Aim: The aim of this study was to evaluate in vivo the effectiveness of scaling and root planing of new oscillating instruments (Periosonic) using a sonic handpiece compared to hand curettes with a split mouth design after 2 months.

Methods: 11 patients with adult periodontitis participated in this study. Plaque index (PII) (O'Leary), bleeding on probing (BOP), probing pocket depth (PPD), recession (REC) and clinical attachment level (CAL) were recorded at baseline and 2 months after treatment.

View Article and Find Full Text PDF

Aims: This study investigated the loss of tooth substance (microg) by means of liquid scintillation in combination with profilometric and SEM analyses in order to evaluate the roughness and morphological changes of the root surface before and after instrumentation.

Method: 40 polished and irradiated bovine root surfaces were scaled in vitro while covered with 50 ml distilled water using a sonic prototype (Periosonic 1/2), a magnetostrictive ultrasonic (Cavitron with Slimline inserts) scaler and a hand curette. Pressures were applied for the Periosonic, Cavitron and hand curette at 500, 500 and 30 g respectively, for 30-s intervals, up to 120 s.

View Article and Find Full Text PDF

Background: The effects of magnetostrictive ultrasonic instruments and piezoelectric ultrasonic instruments on tooth surfaces seem to differ with regards to root debridement.

Aim: The purpose of this study was to compare a magnetostrictive ultrasonic scaling instrument with a piezoelectric ultrasonic scaling instrument and a hand curette regarding time taken, calculus removal, tooth surface roughness (Ra), and SEM examination before and after instrumentation.

Methods: 30 extracted human teeth with subgingival calculus were assigned to one of three treatment groups (n=10).

View Article and Find Full Text PDF

Sodium hypochlorite is a major irrigant in endodontics, and nickel-titanium instruments are gaining in popularity. This paper investigated the corrosion of nickel-titanium Lightspeed instruments in 1% and 5% NaOCl solutions. The instruments were immersed in ultrasonicated NaOCl solutions for varying times up to 1 h.

View Article and Find Full Text PDF

1. Plasma concentrations of acitretin and its metabolite (13-cis acitretin) were measured in six patients on haemodialysis and six subjects without renal failure following a single oral dose of 50 mg of acitretin. 2.

View Article and Find Full Text PDF