Publications by authors named "A Hellerbach"

Introduction: Photon-counting detector computed tomography (PCD-CT) represents the next generation of CT technology, offering enhanced capabilities for detecting the orientation of directional leads in deep brain stimulation (DBS). This study aims to refine PCD-CT-based lead orientation determination using an automated method applicable to devices from various manufacturers, addressing current methodological limitations and improving neurosurgical precision.

Methods: An automated method was developed to ascertain the orientation of directional DBS leads using PCD-CT data and grayscale model fitting for devices from Boston Scientific, Medtronic, and Abbott.

View Article and Find Full Text PDF

Introduction: With recent advancements in deep brain stimulation (DBS), directional leads featuring segmented contacts have been introduced, allowing for targeted stimulation of specific brain regions. Given that manufacturers employ diverse markers for lead orientation, our investigation focuses on the adaptability of the 2017 techniques proposed by the Cologne research group for lead orientation determination.

Methods: We tailored the two separate 2D and 3D X-ray-based techniques published in 2017 and originally developed for C-shaped markers, to the dual-marker of the Medtronic SenSight™ lead.

View Article and Find Full Text PDF

(1) Background: Transient increase in volume of vestibular schwannomas (VS) after stereotactic radiosurgery (SRS) is common and complicates differentiation between treatment-related changes (pseudoprogression, PP) and tumor recurrence (progressive disease, PD). (2) Methods: Patients with unilateral VS (n = 63) underwent single fraction robotic-guided SRS. Volume changes were classified according to existing RANO criteria.

View Article and Find Full Text PDF

Purpose: In robotic stereotactic radiosurgery (SRS), optimal selection of collimators from a set of fixed cones must be determined manually by trial and error. A unique and uniformly scaled metric to characterize plan quality could help identify Pareto-efficient treatment plans.

Methods: The concept of dose-area product (DAP) was used to define a measure (DAP) of the targeting efficiency of a set of beams by relating the integral DAP of the beams to the mean dose achieved in the target volume.

View Article and Find Full Text PDF

Purpose: In stereotactic radiosurgery (SRS), prescription isodoses and resulting dose homogeneities vary widely across different platforms and clinical entities. Our goal was to investigate the physical limitations of generating dose distributions with an intended level of homogeneity in robotic SRS.

Methods: Treatment plans for non-isocentric irradiation of 4 spherical phantom targets (volume 0.

View Article and Find Full Text PDF