Publications by authors named "AW Stevenson"

After burn injury there is considerable variation in scar outcome, partially due to genetic factors. Scar vascularity is one characteristic that varies between individuals, and this study aimed to identify genetic variants contributing to different scar vascularity outcomes. An exome-wide array association study and gene pathway analysis was performed on a prospective cohort of 665 patients of European ancestry treated for burn injury, using their scar vascularity (SV) sub-score, part of the modified Vancouver Scar Scale (mVSS), as an outcome measure.

View Article and Find Full Text PDF

Burn injuries are devastating traumas, often leading to life-long consequences that extend beyond the observable burn scar. In the context of the nervous system, burn injury patients commonly develop chronic neurological disorders and have been suggested to have impaired motor cortex function, but the long-lasting impact on neurons and glia in the brain is unknown. Using a mouse model of non-severe burn injury, excitatory and inhibitory neurons in the primary motor cortex were labelled with fluorescent proteins using adeno-associated viruses (AAVs).

View Article and Find Full Text PDF

Individuals who present to a hospital for treatment of a burn of any magnitude are more frequently hospitalised for ischemic heart disease, even decades after injury. Blood platelets are key mediators of cardiovascular disease. To investigate platelet involvement in post-burn cardiovascular risk, platelet reactivity was assessed in patients at 2- and 6-weeks after non-severe (TBSA < 20%) burn injury, and in a murine model 30 days after 8% TBSA full-thickness burn injury.

View Article and Find Full Text PDF

Scarring is a lifelong consequence of skin injury, with scar stiffness and poor appearance presenting physical and psychological barriers to a return to normal life. Lysyl oxidases are a family of enzymes that play a critical role in scar formation and maintenance. Lysyl oxidases stabilize the main component of scar tissue, collagen, and drive scar stiffness and appearance.

View Article and Find Full Text PDF

We investigate how an intrinsic speckle tracking approach to speckle-based x-ray imaging is used to extract an object's effective dark-field (DF) signal, which is capable of providing object information in three dimensions. The effective DF signal was extracted using a Fokker-Planck type formalism, which models the deformations of illuminating reference beam speckles due to both coherent and diffusive scatter from the sample. Here, we assumed that (a) small-angle scattering fans at the exit surface of the sample are rotationally symmetric and (b) the object has both attenuating and refractive properties.

View Article and Find Full Text PDF

Burn injuries are common and often life-threatening trauma. With this trauma comes an interruption of normal hemostasis, with distinct impacts on platelets. Our interest in the relationships between burn injury and platelet function stems from two key perspectives: platelet function is a vital component of acute responses to injury, and furthermore the incidence of cardiovascular disease (CVD) is higher in burn survivors compared to the general population.

View Article and Find Full Text PDF

Scars are maintained for life and increase in size during periods of growth such as puberty. Epigenetic changes in fibroblasts after injury may underpin the maintenance and growth of scars. In this study, we combined methylome and transcriptome data from normotrophic mature scar and contralateral uninjured normal skin fibroblasts to identify potential regulators of scar maintenance.

View Article and Find Full Text PDF

Background: Fibroblasts found in keloid tissues are known to present an altered sensitivity to microenvironmental stimuli. However, the impact of changes in extracellular matrix stiffness on phenotypes of normal fibroblasts (NFs) and keloid fibroblasts (KFs) is poorly understood.

Objectives: Investigation the impact of matrix stiffness on NFs and KFs mainly via detecting yes-associated protein (YAP) expression.

View Article and Find Full Text PDF

Keloid scarring is a fibroproliferative disorder of the skin with unknown pathophysiology, characterised by fibrotic tissue that extends beyond the boundaries of the original wound. Therapeutic options are few and commonly ineffective, with keloids very commonly recurring even after surgery and adjunct treatments. Epigenetics, defined as alterations to the DNA not involving the base-pair sequence, is a key regulator of cell functions, and aberrant epigenetic modifications have been found to contribute to many pathologies.

View Article and Find Full Text PDF

Synchrotron radiation, especially microbeam radiotherapy (MRT), has a great potential to improve cancer radiotherapy, but non-targeted effects of synchrotron radiation have not yet been sufficiently explored. We have previously demonstrated that scattered synchrotron radiation induces measurable -H2AX foci, a biomarker of DNA double-strand breaks, at biologically relevant distances from the irradiated field that could contribute to the apparent accumulation of bystander DNA damage detected in cells and tissues outside of the irradiated area. Here, we quantified an impact of scattered radiation to DNA damage response in "naïve" cells sharing the medium with the cells that were exposed to synchrotron radiation.

View Article and Find Full Text PDF

Abscopal effects are an important aspect of targeted radiation therapy due to their implication in normal tissue toxicity from chronic inflammatory responses and mutagenesis. Gene expression can be used to determine abscopal effects at the molecular level. Synchrotron microbeam radiation therapy utilizing high-intensity X rays collimated into planar microbeams is a promising cancer treatment due to its reported ability to ablate tumors with less damage to normal tissues compared to conventional broadbeam radiation therapy techniques.

View Article and Find Full Text PDF

Experimental measurement of Synchrotron Radiotherapy (SyncRT) doses is challenging, especially for Microbeam Radiotherapy (MRT), which is characterised by very high dynamic ranges with spatial resolutions on the micrometer scale. Monte Carlo (MC) simulation is considered a gold standard for accurate dose calculation in radiotherapy, and is therefore routinely relied upon to produce verification data. We present a MC model for Australian Synchrotron's Imaging and Medical Beamline (IMBL), which is capable of generating accurate dosimetry data to inform and/or verify SyncRT experiments.

View Article and Find Full Text PDF

The timely resolution of wound healing is critical for restoring the skin as a protective barrier. The switch from a proinflammatory to a reparative microenvironment must be tightly regulated. Interleukin (IL)-6 is a key modulator of the inflammatory and reparative process: it is involved in the differentiation, activation, and proliferation of leukocytes, endothelial cells, keratinocytes, and fibroblasts.

View Article and Find Full Text PDF

Microbeam Radiation Therapy (MRT) is an emerging cancer treatment modality characterised by the use of high-intensity synchrotron-generated x-rays, spatially fractionated by a multi-slit collimator (MSC), to ablate target tumours. The implementation of an accurate treatment planning system, coupled with simulation tools that allow for independent verification of calculated dose distributions are required to ensure optimal treatment outcomes via reliable dose delivery. In this article we present data from the first Geant4 Monte Carlo radiation transport model of the Imaging and Medical Beamline at the Australian Synchrotron.

View Article and Find Full Text PDF

Purpose: Dosimetry of ionizing radiation in the presence of strong magnetic fields is gaining increased relevance in light of advances for MRI-guided radiation therapy. While the impact of strong magnetic fields on the overall response of ionization chambers has been simulated and measured before, this work investigates the local impact of the magnetic field on dose response in an ion chamber. High-resolution 1D and 2D response maps have been created for two small clinical thimble ionization chambers, the PinPoint chambers 31006 and 31014 (Physikalisch Technische Werkstaetten Freiburg, Germany).

View Article and Find Full Text PDF

Background: Synchrotron microbeam radiation therapy (MRT) is a new, evolving form of radiotherapy that has potential for clinical application. Several studies have shown in preclinical models that synchrotron MRT achieves equivalent tumor control to conventional radiotherapy (CRT) but with significantly reduced normal tissue damage.

Methods: To explore differences between these two modalities, we assessed the immune cell infiltrate into EMT6.

View Article and Find Full Text PDF

Purpose: Nontargeted effects of ionizing radiation, by which unirradiated cells and tissues are also damaged, are a relatively new paradigm in radiobiology. We recently reported radiation-induced abscopal effects (RIAEs) in normal tissues; namely, DNA damage, apoptosis, and activation of the local and systemic immune responses in C57BL6/J mice after irradiation of a small region of the body. High-dose-rate, synchrotron-generated broad beam or multiplanar x-ray microbeam radiation therapy was used with various field sizes and doses.

View Article and Find Full Text PDF

The principle of rotational summation of the absorbed dose for breast cancer treatment with orthovoltage X-ray beams was proposed by J. Boone in 2012. Here, use of X-ray synchrotron radiation for image guided external beam rotational radiotherapy treatment of breast cancer is proposed.

View Article and Find Full Text PDF

An important histological difference between normal, uninjured dermis and scar tissue such as that found in keloid scars is the pattern (morphological architecture) in which the collagen is deposited and arranged. In the uninjured dermis, collagen bundle architecture appears randomly organized (or in a basket weave formation), whereas in pathological conditions such as keloid scar tissue, collagen bundles are often found in whorls or in a hypotrophic scar collagen is more densely packed in a parallel configuration. In the case of skin, a scar disables the dermis, leaving it weaker, stiff and with a loss of optimal functionality.

View Article and Find Full Text PDF
Article Synopsis
  • Microbeam radiation therapy (MRT) is more effective at sparing normal tissues than broadbeam radiation and relies on maximizing the peak-to-valley dose ratio (PVDR) for optimal treatment outcomes.
  • Experimental investigations showed that PVDR increases with X-ray energy up to 100 keV and plateaus afterward, with the highest PVDR noted for a pink beam at an average energy of 124 keV.
  • The study identified that bone has minimal impact on PVDR at depths over 20 mm, concluding that the best energy range for MRT at the Imaging and Medical Beamline is 90-120 keV, specifically favoring a spectrum with a 95 keV average energy for optimal results
View Article and Find Full Text PDF

Purpose: To map the spatial response of four solid-state radiation detectors of types commonly used for radiotherapy dosimetry.

Methods: PTW model 60016 Diode P, 60017 Diode E, 60018 Diode SRS, and 60019 microDiamond detectors were radiographed using a high resolution conventional X-ray system. Their spatial response was then investigated using a 0.

View Article and Find Full Text PDF

The importance of nontargeted (systemic) effects of ionizing radiation is attracting increasing attention. Exploiting synchrotron radiation generated by the Imaging and Medical Beamline at the Australian Synchrotron, we studied radiation-induced nontargeted effects in C57BL/6 mice. Mice were locally irradiated with a synchrotron X-ray broad beam and a multiplanar microbeam radiotherapy beam.

View Article and Find Full Text PDF

It is shown that an extensive set of accurate ionization-chamber measurements with a primary polychromatic synchrotron X-ray beam transmitted through various filter combinations/thicknesses can be used to quite effectively estimate the absolute flux distribution. The basic technique is simple but the `inversion' of the raw data to extract the flux distribution is a fundamentally ill-posed problem. It is demonstrated, using data collected at the Imaging and Medical Beamline (IMBL) of the Australian Synchrotron, that the absolute flux can be quickly and reliably estimated if a suitable choice of filters is made.

View Article and Find Full Text PDF

Therapeutic applications of synchrotron X-rays such as microbeam (MRT) and minibeam (MBRT) radiation therapy promise significant advantages over conventional clinical techniques for some diseases if successfully transferred to clinical practice. Preclinical studies show clear evidence that a number of normal tissues in animal models display a tolerance to much higher doses from MRT compared with conventional radiotherapy. However, a wide spread in the parameters studied makes it difficult to make any conclusions about the associated tumour control or normal tissue complication probabilities.

View Article and Find Full Text PDF