Publications by authors named "A M Rasmus"

We have developed a method to extract density fluctuation measurements from x-ray radiographs of high-energy density (HED) instability growth and turbulence experiments. We use this information to calculate density fluctuation statistics for constraining the performance of turbulent mix models in HED systems. The density calculation combines image filtering, removal of systemic effects such as backlighter variation, calculation of transmission across multiple materials, and use of tracer materials to generate an approximate single-material density field.

View Article and Find Full Text PDF

We describe the details of a digital holographic microscopy diagnostic capable of quantifying both the topography and velocity of a km/s object with adjustable temporal sensitivity. This technique involves spatially multiplexing a double pulse reflected from a target with reference beams of precisely known temporal separation.

View Article and Find Full Text PDF

Noise is a consistent problem for x-ray transmission images of High-Energy-Density (HED) experiments because it can significantly affect the accuracy of inferring quantitative physical properties from these images. We consider experiments that use x-ray area backlighting to image a thin layer of opaque material within a physics package to observe its hydrodynamic evolution. The spatial variance of the x-ray transmission across the system due to changing opacity serves as an analog for measuring density in this evolving layer.

View Article and Find Full Text PDF

Metabolic syndrome (MetS) or otherwise insulin resistance (IR) is described as a cluster of several commonly occurring disorders, including abdominal obesity; lipids disorders, such as hypertriglyceridemia; and low levels of high-density-lipoprotein cholesterol (HDL-C), hypertension (≥130/85 mmHg), and carbohydrates disorders, such as impaired fasting glucose or diabetes mellitus type 2. Type 2 diabetes (T2DM) constitutes insulin resistance, which is a strong risk factor for strokes. Patients with MetS are often prone to cognitive decline.

View Article and Find Full Text PDF

In this paper, we report on a crystal based x-ray imaging system fielded at the OMEGA EP laser facility. This new system has a pointing accuracy of +/100 μm, a temporal resolution down to 100 ps (depending on backlighter characteristics), variable magnification, and a spatial resolution of 21.9 µm at the object plane at a magnification of 15×.