Background: One of the most prevalent health problems affecting children worldwide is untreated caries in primary teeth. Agents to arrest caries are used to manage untreated decay in children in disadvantaged communities. Nano Silver Fluoride (NSF) overcomes the staining problems of Silver Diamine Fluoride (SDF).
View Article and Find Full Text PDFIntroduction: Transforming Growth Factor-Beta 1 (TGF-β1) plays a crucial role in the success of Regenerative Endodontic Procedures (REPs) as they directly impact the proliferation and differentiation of stem cells. TGF-β1 is released by conditioning of the dentin matrix using 17% EDTA. EDTA was found to have deleterious effects on dentin especially in immature teeth with fragile dentin walls.
View Article and Find Full Text PDFBiomed Phys Eng Express
April 2024
In current radiograph-based intra-fraction markerless target-tracking, digitally reconstructed radiographs (DRRs) from planning CTs (CT-DRRs) are often used to train deep learning models that extract information from the intra-fraction radiographs acquired during treatment. Traditional DRR algorithms were designed for patient alignment (bone matching) and may not replicate the radiographic image quality of intra-fraction radiographs at treatment. Hypothetically, generating DRRs from pre-treatment Cone-Beam CTs (CBCT-DRRs) with DRR algorithms incorporating physical modelling of on-board-imagers (OBIs) could improve the similarity between intra-fraction radiographs and DRRs by eliminating inter-fraction variation and reducing image-quality mismatches between radiographs and DRRs.
View Article and Find Full Text PDFObjectives: Untreated caries in primary teeth is one of the most prevalent health problems in children worldwide. Silver diamine fluoride (SDF) non-invasively arrests caries but causes staining unlike Nano Silver Fluoride (NSF) which causes no stains. This study compared the effect of NSF and 38 % SDF on the oral health related quality of life (OHRQoL) of preschool children after 6 months.
View Article and Find Full Text PDFObjective: To explore hospital-level care for pre-eclampsia in Ethiopia, considering the perspectives of those affected and healthcare providers, in order to understand barriers and facilitators to early detection, care escalation and appropriate management.
Setting: A primary and a general hospital in southern Ethiopia.
Participants: Women with lived experience of pre-eclampsia care in the hospital, families of women deceased due to pre-eclampsia, midwives, doctors, integrated emergency surgical officers and healthcare managers.
Real-time target position verification during pancreas stereotactic body radiation therapy (SBRT) is important for the detection of unplanned tumour motions. Fast and accurate fiducial marker segmentation is a Requirement of real-time marker-based verification. Deep learning (DL) segmentation techniques are ideal because they don't require additional learning imaging or prior marker information (e.
View Article and Find Full Text PDFBackground: To evaluate the analgesic efficacy and spread of variable volumes of local anesthetics (LA) in Erector spinae plane block (ESPB).
Methods: Sixty patients aged between 18 and 50 years with an ASA I-II and scheduled for breast cancer surgery were randomized to receive either ESPB with 20 ml 0.25% bupivacaine (Standard volume ESPB), or with 40 ml 0.
Background: Tuberculous meningitis is a serious public health problem, particularly in low-income countries. It is associated with high rates of mortality and morbidity. The outcome of tuberculous meningitis in children is not well documented in Ethiopia, particularly in eastern Ethiopia.
View Article and Find Full Text PDFBackground: Preeclampsia is a well-known cause of maternal mortality and morbidity in Ethiopia. The exact pathophysiology has not been fully understood. Calcium and magnesium deficiencies have been given emphasis to play roles in the pathophysiology.
View Article and Find Full Text PDFThe purpose of this work is to develop a validated Geant4 simulation model of a whole-body prototype PET scanner constructed from the four-layer depth-of-interaction detectors developed at the National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Japan. The simulation model emulates the behaviour of the unique depth of interaction sensing capability of the scanner without needing to directly simulate optical photon transport in the scintillator and photodetector modules. The model was validated by evaluating and comparing performance metrics from the NEMA NU 2-2012 protocol on both the simulated and physical scanner, including spatial resolution, sensitivity, scatter fraction, noise equivalent count rates and image quality.
View Article and Find Full Text PDFTime-of-flight (TOF) is now a standard technology for positron emission tomography (PET), but its effective use for small diameter PET systems has not been studied well. In this paper, we simulated a brain-dedicated TOF-PET system with a hemispherical detector arrangement. We modeled a Hamamatsu TOF-PET module (C13500-4075LC-12) with 280 ps coincidence resolving time (CRT), in which a 12 × 12 array of multi pixel photon counters (MPPCs) is connected to a lutetium fine silicate (LFS) crystal array of 4.
View Article and Find Full Text PDFEuropean J Pediatr Surg Rep
January 2019
A male infant aged 45 days presented with projectile nonbilious vomiting for 2 weeks. Ultrasound showed picture of idiopathic hypertrophic pyloric stenosis. Laparoscopic pyloromyotomy was done, but postoperative vomiting that was mainly nonbilious continued without improvement.
View Article and Find Full Text PDFIn this study, we investigated the influence of betaine (Bet, 1000 mg/kg), with or without vitamin C (VC, 200 mg/kg ascorbic acid) and/or vitamin E (VE, 150 mg/kg α-tocopherol acetate) on semen quality, seminal and blood plasma constituents, antioxidants' status, DNA repair, and the welfare of chronic heat stress (CHS)-exposed roosters. A total of 54 roosters were divided into six groups of nine replicates. One group was kept under thermoneutral conditions, whereas the other five were kept under CHS.
View Article and Find Full Text PDFThe distribution of fragmentation products predicted by Monte Carlo simulations of heavy ion therapy depend on the hadronic physics model chosen in the simulation. This work aims to evaluate three alternative hadronic inelastic fragmentation physics options available in the Geant4 Monte Carlo radiation physics simulation framework to determine which model most accurately predicts the production of positron-emitting fragmentation products observable using in-beam PET imaging. Fragment distributions obtained with the BIC, QMD, and INCL + + physics models in Geant4 version 10.
View Article and Find Full Text PDFThe dominant factor limiting the intrinsic spatial resolution of a positron emission tomography (PET) system is the size of the crystal elements in the detector. To increase sensitivity and achieve high spatial resolution, it is essential to use advanced depth-of-interaction (DOI) detectors and arrange them close to the subject. The DOI detectors help maintain high spatial resolution by mitigating the parallax error caused by the thickness of the scintillator near the peripheral regions of the field-of-view.
View Article and Find Full Text PDFMuch research effort is being made to increase the sensitivity and improve the imaging performance of positron emission tomography (PET) scanners. Conventionally, sensitivity can be increased by increasing the number of detector rings in the axial direction (but at high cost) or reducing the diameter of the scanner (with the disadvantages of reducing the space for patients and degrading the spatial resolution due to the parallax error). In this study, we proposed a PET scanner with a truncated ring and an array of detectors that can be arranged in a straight line below the bed.
View Article and Find Full Text PDFBackground: The hysteroscopic surgery has become a simple and safe technique, with the use of small hysteroscopes and bipolar energy with trained surgeons, which can prevent abortions and probably increase fertility.
Aim: The study was conducted to evaluate the outcomes after hysteroscopic surgery by using uninopolar or bipolar electrodes.
Setting And Design: At the department of Obstetrics and Gynaecology, Qena university hospital and is a prospective non randomized clinical study.
Radiol Phys Technol
January 2015
A system matrix (SM) is the basic component of iterative image reconstruction algorithms. Calculation of the SM needs a considerable amount of time due to an enormous number of lines of response (LORs) being modeled. In this study, we developed a technique based on a piece-wise calculation method in which symmetry and further division of the voxels are applied.
View Article and Find Full Text PDFComplications of an unsafe abortion are a major contributor to maternal deaths and morbidity in Africa. When abortions are performed in safe environments, such complications are almost all preventable. This paper reports results from a nationally representative health facility study conducted in Ethiopia in 2008.
View Article and Find Full Text PDFInt Perspect Sex Reprod Health
March 2010
Context: Unsafe abortion is an important health problem in Ethiopia; however, no national quantitative study of abortion incidence exists. In 2005, the penal code was revised to broaden the indications under which induced abortion is legal. It is important to measure the incidence of legal and illegal induced abortion after the change in the law.
View Article and Find Full Text PDFInt Perspect Sex Reprod Health
March 2010
Context: Ethiopia liberalized its abortion law in 2005, primarily to reduce the incidence of unsafe abortion. However, little is known about the current extent and consequences of unsafe abortion.
Methods: Data were collected in 2007-2008 on 1,932 women seeking postabortion care at a nationally representative sample of 344 public and private health facilities.