A two-color infrared interferometer has been developed for the investigation of high-density weakly ionized tantalum plasma in x-ray complexes based on linear induction accelerators (1.6 kA electron beam current, 4.6 MeV energy, and 100 ns pulse duration).
View Article and Find Full Text PDFThe dynamics of the diffraction peak shape during pulsed heat load on mosaic single-crystal tungsten were measured at the `Plasma' scattering station on the eighth beamline of the VEPP-4 synchrotron radiation source at the Budker Institute of Nuclear Physics. The observed evolution of the diffraction peak shape agrees with theoretical predictions based on calculations of deformation caused by pulsed heating. Three clearly distinguishable stages of the diffraction-peak evolution were found, correlating with the evolution of temperature and deformation distributions.
View Article and Find Full Text PDFRev Sci Instrum
February 2014
A 1000 keV, 5 MW, 1000 s neutral beam injector based on negative ions is being developed in the Budker Institute of Nuclear Physics, Novosibirsk in collaboration with Tri Alpha Energy, Inc. The innovative design of the injector features the spatially separated ion source and an electrostatic accelerator. Plasma or photon neutralizer and energy recuperation of the remaining ion species is employed in the injector to provide an overall energy efficiency of the system as high as 80%.
View Article and Find Full Text PDFOnderstepoort J Vet Res
June 2012
Electronic Integrated Disease Surveillance System (EIDSS) has been used to strengthen and support monitoring and prevention of dangerous diseases within One Health concept by integrating veterinary and human surveillance, passive and active approaches, case-based records including disease-specific clinical data based on standardised case definitions and aggregated data, laboratory data including sample tracking linked to each case and event with test results and epidemiological investigations. Information was collected and shared in secure way by different means: through the distributed nodes which are continuously synchronised amongst each other, through the web service, through the handheld devices. Electronic Integrated Disease Surveillance System provided near real time information flow that has been then disseminated to the appropriate organisations in a timely manner.
View Article and Find Full Text PDFInnovative facility for neutron capture therapy has been built at BINP. This facility is based on compact vacuum insulation tandem accelerator designed to produce proton current up to 10 mA. Epithermal neutrons are proposed to be generated by 1.
View Article and Find Full Text PDF