Publications by authors named "A Stare"

To make outdoor clothing water- or dirt-repellent, durable water-repellent (DWR) coatings based on side-chain fluorinated polymers (SFPs) are used. During use of outdoor clothing, per- and polyfluoroalkyl substances (PFASs) can be emitted from the DWR to the environment. In this study, the effects of aging, washing, and tumble drying on the concentration of extractable PFASs in the DWR of perfluorohexane-based short-chain SFPs (FC-6 chemistry) and of perfluorooctane-based long-chain SFPs (FC-8 chemistry) were assessed.

View Article and Find Full Text PDF

To assess the effects of weathering on per- and polyfluoroalkyl substances (PFASs) from durable water repellent (DWR) clothing, thirteen commercial textile samples were exposed to elevated ultra violet (UV) radiation, humidity, and temperature in an aging device for 300 h, which mimics the lifespan of outdoor clothing. Before and after aging, the textile samples were extracted and analysed for the ionic PFASs (perfluoroalkyl acids (PFAAs), perfluorooctane sulfonamide (FOSA)) and volatile PFASs (fluorotelomer alcohols (FTOHs), acrylates (FTACs) and methacrylates (FTMACs)). Results showed that weathering can have an effect on PFASs used in DWR of outdoor clothing, both on the PFAS profile and on the measured concentrations.

View Article and Find Full Text PDF

Fluorinated durable water repellent (DWR) agents are used to obtain water and stain repellent textiles. Due to the on-going phase-out of DWRs based on side-chain fluorinated polymers (SFP) with "long" perfluoroalkyl chains, the textile industry lacks suitable alternatives with comparable material characteristics. The constant development and optimization of SFPs for textile applications initiated more than half a century ago has resulted in a robust and very efficient DWR-technology and textiles with exceptional hydro- and oleo-phobic properties.

View Article and Find Full Text PDF

In this paper several control strategies for nitrogen removal are proposed and evaluated in a benchmark simulation model of an activated sludge process. The goal is to determine which control strategy delivers better performance with respect to plant operating costs. In the study, constant manipulated variables and various PI and feedforward control strategies are tested and compared with predictive control, which uses an ideal process model.

View Article and Find Full Text PDF

In the paper three linear aeration controllers that can be easily implemented are presented and evaluated on the activated sludge process pilot plant. Controllers differ according to the information that is used about the process, which can be oxygen in the last aerobic reactor, ammonia in the last aerobic reactor and ammonia in the influent. The aeration controllers that are addressed are: oxygen cascade PI controller, ammonia cascade PI controller and ammonia feedforward-cascade PI controller.

View Article and Find Full Text PDF