Publications by authors named "AE Lange"

Intrauterine growth restriction leads to an altered lipid and amino acid profile in the cord blood at the end of pregnancy. Pre-pregnancy underweight is an early risk factor for impaired fetal growth. The aim of this study was to investigate whether a pre-pregnancy body mass index (ppBMI) of <18.

View Article and Find Full Text PDF

Background: Donor human milk is the recommended alternative for feeding preterm infants if mother's own milk is unavailable. Human milk banks collect, screen, store and distribute donated human milk according to pre-specified standard operating procedures to premature infants without mothers own milk.

Aim:   Herein we characterize current operating models and the structural organisation of German milk bank institutions.

View Article and Find Full Text PDF

Background: The German maternity guidelines require regular medical checkup (MC) during pregnancy as a measure of prevention. Socioeconomic factors such as education, profession, income and origin, but also age and parity may influence the preventive and health behavior of pregnant women. The aim was to investigate the influence of these factors on the participation rate in MC of pregnant women.

View Article and Find Full Text PDF

Purpose: The aim is to investigate the associations of the mother's socioeconomic and lifestyle factors and life satisfaction with the delivery of a small for gestational age (SGA) infant.

Methods: Data from 4598 participants of the population-based birth cohort study Survey of Neonates in Pomerania (SniP) including comprehensive information on pregnancies, mothers, and their offspring in Western Pomerania, Germany were used in this study. The associations were analyzed using linear and logistic regression models.

View Article and Find Full Text PDF

Aim: The aim was to investigate socio-economic risk factors for maternal underweight before pregnancy and then associations of underweight with neonatal outcomes.

Methods: Data of 3401 mother-child dyads from the population-based birth cohort Survey of Neonates in Pomerania (SNiP) were analysed.

Results: Bivariate analysis showed that underweighted mothers were younger, smoked more often, had a lower equivalent income and lower socio-economic status (employment status and/or educational level) compared to women with normal weight.

View Article and Find Full Text PDF

Background: The health status of newborns is a major concern for parents and medical personnel. Recent studies have provided increasing evidence that factors from the foetal and perinatal periods of life influence health later in life. The "Follow-up of the Survey of Neonates in Pomerania" (SNiP-I-Follow-up) is the first follow-up of the population-based birth cohort study, SNiP-I, established in north-east Germany.

View Article and Find Full Text PDF

Background: Recent guidelines recommend a cranial ultrasound (CU) in neonates born at < 30 weeks gestation, admitted to the neonatal intensive care unit (NICU), or with a CU indication. Here, we addressed the need to extend these recommendations.

Methods: We retrospectively reviewed 5107 CUs acquired in the population-based Survey of Neonates in Pomerania, conducted in 2002 to 2008.

View Article and Find Full Text PDF

Background: Gestational diabetes mellitus (GDM) is the most frequent complication during pregnancy. Untreated GDM is a severe threat to maternal and neonatal health. Based on recent evidence, up to 15% of all pregnancies may be affected by GDM.

View Article and Find Full Text PDF

Background: Some etiological factors involved in developmental dysplasia of the hip (DDH) occur in the last trimester of pregnancy, which could result in a decreased incidence of DDH in preterm infants. The aim of this study was to compare the incidence of DDH between preterm and term infants.

Methods: Ultrasound of the hip joint was performed in 2,534 term infants and 376 preterm infants within the population-based Survey of Neonates in Pomerania (SNiP) study.

View Article and Find Full Text PDF

Background: Congenital toxoplasmosis is associated with severe complications. German state health insurance covers rubella, but not toxoplasmosis, immunity screening. We analysed the effect of socioeconomic factors on the efficiency of private toxoplasmosis screening during pregnancy.

View Article and Find Full Text PDF

Background: The subject of "pregnancy and disease" is of particular importance for maternal well-being and neonatal outcomes. The international literature has focused on acute diseases during pregnancy; however, there are only a few studies investigating chronic diseases in pregnant women. The focus of this study is on diseases of women in childbearing age that are not related to the pregnancy.

View Article and Find Full Text PDF

Purpose: Congenital anomalies of the kidneys and urinary tract (CAKUT) are among the most common anomalies in newborn infants, and may cause chronic renal disease in newborns. We investigated the sensitivity and specificity of different ultrasound-based screening strategies for CAKUT.

Materials And Methods: Newborns (n = 4331) were analyzed for CAKUT in at least one ultrasound examination as a part of the Survey of Neonates in Pomerania (SNiP), a 7-year population-based study on neonates in Western Pomerania (Germany).

View Article and Find Full Text PDF

We constrain parity-violating interactions to the surface of last scattering using spectra from the QUaD experiment's second and third seasons of observations by searching for a possible systematic rotation of the polarization directions of cosmic microwave background photons. We measure the rotation angle due to such a possible "cosmological birefringence" to be 0.55 degrees +/-0.

View Article and Find Full Text PDF

We summarize the fabrication, flight qualification, and dark performance of bolometers completed at the Jet Propulsion Laboratory for the High Frequency Instrument (HFI) of the joint ESA/NASA Herschel/Planck mission to be launched in 2009. The HFI is a multicolor focal plane which consists of 52 bolometers operated at 100 mK. Each bolometer is mounted to a feedhorn-filter assembly which defines one of six frequency bands centered between 100-857 GHz.

View Article and Find Full Text PDF

Bolometers designed to detect submillimeter radiation also respond to cosmic, gamma, and x rays. Because detectors cannot be fully shielded from such energy sources, it is necessary to understand the effect of a photon or cosmic-ray particle being absorbed. The resulting signal (known as a glitch) can then be removed from raw data.

View Article and Find Full Text PDF

Far-infrared to millimeter-wave bolometers designed to make astronomical observations are typically encased in integrating cavities at the termination of feedhorns or Winston cones. This photometer combination maximizes absorption of radiation, enables the absorber area to be minimized, and controls the directivity of absorption, thereby reducing susceptibility to stray light. In the next decade, arrays of hundreds of silicon nitride micromesh bolometers with planar architectures will be used in ground-based, suborbital, and orbital platforms for astronomy.

View Article and Find Full Text PDF

Recent results from BOOMERANG-98 and MAXIMA-1, taken together with COBE DMR, provide consistent and high signal-to-noise measurements of the cosmic microwave background power spectrum at spherical harmonic multipole bands over 2 View Article and Find Full Text PDF

We use the angular power spectrum of the cosmic microwave background, measured during the North American test flight of the Boomerang experiment, to constrain the geometry of the universe. Within the class of cold dark matter models, we find that the overall fractional energy density of the universe Omega is constrained to be 0.85 View Article and Find Full Text PDF

We describe a measurement of the angular power spectrum of anisotropies in the cosmic microwave background (CMB) at scales of 0&fdg;3 to 5 degrees from the North American test flight of the Boomerang experiment. Boomerang is a balloon-borne telescope with a bolometric receiver designed to map CMB anisotropies on a long-duration balloon flight. During a 6 hr test flight of a prototype system in 1997, we mapped more than 200 deg(2) at high Galactic latitudes in two bands centered at 90 and 150 GHz with a resolution of 26&arcmin; and 16&farcm;5 FWHM, respectively.

View Article and Find Full Text PDF

The blackbody radiation left over from the Big Bang has been transformed by the expansion of the Universe into the nearly isotropic 2.73 K cosmic microwave background. Tiny inhomogeneities in the early Universe left their imprint on the microwave background in the form of small anisotropies in its temperature.

View Article and Find Full Text PDF

We report the design and performance of 300-mK composite bolometers that use micromesh absorbers and support structures patterned from thin films of low-stress silicon nitride. The small geometrical filling factor of the micromesh absorber provides 20x reduction in heat capacity and cosmic ray cross section relative to a solid absorber with no loss in IR-absorption efficiency. The support structure is mechanically robust and has a thermal conductance, G < 2 x 10(-11) W/K, which is four times smaller than previously achieved at 300 mK.

View Article and Find Full Text PDF

We describe a low-pass filter that provides high in-band transmittance and excellent rejection at ν > 100 cm(-1). The transmittance of the filter components was measured at liquid-helium temperatures from 10 to 10,000 cm(-1). The total transmittance is >50% for ν < 50 cm(-1) and is calculated to be <10(-9) for ν > 300 cm(-1).

View Article and Find Full Text PDF

We have developed an instrument for directly measuring the emissivity of reflective surfaces at near-millimeter wavelengths. The thermal emission of a test sample is compared with that of a reference surface, allowing the emissivity of the sample to be determined without heating. The emissivity of the reference surface is determined by one's heating the reference surface and measuring the increase in emission.

View Article and Find Full Text PDF

We developed a far-infrared Fabry-Perot filter constructed from a single silicon substrate. The limiting resolving power caused by beam divergence of a silicon-gap Fabry-Perot filter is approximately 10 times higher than that of a vacuum-gap Fabry-Perot filter because of the large index of refraction of silicon. The filter thus permits compact, high-throughput optical systems.

View Article and Find Full Text PDF

We report the design and testing of a compact system of baffles for cooled infrared telescopes. The baffle system consists of a reflecting forebaffle and a black aftbaffle and provides a high level of rejection of emission from off-axis sources. The forebaffle reflects radiation incident at angles greater than 40° off axis out of the telescope, thereby reducing the aperture heat load.

View Article and Find Full Text PDF