Publications by authors named "Aarti A Shenoy"

Background: Modular dual mobility (MDM) acetabular component use is rising in total hip arthroplasty. However, concern of mechanically assisted crevice corrosion (MACC) at the shell-liner interface remains. We investigated shell-liner corrosion using retrieval analyses and corrosion chamber testing.

View Article and Find Full Text PDF

Background: Fractures of the polyethylene post are a rare but known complication after posterior-stabilized (PS) total knee arthroplasty (TKA). We evaluated the polyethylene and patient characteristics for 33 primary PS polyethylene components that were revised with fractured posts.

Methods: We identified 33 PS inserts revised between 2015 and 2022.

View Article and Find Full Text PDF

Corrosion of modular metal-on-metal acetabular tapers in total hip arthroplasty (THA) systems is often attributed to mechanically driven processes. Recent findings suggest that mechanically assisted crevice corrosion (MACC) might not be the dominant cause of corrosion in shell-liner tapers. This study aims to document and present the corrosion modes observed in metal-metal acetabular liners.

View Article and Find Full Text PDF

Wear and corrosion damage of biomedical alloys alters the structure and electrochemical properties of the surface heterogeneously. It was hypothesized that local regions on the same surface systematically differ from one another in terms of their impedance characteristics. To test this hypothesis, CoCrMo disks exposed to electrosurgical and inflammatory-species-driven damage were characterized using a localized impedance technique, nearfield electrochemical impedance spectroscopy (NEIS), to assess point-specific surface integrity in response to applied damage.

View Article and Find Full Text PDF

Retrieval studies show that metal-on-metal acetabular shell-liner tapers are susceptible to corrosion, which is hypothesized to arise from mechanically-assisted crevice corrosion (MACC). The role of materials on MACC of acetabular tapers has not been previously studied. In vitro tests of seating, pushout, and fretting corrosion performance of acetabular tapers are presented to assess the role of material combinations (Ti-6Al-4V shells, HC CoCrMo, LC CoCrMo, and 316L SS liners).

View Article and Find Full Text PDF

The mechanically assisted crevice corrosion performance of head-neck modular tapers is a significant concern in orthopedic biomaterials. Fretting crevice corrosion processes in modular tapers are thought to be influenced by a wide array of factors including seating mechanics of the junction, hence there is a need for in vitro test methods that can assess their performance. This study presented a test method to directly measure the load-displacement seating mechanics of modular tapers and used this method to compare the seating mechanics for different tapers, moisture, seating loads and seating rates.

View Article and Find Full Text PDF