The risk of developing a severe delayed cutaneous reaction (SCAR) is very low following iodine-based contrast medium (ICM) administration and extremely low following gadolinium-based contrast agent (GBCA) administration. However, SCAR can be very severe and potentially life-threatening. It is crucial for the imaging physician to recognize danger signals: bullous skin eruption, skin erosion and detachment, mucosal involvement, systemic symptoms, and laboratory abnormalities.
View Article and Find Full Text PDFThe risk of hypersensitivity reactions (HSR) following nonvascular administration of contrast media (CM) for diagnostic studies is very low, likely due to minimal absorption into the systemic circulation. Most published individual cases of HSR after nonvascular CM administration are immediate reactions caused by ionic high-osmolar CM, few by nonionic low-osmolar CM, and none by gadolinium-based contrast agents. Measures to prevent recurrent HSR following nonvascular administration are similar to those recommended to prevent HSR after intravascular CM administration.
View Article and Find Full Text PDFBackground: Metallic artefacts caused by metal implants, are a common problem in computed tomography (CT) imaging, degrading image quality and diagnostic accuracy. With advancements in artificial intelligence, novel deep learning (DL)-based metal artefact reduction (MAR) algorithms are entering clinical practice.
Objective: This systematic review provides an overview of the performance of the current supervised DL-based MAR algorithms for CT, focusing on three different domains: sinogram, image, and dual domain.
The standard treatment regimen for esophageal cancer is chemoradiation followed by esophagectomy. However, the use of neoadjuvant chemoradiotherapy damages the surrounding tissue, which potentially increases the risk of postoperative complications, including anastomotic leakage. The impact of definitive chemoradiotherapy (dCRT, 50.
View Article and Find Full Text PDFEur Radiol
December 2024
Objectives: Hysterosalpingography (HSG) is widely used for evaluating the fallopian tubes; however, controversies regarding the use of water- or oil-based iodine-based contrast media (CM) remain. The aim of this work was (1) to discuss reported pregnancy rates related to the CM type used, (2) to validate the used CM in published literature, (3) to discuss possible complications and side effects of CM in HSG, and (4) to develop guidelines on the use of oil-based CM in HSG.
Methods: A systematic literature search was conducted for original RCT studies or review/meta-analyses on using water-based and oil-based CM in HSG with fertility outcomes and complications.
Gadolinium-based contrast agents (GBCA) are essential for diagnostic MRI examinations. GBCA are only used in small quantities on a per-patient basis; however, the acquisition of contrast-enhanced MRI examinations worldwide results in the use of many thousands of litres of GBCA per year. Data shows that these GBCA are present in sewage water, surface water, and drinking water in many regions of the world.
View Article and Find Full Text PDFThe acquisition of images minutes or even hours after intravenous extracellular gadolinium-based contrast agents (GBCA) administration ("Late/Delayed Gadolinium Enhancement" imaging; in this review, further termed LGE) has gained significant prominence in recent years in magnetic resonance imaging. The major limitation of LGE is the long examination time; thus, it becomes necessary to understand when it is worth waiting time after the intravenous injection of GBCA and which additional information comes from LGE. LGE can potentially be applied to various anatomical sites, such as heart, arterial vessels, lung, brain, abdomen, breast, and the musculoskeletal system, with different pathophysiological mechanisms.
View Article and Find Full Text PDFObjectives: It is uncertain whether modern iodine-based or gadolinium-based contrast media (CM) administration can lead to increased symptoms in patients with myasthenia gravis.
Methods: A systematic search in Medline was conducted for studies describing the symptomatology of myasthenia gravis patients before and after receiving intravenous (IV) CM and having a matched control group of myasthenia gravis patients who did not receive IV CM.
Results: Three retrospective studies were selected with a total of 374 myasthenia gravis patients who received iodine-based CM and a total of 313 myasthenia gravis patients who underwent unenhanced CT and served as controls.
The Contrast Media Safety Committee of the European Society of Urogenital Radiology has, together with the Preanalytical Phase Working Group of the EFLM Science Committee, reviewed the literature and updated its recommendations to increase awareness and provide insight into these interferences. CLINICAL RELEVANCE STATEMENT: Contrast Media may interfere with clinical laboratory tests. Awareness of potential interference may prevent unwanted misdiagnosis.
View Article and Find Full Text PDFThe Contrast Media Safety Committee of the European Society of Urogenital Radiology has, together with the Preanalytical Phase Working Group of the EFLM Science Committee, reviewed the literature and updated its recommendations to increase awareness and provide insight into these interferences.
View Article and Find Full Text PDFBackground And Objective: In recent years, there has been a large-scale dissemination of guidelines in radiology in the form of Reporting & Data Systems (RADS). The use of iodinated contrast media (ICM) has a fundamental role in enhancing the diagnostic capabilities of computed tomography (CT) but poses certain risks. The scope of the present review is to summarize the current role of ICM only in clinical reporting guidelines for CT that have adopted the "RADS" approach, focusing on three specific questions per each RADS: (I) what is the scope of the scoring system; (II) how is ICM used in the scoring system; (III) what is the impact of ICM enhancement on the scoring.
View Article and Find Full Text PDFThe pharmacokinetics of contrast media (CM) will determine how long safe waiting intervals between successive CT or MRI examinations should be. The Contrast Media Safety Committee has reviewed the data on pharmacokinetics of contrast media to suggest safe waiting intervals between successive contrast-enhanced imaging studies in relation to the renal function of the patient. CLINICAL RELEVANCE STATEMENT: Consider a waiting time between elective contrast-enhanced CT and (coronary) angiography with successive iodine-based contrast media administrations in patients with normal renal function (eGFR > 60 mL/min/1.
View Article and Find Full Text PDFIn 2014, for the first time, visible hyperintensities on unenhanced T1-weighted images in the nucleus dentatus and globus pallidus of the brain were associated with previous Gadolinium-based contrast agent (GBCA) injections and gadolinium deposition in patients with normal renal function. This led to a frenzy of retrospective studies with varying methodologies that the European Society of Magnetic Resonance in Medicine and Biology Gadolinium Research and Educational Committee (ESMRMB-GREC) summarised in 2019. Now, after 10 years, the members of the ESMRMB-GREC look backward and forward and review the current state of knowledge of gadolinium retention and deposition.
View Article and Find Full Text PDFAmong the 28 reporting and data systems (RADS) available in the literature, we identified 15 RADS that can be used in Magnetic Resonance Imaging (MRI). Performing examinations without using gadolinium-based contrast agents (GBCA) has benefits, but GBCA administration is often required to achieve an early and accurate diagnosis. The aim of the present review is to summarize the current role of GBCA in MRI RADS.
View Article and Find Full Text PDFMagnetic resonance imaging (MRI) is the most sensitive technique for detecting inflammatory demyelinating lesions in multiple sclerosis (MS) and plays a crucial role in diagnosis and monitoring treatment effectiveness, and for predicting the disease course. In clinical practice, detection of MS lesions is mainly based on T2-weighted and contrast-enhanced T1-weighted sequences. Contrast-enhancing lesions (CEL) on T1-weighted sequences are related to (sub)acute inflammation, while new or enlarging T2 lesions reflect the permanent footprint from a previous acute inflammatory demyelinating event.
View Article and Find Full Text PDFObjectives: The aim of this study was to summarize the current preclinical and clinical evidence on the association between exposure to gadolinium (Gd) compounds and skin toxicity in a setting similar to clinical practice.
Materials And Methods: A search of MEDLINE and PubMed references from January 2000 to December 2022 was performed using keywords related to gadolinium deposition and its effects on the skin, such as "gadolinium," "gadolinium-based contrast agents," "skin," "deposition," and "toxicity." In addition, cross-referencing was added when appropriate.