This paper reports conclusions from a recent study completed for the Water Research Foundation and the State of California to offer guidance on UV-chlorine advanced oxidation for potable water reuse. The fundamentals of UV-chlorine advanced oxidation are discussed, and lessons learned from some of the early adopters of this technology are presented. Important highlights include the significant impact of ammonia and chloramines on UV-chlorine treatment, challenges associated with predicting UV-chlorine performance due to complex photochemistry, and an ongoing need to monitor potential byproducts and transformation products when employing any form of advanced oxidation for potable reuse.
View Article and Find Full Text PDFThe capture zone or contributing area of a ground water extraction well can be defined as that portion of the aquifer from which the well draws its water. Accurate delineation of capture zones is important in many ground water remediation applications and in the definition of wellhead protection areas. Their mathematical delineation is often simplified by using quasi-steady-state models based on time-weighted average pumping rates and background hydraulic gradients.
View Article and Find Full Text PDF