also incorporate anterior projections away from the chest wall. Implemented on the Next-Generation Tomosynthesis (NGT) prototype developed by X-ray Physics Lab (XPL), UPenn, we utilized various phantoms to compare three geometries: a Defrise slab phantom with alternating plastic slabs to study low-frequency modulation; a Checkerboard breast phantom (a 2D adaptation of the Defrise phantom design) to study the ability to reconstruct the fine features of the checkerboard squares; and the 360° Star-pattern phantom to assess aliasing and compute the Fourier-spectral distortion (FSD) metric that assesses spectral leakage and the contrast transfer function.
View Article and Find Full Text PDFThe adoption of artificial intelligence (AI) in medical imaging requires careful evaluation of machine-learning algorithms. We propose the use of a "deep virtual clinical trial" (DeepVCT) method to effectively evaluate the performance of AI algorithms. In this paper, DeepVCTs have been proposed to elucidate limitations of AI applications and predictions of clinical outcomes, avoiding biases in study designs.
View Article and Find Full Text PDFBackground: A next generation tomosynthesis (NGT) system, capable of two-dimensional source motion, detector motion in the perpendicular direction, and magnification tomosynthesis, was constructed to investigate different acquisition geometries. Existing position-based geometric calibration methods proved ineffective when applied to the NGT geometries.
Purpose: A line-based iterative calibration method is developed to perform accurate geometric calibration for the NGT system.
Our lab at the University of Pennsylvania (UPenn) is investigating novel designs for digital breast tomosynthesis. We built a next-generation tomosynthesis system with a non-isocentric geometry (superior-to-inferior detector motion). This paper examines four metrics of image quality affected by this design.
View Article and Find Full Text PDFObjectives: A virtual clinical trial (VCT) method is proposed to determine the limit of calcification detection in tomosynthesis.
Methods: Breast anatomy, focal findings, image acquisition, and interpretation (n = 14 readers) were simulated using screening data (n = 660 patients). Calcifications (0.
Proc SPIE Int Soc Opt Eng
February 2023
Tomosynthesis acquires projections over a limited angular range, resulting in anisotropic sampling in the Fourier domain. The volume of the sampled space is therefore spatially dependent; different Fourier components are sampled for the same object, depending upon where the object is located relative to the system origin. A next-generation tomosynthesis (NGT) system was developed at the University of Pennsylvania to increase the spatial isotropy in DBT, by incorporating additional system motions.
View Article and Find Full Text PDFDigital breast tomosynthesis (DBT) reconstructions introduce out-of-plane artifacts and false-tissue boundaries impacting the dense/adipose and breast outline (convex hull) segmentations. A virtual clinical trial method was proposed to segment both the breast tissues and the breast outline in DBT reconstructions. The DBT images of a representative population were simulated using three acquisition geometries: a left-right scan (conventional, I), a two-directional scan in the shape of a "T" (II), and an extra-wide range (XWR, III) left-right scan at a six-times higher dose than I.
View Article and Find Full Text PDFIn breast tomosynthesis, multiple low-dose projections are acquired in a single scanning direction over a limited angular range to produce cross-sectional planes through the breast for three-dimensional imaging interpretation. We built a next-generation tomosynthesis system capable of multidirectional source motion with the intent to customize scanning motions around "suspicious findings". Customized acquisitions can improve the image quality in areas that require increased scrutiny, such as breast cancers, architectural distortions, and dense clusters.
View Article and Find Full Text PDFThe use of nanoparticles in the biomedical field has gained much attention due to their applications in biomedical imaging, drug delivery, and therapeutics. Silver telluride nanoparticles (AgTe NPs) have been recently shown to be highly effective computed tomography (CT) and dual-energy mammography contrast agents with good stability and biocompatibility, as well as to have potential for many other biomedical purposes. Despite their numerous advantageous properties for diagnosis and treatment of disease, the clinical translation of AgTe NPs is dependent on achieving high levels of excretion, a limitation for many nanoparticle types.
View Article and Find Full Text PDFOur lab has built a next-generation tomosynthesis (NGT) system utilizing scanning motions with more degrees of freedom than clinical digital breast tomosynthesis systems. We are working toward designing scanning motions that are customized around the locations of suspicious findings. The first step in this direction is to demonstrate that these findings can be detected with a single projection image, which can guide the remainder of the scan.
View Article and Find Full Text PDFX-ray imaging results in inhomogeneous irradiation of the detector and distortion of structures in the periphery of the image; yet the spatial dependency of tomosynthesis image-quality metrics has not been extensively investigated. In this study, we use virtual clinical trials to quantify the spatial dependency of lesion detectability in our lab's next-generation tomosynthesis (NGT) system. Two geometries were analyzed: a conventional geometry with mediolateral source motion, and a NGT geometry with T-shaped motion.
View Article and Find Full Text PDFThe reproducibility of handcrafted radiomic features (HRFs) has been reported to be affected by variations in imaging parameters, which significantly affect the generalizability of developed signatures and translation to clinical practice. However, the collective effect of the variations in imaging parameters on the reproducibility of HRFs remains unclear, with no objective measure to assess it in the absence of reproducibility analysis. We assessed these effects of variations in a large number of scenarios and developed the first quantitative score to assess the reproducibility of CT-based HRFs without the need for phantom or reproducibility studies.
View Article and Find Full Text PDFPurpose: Virtual clinical trials (VCTs) require computer simulations of representative patients and images to evaluate and compare changes in performance of imaging technologies. The simulated images are usually interpreted by model observers whose performance depends upon the selection of imaging cases used in training evaluation models. This work proposes an efficient method to simulate and calibrate soft tissue lesions, which matches the detectability threshold of virtual and human readings.
View Article and Find Full Text PDFVirtual clinical trials (VCTs) have been used widely to evaluate digital breast tomosynthesis (DBT) systems. VCTs require realistic simulations of the breast anatomy (phantoms) to characterize lesions and to estimate risk of masking cancers. This study introduces the use of Perlin-based phantoms to optimize the acquisition geometry of a novel DBT prototype.
View Article and Find Full Text PDFA next generation tomosynthesis (NGT) prototype has been developed to investigate alternative scanning geometries for digital breast tomosynthesis (DBT). The NGT system uses a 2D plane as an address space for the x-ray source to define an acquisition geometry. In previous work, tests of physics have been used as objective metrics to evaluate image quality for NGT.
View Article and Find Full Text PDFWe have constructed a prototype next-generation tomosynthesis (NGT) system that supports a non-isocentric acquisition geometry for digital breast tomosynthesis (DBT). In this geometry, the detector gradually descends in the superior-to-inferior direction. The aim of this work is to demonstrate that this geometry offers isotropic super-resolution (SR), unlike clinical DBT systems which are characterized by anisotropies in SR.
View Article and Find Full Text PDFMost current nanoparticle formulations have relatively low clearance efficiency, which may hamper their likelihood for clinical translation. Herein, we sought to compare the clearance and cellular distribution profiles between sub-5 nm, renally-excretable silver sulfide nanoparticles (AgS-NPs) synthesized via either a bulk, high temperature, or a microfluidic, room temperature approach. We found that the thermolysis approach led to significant ligand degradation, but the surface coating shell was unaffected by the microfluidic synthesis.
View Article and Find Full Text PDFSilver chalcogenide (AgX, where X = S, Se, or Te) nanoparticles have been extensively investigated for their applications in electronics but have only recently been explored for biomedical applications. In the past 10 years, AgX, primarily silver sulfides at first, have become of great importance as quantum dots, since they not only possess excellent deep tissue imaging properties in the near-infrared regions I and II, but also have low toxicities. Their appealing properties have led to numerous recent developments of AgX for biomedical applications.
View Article and Find Full Text PDFDigital mammography has seen an explosion in the number of radiomic features used for risk-assessment modeling. However, having more features is not necessarily beneficial, as some features may be overly sensitive to imaging physics (contrast, noise, and image sharpness). To measure the effects of imaging physics, we analyzed the feature variation across imaging acquisition settings (kV, mAs) using an anthropomorphic phantom.
View Article and Find Full Text PDFBackground While digital breast tomosynthesis (DBT) is rapidly replacing digital mammography (DM) in breast cancer screening, the potential of DBT density measures for breast cancer risk assessment remains largely unexplored. Purpose To compare associations of breast density estimates from DBT and DM with breast cancer. Materials and Methods This retrospective case-control study used contralateral DM/DBT studies from women with unilateral breast cancer and age- and ethnicity-matched controls (September 19, 2011-January 6, 2015).
View Article and Find Full Text PDFThe dark-field signal measures the small-angle scattering strength and provides complementary diagnostic information. This is of particular interest for lung imaging due to the pronounced small-angle scatter from the alveolar microstructure. However, most dark-field imaging techniques are relatively complex, dose-inefficient, and require sophisticated optics and highly coherent X-ray sources.
View Article and Find Full Text PDFCancers (Basel)
June 2021
We would like to thank Orlhac and Buvat [...
View Article and Find Full Text PDFRadiat Prot Dosimetry
October 2021
Virtual clinical trials (VCTs) can be used to evaluate and optimise medical imaging systems. VCTs are based on computer simulations of human anatomy, imaging modalities and image interpretation. OpenVCT is an open-source framework for conducting VCTs of medical imaging, with a particular focus on breast imaging.
View Article and Find Full Text PDF