Publications by authors named "Aaron M Barlow"

Background: The implications and potential challenges of coronary access after redo transcatheter aortic valve replacement (TAVR) are unknown.

Objectives: The authors sought to evaluate the impact of different transcatheter heart valve (THV) designs, neoskirt height, implant technique, and cell misalignment on coronary access after redo TAVR.

Methods: Different THV designs (Sapien 3 [Edwards Lifesciences LLC], Evolut Pro [Medtronic], ACURATE neo [Boston Scientific Corporation], and Portico [Abbott Structural Heart]) and sizes were implanted inside Sapien XT (Edwards Lifesciences LLC) and Evolut R (Medtronic) THVs, which were modeled as the "failed" THVs, at different implant depths.

View Article and Find Full Text PDF

Multiphoton microscopy is a powerful, non-invasive technique to image biological specimens. One current limitation of multiphoton microscopy is resolution as many of the biological molecules and structures investigated by research groups are similar in size or smaller than the diffraction limit. To date, the combination of multiphoton and super-resolution imaging has proved technically challenging for biology focused laboratories to implement.

View Article and Find Full Text PDF

Aims: Bioprosthetic valve fracture (BVF) may improve transvalvular gradients and transcatheter heart valve (THV) expansion during VIV interventions. However, the optimal timing of BVF is unknown. We assessed the impact of timing of BVF (before versus after) for valve-in-valve (VIV) intervention, on hydrodynamic function and THV expansion.

View Article and Find Full Text PDF

Objectives: We undertook an independent bench test assessing the performance of the TRUE dilatation (TD) balloon valvuloplasty catheter (Bard Vascular Inc., Tempe, AZ) beyond its rated burst pressure (RBP).

Background: The TD balloon has a RBP of six atmospheres (atm), and its performance beyond this RBP is poorly understood.

View Article and Find Full Text PDF

Objectives: The authors assessed the effect of valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) followed by bioprosthetic valve fracture (BVF), testing different transcatheter heart valve (THV) designs in an ex vivo bench study.

Background: Bioprosthetic valve fracture can be performed to improve residual transvalvular gradients following VIV TAVR.

Methods: The authors evaluated VIV TAVR and BVF with the SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, California) and ACURATE neo (Boston Scientific Corporation, Natick, Massachusetts) THVs.

View Article and Find Full Text PDF

We consider multi-modal four-wave mixing microscopies to be ideal tools for the in vivo study of carotenoid distributions within the important biofuel microalgae Haematococcus pluvialis. We show that hyperspectral coherent anti-Stokes Raman scattering (CARS) microscopy generates non-invasive, quantitative real-time concentrations maps of intracellular carotenoid distributions in live algae.

View Article and Find Full Text PDF

Coherent anti-Stokes Raman scattering (CARS) microscopy is a third-order nonlinear optical technique which permits label-free, molecule-specific hyperspectral imaging. The interference between coherent resonant and non-resonant terms leads to well known distortions in the vibrational spectrum, requiring the use of retrieval algorithms. It also leads to spatial imaging distortions, largely due to the Gouy phase, when objects are smaller than the Rayleigh range.

View Article and Find Full Text PDF