Publications by authors named "A Geha"

The CarboMedics Top Hat supraannular aortic valve provides an orifice-to-annulus ratio of 1:1 in most patients, and enhances patient outcomes. This study compared the midterm echocardiographic parameters of 52 patients undergoing aortic valve replacement with a Top Hat valve with those in other studies of Top Hat or CarboMedics intraannular valves. Echocardiography was performed 6-48 months after surgery with Top Hat sizes 21-27.

View Article and Find Full Text PDF

Background: Unroofing of anomalous coronary artery originating from the opposite sinus of Valsalva has become the procedure of choice for this congenital lesion, with surgery performed in children as young as two years old. An increasing number of this anomaly is diagnosed in infancy with no clear indication whether surgical repair should be done in this age group. This paper reviews our experience with this anomaly, and focuses on its surgical management in infants.

View Article and Find Full Text PDF

Warfarin and heparin have formed the mainstay in the prophylaxis of deep vein thrombosis (DVT), stroke prevention in atrial fibrillation, and treatment of thromboembolic disease (TED). However, these choices are hampered by difficult administration, interactions with other medications, side effect profile, and limited indications for treatment. Anti-factor Xa (anti-Xa) inhibitors have already entered the drug market with the drug Fondaparinux being the first anti-Xa inhibitor to be approved for use in the U.

View Article and Find Full Text PDF

Atrial fibrillation (AF) affects several million patients worldwide and is associated with a number of heart conditions, particularly coronary artery disease, rheumatic heart disease, hypertension, and congestive heart failure. The treatment of AF and its complications is quite costly. Atrial fibrillation usually results from multiple macro-re-entrant circuits in the left atrium.

View Article and Find Full Text PDF

Background And Aim Of The Study: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area is less than that of a normal valve. It is suggested that the ability to implant Top Hat valves having greater size, relative to standard intra-annular valves, may currently be under-utilized.