In a comparative study we investigated the performance characteristics of nine hollow-fibre oxygenators. In a clinical setting, 10 units of each type of oxygenator were tested for oxygen exchange, transoxygenator pressure drop, heat exchanger performance and blood trauma. The oxygenators included are Maxima PRF Plus, Affinity, Forte, Affinity NT, Quantum, Optima, Capiox 1.
View Article and Find Full Text PDFThe purpose of this study was to examine the effect of aging on brain metabolite concentrations, including N-acetyl aspartate (NAA), the major marker of neurones, using short echo proton spectroscopy. Single-voxel proton spectra (TE 30 msec, TR 2 seconds) were obtained from white and gray matter using automated software (PROBE, G.E.
View Article and Find Full Text PDFThe goal of this study was to establish the best approach for quantifying nuclear magnetic resonance (NMR) lines, that in the frequency domain are overlapping with broad, unwanted background features. To perform the quantitative data analysis in a controlled way, test signals were designed and utilised, derived from two different real-world in vivo nuclear magnetic resonance signals. One of the main conclusions of the study was that the quantification methods currently available to the biomedical research groups can deliver the correct values of the quantitative parameters, but that great care should be taken in using optimal input parameters for the computer programs concerned.
View Article and Find Full Text PDFThe objective of this study was first to determine whether three slowly growing early-generation murine transplantable tumours, the T40 fibrosarcoma, T115 mammary carcinoma and T237 lung carcinoma, exhibit patterns of energetics and blood flow during growth that are different from those of the faster growing RIF-1 fibrosarcoma. Serial measurements were made with 31P-magnetic resonance spectroscopy (MRS), relating to nutritive blood flow and 2H-magnetic resonance imaging (MRI), which is sensitive to both nutritive and large-vessel (non-nutritive) flow. All four tumour lines showed a decrease in betaNTP/Pi and pH with growth; however, each line showed a different pattern of blood flow that did not correlate with the decrease in energetics.
View Article and Find Full Text PDFShort echo time in vivo STEAM 1H MR spectra (4.7 T, TE = 16 ms) of normal rat brain were fitted in the time domain using a VARPRO-like algorithm called AMARES which allows an inclusion of a large amount of prior knowledge. The prior knowledge was derived from phantom spectra of pure metabolite solutions measured under the same experimental conditions as the in vivo spectra.
View Article and Find Full Text PDF